Page 3 - Table of Contents
Table of Contents Introduction ................................................................................................................................................................... 1 Definitions...............................................................................................
Page 5 - VGA multi-scan Monitors; Compatibility
1 Introduction The NTI ST-nXm-U-HD (also known as NODEMUX-HD) is a multi-user / Universal Multi-Platform Matrix KVM switch, (n= numberof users, m= number of CPUs) with high density construction to require less rack space. It allows multiple users, up to 4, each witha keyboard, monitor, and mouse, to...
Page 6 - SUN CPU to Switch; OR; where; Keypad buttons for user control over switch functions; Features and Functions; N T I
2 Interface cables and adapters are not included and must be purchased separately . A cable for each CPU being connected to the switch: PS/2 CPU to Switch • VMTINT-xx-MM for video, keyboard and mouse interface OR SUN CPU to Switch • SMTINT-xx-MM for video, keyboard and mouse interface • 13W3M-15HDF ...
Page 7 - Additional Features
3 Additional Features • Users can work individually or share the same CPU. • Up to n users can work with m CPUs where n and m are the switch size acquired. • High density (similar to SCSI) input and output ports that interface cables plug into adapt to PS/2 and SUN platform devices. • Power cycle ci...
Page 8 - for more information.; Figure 1- Connect devices to switch using interface cables; Installation; H i g h D e n s i t y
4 Installation Turn OFF power to all CPUs that will be connected to the NTI ST-nXm-U-HD switch before connecting or disconnecting anycables. 1. If using RS-232 Control see RS-232 section for more information. 2. Connect the monitors to the 15HD female connector ends of the VMTINT-xx or SMTINT-xx cab...
Page 9 - Figure 2- Connect CPUs to switch using interface cables; Plug the NTI Switch into an AC power outlet.
5 Figure 2- Connect CPUs to switch using interface cables 7. Plug the NTI Switch into an AC power outlet. 8. Turn ON power to the NTI Switch, the LCD should illuminate. 9. Turn ON power to any or all CPUs connected to the NTI Switch. NOTE: The order in which the CPUs and switch are turned ON does no...
Page 10 - Key; USR: 1 2 3 4
6 Using the ST-nXm-U-HD Switch Basic Operation This unit enables any user to access any CPU at any time with no restrictions or limitations. Users can even share a CPU andwork on the same project – each from their own console. Resolution is supported through 1900x1200 with no degradation –guaranteed...
Page 11 - The administrator; The administrator will; The factory administrator login settings are:; The user will; OSD Control
7 OSD Control OSD superimposes a menu system on the user’s video screen with a list of all connected CPUs. OSD allows CPUs to be named(with up to 12 character names). OSD then allows selection of CPUs by that name. Connected CPUs can be listed by name or byport number. OSD Search Mode enables the us...
Page 12 - User Login Mode; Submit user name/password; Additional OSD Modes Available With Security; Disable security; Shift; or; Esc
8 User Login Mode User Login Mode requires a user to login with a user name and password from the list created by the administrator. With securityenabled, the user will be locked to the current CPU and the login screen will remain on the monitor until the user logs in. Function: Keystroke: Add a cha...
Page 13 - Figure 4- Administration Mode Menu; Enter User Name List Mode; Port Status Mode; Figure 5- Administrator password menu; Tab
9 Figure 4- Administration Mode Menu Function: Keystroke: Enter User Name List Mode Selects the idle time in minutes Exit Administration Mode andreturn to previous mode Port Status Mode Port Status mode enables the administrator to view extended status information about the port selected in Administ...
Page 14 - User Name List; Return to Administration Mode; Figure 6- User Name List; System Access List
10 Administrator Password (cont'd)Function: Keystroke: Save new password. (Theadministrator will be promptedfor a Yes or No confirmation) Return to Administration Mode User Name List To enter the User Name List press <U> from the Administration Mode menu. The User Name List (see Fig. 6) enable...
Page 15 - Figure 7- Command Mode main menu; Ctrl
11 User Access Functions Command Mode In order to control the switch with the keyboard, Command Mode must be enabled. To enable Command Mode from the keyboard: Press All the status lights on the keyboard will illuminate to indicate that Command Mode is enabled. At this point, the Command Modemenu wi...
Page 16 - Scan Mode; Enter
12 Command Mode (Cont'd)Function: Keystroke: Enter Edit Mode(Only available if administratoris logged in) Selects scan time in seconds Enter Maintenance Mode Display Help Menu Select a specific port Select the first port on the switch Select the last port on the switch Enter Search Mode, add a chara...
Page 17 - Edit Mode; Select the first port on the switch; Search Mode; Select the previous port
13 Edit Mode To activate Edit Mode press <Ctrl> + <E> from the Command Mode menu. Edit Mode allows only the administrator to modify the names of the CPUs connected to the switch. Names of CPUs can be up to12 characters in length. Characters typed can be upper or lower case. After changes...
Page 18 - Maintenance Mode; Keystroke:
14 Search Mode (cont'd)Function: Keystroke: Select the next port Add a character to the searchstring and select the bestmatching CPU name Exit Search Mode, return toCommand mode Maintenance Mode To enter Maintenance Mode (see Fig. 8) press <Ctrl>+<M> from the Command Mode menu. Maintenan...
Page 19 - Return to Command Mode; Help Mode; WINXX; Compose; (Only displayed when security is active); Keyboards
15 Maintenance Mode (Cont'd)Function: Keystroke: Log current user out and returnto User Login Mode. Save OSD window parametersfor the port Return to Command Mode NOTE: Based on different scan rates, the OSD window may appear in different areas of the monitor as different CPUports are selected. The M...
Page 20 - Sun Extras; T y p i c a l W i n d o w s K e y b o a r d
16 SUN’s Startup Keys With a Sun CPU attached to the switch, the following emergency startup keys are supported: Key Function Stop Bypass POST Stop-A Abort Stop-D Enter diagnostic mode Stop-F Enter Forth on TTYA instead of probing Stop-N Reset NVRAM contents to default values This switch will also s...
Page 21 - Remote Connection; The pin outs for the DB-9 connector on the unit are as follows:; PIN; none; Baud Rate; Figure 10- RS232 Connections for Daisy-chain; Command Protocol
17 RS232 Control Remote Connection The RS232 Interface is designed to control the switch via serial (RS232) daisy chain connection from any CPU or other controllerwith an RS232 communications port. There is, however, a restriction that must be followed: A program must be used that will send an entir...
Page 22 - RS232 INTERFACE TEST PROGRAM DESCRIPTION; Main Options
18 CS - change single USER channel FORMAT: CS AA,XX,YY<CR>CS = "change single USER" command followed by at least one spaceAA = unit addressXX = CPU to connectYY = USER to change RESPONSE: *<CR> (command received and executed OK) ?<CR> (syntax or transmission error occurred)...
Page 23 - SET OPTIONS
19 9) Read Connection for KVM Output/User - read what input is connected to the specified output (KVM ports only) a) Read Connection for Audio Output/User - read what input is connected to the specified output (Audio ports only) b) Read Mute Status and Volume for Audio Output/User - read the volume ...
Page 24 - Matrix Switcher's Control Program For Windows 9X, NT, and 2000; To install the Matrix Switcher's Control Program; SETUP; Follow the instructions on the screen; START; on; MSCP Help; This feature ensures constant power to the unit since; Figure 11- Dual Redundant Power Supply Option; Dual Redundant Power Supply; F e m a l e
20 Matrix Switcher's Control Program For Windows 9X, NT, and 2000 The Matrix Switcher's Control Program is an easy and powerful graphical program that controls NTI matrix switches through anRS232 interface. The Matrix Switcher's Control Program is on a 3-1/4" floppy disc packaged with the ST-nXm...
Page 25 - ST- MX Expansion Units; WARNING; DEFAULT VALUE; ST-MX Expansion Units; APPENDIX
21 ST- MX Expansion Units In order to be able to expand the current ST-nXm-U-HD product or go beyond the 8/16 CPU limit on the ST-nXm-U-HD, the ST-MX expansion unit can be used to combine, or bank, multiple switches together to be controlled from one central workstation. Each user that desires to us...
Page 26 - NTI; Rack
22 Appendix B- General InformationDESCRIPTION SPECIFICATION Dimensions 19"W x 10" D x 1.75" H Operating temperature 0 ° C - 55 ° C (32 ° F - 131 ° F) Power requirements 120 or 240VAC @ 50 or 60Hz Video bandwidth 200 MHz (without cables) Video sync TTL Chassis material Aluminum Appendix C...