Page 2 - SAFETY GUIDELINES - DEFINITIONS; understand. This information relates to protecting; IMPORTANT SAFETY INSTRUCTIONS
2- ENG A10260 SAFETY GUIDELINES - DEFINITIONS Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Indicates a potentially hazardous situa...
Page 3 - Save these instructions; HAZARD; WARNING: Risk of explosion or fire
3- ENG A10260 IMPORTANT SAFETY INSTRUCTIONS Save these instructions Improper operation or maintenance of this product could result in serious injury and property damage. Read and understand all warnings and operation instructions before using this equipment. HAZARD WARNING: Risk of explosion or fire...
Page 6 - WARNING: Risk of Burns; WARNING: Risk from Moving Parts
6- ENG A10260 WARNING: Risk of Burns Touching exposed metal such as the compressor head or outlet tubes, can result in serious burns. Never touch any exposed metal parts on compressor during or immediately after operation. Compressor will remain hot for several minutes after operation. Do not reach ...
Page 7 - WARNING: Risk of Unsafe Operation; SAVE THESE INSTRUCTIONS
7- ENG A10260 Review and understand all instructions and warnings in this manual. Become familiar with the operation and controls of the air compressor. Keep operating area clear of all persons, pets, and obstacles. Keep children away from the air compressor at all times . Do not operate the product...
Page 8 - CFM
8- ENG A10260 GLOSSARY DUTY CYCLE SPECIFICATIONS Accessories for this unit are available at the store the unit was purchased. ACCESSORIES Model No. C5510 Running Horsepower 1.9 Bore 2-7/8" Stroke 2" Voltage-Single Phase 120/240 Minimum Branch Circuit Requirement 20 amps Fuse Type Time Delay ...
Page 9 - To Install Handle; Remove handle grip from soapy water and slide onto handle.; ASSEMBLY; Unpacking; Remove unit from carton and discard all packaging.; Tools Required for Assembly
9- ENG A10260 To Install Handle The wheels and handle do not provide adequate clearance, stability, or support for pulling the unit up and down stairs or steps. The unit must be lifted or pushed up a ramp. Do not lift the unit by the manifold assembly, the unit could be damaged. 1. To make installat...
Page 10 - Attach wheels with shoulder bolts and nuts; Wheel; Rubber Foot
10- ENG A10260 Assemble Rubber Feet 1. Attach rubber feet with the screws, washers, and nuts provided as shown. 2. Tighten securely. To Assemble Wheels It will be necessary to brace or support one side of the unit when installing the wheels because the compressor will have a tendency to tip. 1. Atta...
Page 11 - To Add Oil To Pump
11- ENG A10260 To Add Oil To Pump Compressors are shipped without oil. A small amount of oil may be present in the pump upon receipt of the air compressor. This is due to plant testing and does not mean the pump contains oil. Do not attempt to operate this air compressor without first adding oil to ...
Page 12 - GROUNDING INSTRUCTIONS; DO NOT USE AN; INSTALLATION; HOW TO SET UP YOUR UNIT; Location of the Air Compressor; DO NOT
12- ENG A10260 GROUNDING INSTRUCTIONS Risk of Electrical Shock. In the event of a short circuit, grounding reduces the risk of shock by providing an escape wire for the electric current. This air compressor must be properly grounded. The portable air compressor is equipped with a cord having a groun...
Page 14 - Description of Operation; Outlet Pressure Gauge:; OPERATION; Know Your Air Compressor
14- ENG A10260 Description of Operation Become familiar with these controls before operating the unit. On/Auto/Off Lever : Turn this switch to "On/Auto" to provide automatic power to the pressure switch and "Off" to remove power at the end of each use. Pressure Switch: The pressure s...
Page 15 - Pressure Release Valve:; How to Use Your Unit; Before Starting; Risk of Unsafe Operation. Serious damage may result if
15- ENG A10260 Drain Valve: The drain valve is located at the base of the air tank and is used to drain condensation at the end of each use. Check Valve: When the air compressor is operating, the check valve is "open", allowing compressed air to enter the air tank. When the air compressor re...
Page 16 - Risk of Bursting. Too much air pressure causes a
16- ENG A10260 How to Start: 1. Turn the On/Auto/Off lever to "On/Auto" and allow tank pressure to build. Motor will stop when tank pressure reaches "cut-out" pressure. 2. Pull the regulator knob out and turn clockwise to increase pressure. When the desired pressure is reached push k...
Page 17 - MAINTENANCE; Customer Responsibilities; - more frequent in dusty or humid conditions; Risk of Unsafe Operation. Unit cycles automatically when; To Check Safety Valve; Risk of Bursting. If the safety valve does not work; operate smoothly, it must be replaced with the same type of valve.
17- ENG A10260 MAINTENANCE Customer Responsibilities Daily or after each use Before each use ● ● ● ● Every 8 hours Every 40 hours Every 100 hours Yearly Every 160 hours ● ● 1 1- more frequent in dusty or humid conditions Check Safety ValveDrain TankOil LeaksCheck OilChange Oil Air Filter NOTE: See &...
Page 18 - Checking
18- ENG A10260 To Drain Tank NOTE: Operation of the air compressor will cause condensation to build up in the air tank. Always drain tank on a washable surface or in a suitable container to prevent damaging or staining surfaces.1. Set the On/Auto/Off lever to "Off".2. Pull the regulator knob...
Page 21 - SERVICE AND ADJUSTMENTS; To Replace or Clean Check Valve; Note; Screwdriver; Outlet Tube
21- ENG A10260 SERVICE AND ADJUSTMENTS To Replace or Clean Check Valve 1. Release all air pressure from air tank. See "To Drain Tank" in the "Maintenance" section. 2. Unplug air compressor.3. Using an adjustable wrench loosen outlet tube nut at air tank and pump. Carefully move outle...
Page 22 - To Replace Regulator; NOTE
22- ENG A10260 To Replace Regulator 1. Release all air pressure from air tank. See "To Drain Tank" in the "Maintenance" section. 2. Set the On/Auto/Off lever to "Off" and unplug unit. 3. Using an adjustable wrench remove the outlet pressure gauge and quick connect from the re...
Page 23 - STORAGE; scheduled maintenance as necessary.; causing a risk of air tank rupture.; After the water has been drained, close the drain or drain valve.
23- ENG A10260 STORAGE Before you store the air compressor, make sure you do the following:1. Review the "Maintenance" section on the preceding pages and perform scheduled maintenance as necessary. 2. Set the On/Auto/Off lever to "Off" and unplug unit.3. Turn the regulator counterclo...
Page 24 - TROUBLESHOOTING; PROBLEM; Risk of Unsafe Operation. Unit cycles automatically
24- ENG A10260 TROUBLESHOOTING PROBLEM CAUSE CORRECTION Pressure switch does not shut off motor when compressor reaches "cut-out" pressure. Pressure switch "cut-out" too high. Move On/Auto/Off lever to the "Off" position, if the unit does not shut off contact a Trained Servic...
Page 25 - Check valve restricted.
25- ENG A10260 PROBLEM CAUSE CORRECTION Compressor is not supplying enough air to operate accessories. Prolonged excessive use of air.Compressor is not large enough for air requirement. Hole in hose. Check valve restricted. Air leaks. Restricted air intake filter. Decrease amount of air usage. Check...
Page 27 - Knocking Noise. Possible defect in safety
27- ENG A10260 PROBLEM CAUSE CORRECTION Knocking Noise. Possible defect in safety valve. Operate safety valve manually by pulling on ring. If valve still leaks, it should be replaced. Loose pulley. Tighten pulley set screw, see Parts manual for torque specifications. Compressor mounting screws loose...
Page 28 - LIMITED WARRANTY
28- ENG A10260 LIMITED WARRANTY PORTER-CABLE CORPORATION warrants to the original purchaser that all products covered under this warranty are free from defects in material and workmanship. Products covered under this warranty include air compressors, air tools, service parts, pressure washers, and g...