The following information is updated from the enclosed Installation Instructions.
Table 2, Page 4: Added M1SB 066 and M1BB 066 furnace models.
Furnace
Input
Output
Orifice
No
E.S.P.
Pilot
Ignitor
Comb.
Motor
_./C Bead
ModeINo
MBtu/h
MBtu/h
Nat.
LP
In WC
Burner
Direct
Blower
Hp
Tons
M1GH
056
56
45
29
45
0.3
x
1/8
2*
M1GB
056
56
45
29
45
0.3
x
1/4
3
M1GC
056
56
45
29
45
0.3
x
1/2
4
M1GD
056
56
45
29
45
0.3
x
3/4
5
M1GH
070
70
57
24
42
0.3
x
1/5
2V2"
M1GB
070
70
57
24
42
0.3
x
1/4
3
M 1GC
070
70
57
24
42
0.3
x
1/2
4
M1GD
070
70
57
24
42
0.3
x
3/4
5
M1GH
077
77
62
21
40
0.3
x
x
1/4
3*
M1GB
077
77
62
21
40
0.3
x
x
1/4
3
M1GC
077
77
62
21
40
0.3
x
x
1/2
4
M1GD
077
77
62
21
40
0.3
x
x
3/4
5
M1GH
090
90
72
17
36
0.3
x
x
1/4
3*
M1GB
090
90
72
17
36
0.3
x
x
1/4
3
M1GC
090
90
72
17
36
0.3
x
x
1/2
4
M 1GD
090
90
72
17
36
0.3
x
x
3/4
5
M1MA
056
56
46
29
45
0.3
x
x
1/8
2
M1MB
056
56
46
29
45
0.3
x
x
1/4
3
M1MC
056
56
46
29
45
0.3
x
x
1/2
4
M1MD
056
56
46
29
45
0.3
x
x
3/4
5
M1MA
070
70
57
24
42
0.3
x
x
1/5
2V2
M1MB
070
70
57
24
42
0.3
x
x
1/4
3
M 1MC 070
70
57
24
42
0.3
x
x
1/2
4
M1MD
070
70
57
24
42
0.3
x
x
3/4
5
M1MB
077
77
62
21
40
0.3
x
x
1/4
3
M1MC
077
77
62
21
40
0.3
x
x
1/2
4
M1MD
077
77
62
21
40
0.3
x
x
3/4
5
M1MB
090
90
72
17
36
0.3
x
x
1/4
3
M1MC
090
90
72
17
36
0.3
x
x
1/2
4
M 1MD 090
90
72
17
36
0.3
x
x
3/4
5
M1BA
066
66
53
26
43
0.3
x
x
1/5
2V2
M1BB
066
66
53
26
43
0.3
x
x
1/4
3
M1BC
066
66
53
26
43
0.3
x
x
1/2
4
M1BB
086
86
68
18
37
0.3
x
x
1/4
3
M1BC
086
86
68
18
37
0.3
x
x
1/2
4
M1SA
066
66
54
.50 Gph
0.3
x
Burner
Model
1/5
2V2
M1SB
066
66
54
.50 Gph
0.3
x
AF-IO
Nozzle
1/4
3
M1SC
066
66
54
.50 Gph
0.3
x
1/2
4
M1SB
086
86
71
.65 Gph
0.3
x
Spray
Angle
1/4
3
M1SC
086
86
71
.65 Gph
0.3
x
80 ° A
1/2
4
Electrical
Supply-
120 volts, 60HZ, 1 Ph.
Fuse or Breaker
- 15 amps
Temperature
Rise - 45 ° to 75°F
High Altitude - See Table 11. For Canadian
High Altitude (2,000' to 4,500'),
reduce the
gas manifold
pressure
to 3.0" W.C. for
natural gas and to 8" W.C. for LP gas.
Thermostat
Circuit - 24 volts, 60HZ, 30 vac
Normal Anticipator
Setting - 0.4
Manifold Pressure
- Natural Gas: 3.5" w.c.
LP Gas: 10" w.c.
*Blower
capacity only - needs relay box for AC
Table 2. IVll Furnace
Specifications
Table 9, Page 25: Factory combustion
air settings
Factory Combustion
Air Settings
M1 B* - 066 = 3.5
M1 B* - 086 = 4.0
M1 S* - 066 = 3.0
MlS* - 086 = 5.5
Table 9.
7085710
Specifications
and illustrations subject to change
without
notice
and without incurring
oHigations.
O'Fallon,
MO
__
708571
0
Pdnted in U.S.A. (05/06)
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Was this manual helpful?
About this manual
- Brand
- Nordyne
- Model
- M1SC086
- Document type
- Installation Manual
- Language(s)
- English
- Pages
- 1
- File size
- 107 KB
- Format