Nikon 55i - Manual
Nikon 55i – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 3 – Refined stage; Refocusing stage; New ergonomic tube; ° to 30° and the eyepieces can be
- Page 4 – CF1 60—tried and tested infinity optics; flip of a switch, utilizing a motorized mechanism.; DSC port enables digital imaging in comfort; Change between; Wide variety of tools
- Page 5 – Ergonomic tube
- Page 6 – System Diagram; Digital microscope; digital; Advanced research microscope
- Page 7 – WARNING; NIKON CORPORATION; NIKON INSTRUMENTS INC.; Dimensional Diagrams; Configured with binocular tube B; Specifications; Main body; ECLIPSE i-Series Website
En
This brochure is printed on recycled paper made from 40% used material.
WARNING
TO ENSURE CORRECT USAGE, READ THE CORRESPONDING MANUALS
CAREFULLY BEFORE USING YOUR EQUIPMENT.
Specifications and equipment are subject to change without any notice or obligation
on the part of the manufacturer. December 2003.
©2003 NIKON CORPORATION
NIKON CORPORATION
Yokohama Plant
NIKON CORPORATION
Instruments Company
ISO 9001
Accredited by the
Dutch Council for
Accreditation
ISO 14001
Printed in Japan (0312-13)T
Code No. 2CE-MSHH-1
www.nikon.com/
Fuji Bldg., 2-3, Marunouchi 3-chome, Chiyoda-ku,
Tokyo 100-8331, Japan
NIKON CORPORATION
NIKON INSTECH CO., LTD.
Parale Mitsui Bldg., 8, Higashida-cho, Kawasaki-ku,
Kawasaki, Kanagawa 210-0005, Japan
phone: +81-44-223-2167 fax: +81-44-223-2182
www.nikon-instruments.jp/eng/
www.i-series.com
NIKON INSTRUMENTS (SHANGHAI) CO., LTD.
CHINA phone: +86-21-5058-5055 fax: +86-21-5058-5060
NIKON SINGAPORE PTE LTD
SINGAPORE phone: +65-6559-3618 fax: +65-6559-3668
NIKON MALAYSIA SDN. BHD.
MALAYSIA phone: +60-3-78763887 fax: +60-3-78763387
NIKON INSTRUMENTS EUROPE B.V.
P.O. Box 222, 1170 AE Badhoevedorp, The Netherlands
phone: +31-20-44-96-222 fax: +31-20-44-96-298
http://www.nikon-instruments.com/
NIKON FRANCE S.A.
FRANCE phone: +33-1-45-16-45-16 fax: +33-1-45-16-00-33
NIKON GMBH
GERMANY phone: +49-211-9414-0 fax: +49-211-9414-322
NIKON INSTRUMENTS S.p.A.
ITALY phone: + 39-55-3009601 fax: + 39-55-300993
NIKON AG
SWITZERLAND phone: +41-43-277-2860 fax: +41-43-277-2861
NIKON UK LTD.
UNITED KINGDOM phone: +44-20-8541-4440 fax: +44-20-8541-4584
NIKON INSTRUMENTS INC.
1300 Walt Whitman Road, Melville, N.Y. 11747-3064, U.S.A.
phone: +1-631-547-8500; +1-800-52-NIKON (within the U.S.A.only) fax: +1-631-547-0306
http://www.nikonusa.com/
NIKON CANADA INC.
CANADA phone: +1-905-625-9910 fax: +1-905-625-0103
* Monitor images are simulated.
Company names and product names appearing in this brochure are their registered trademarks or trademarks.
Clinical & Laboratory Microscopes ECLIPSE 50i/55i
. . . magine microscopy in perfect comfort
/
/
I
O
FIL
200
330
60
404
208
60
I
O
FIL
486
330
200
208
Dimensional Diagrams
Configured with binocular tube B
Configured with ergonomic tube
Unit: mm
Specifications
Main body
50i
55i
Magnification
10 –1500X
Optical system
CFI60 Infinity Optical System
Coarse/fine focusing
Fine: 0.1mm per rotation, Coarse: 13.8mm per rotation, Minimum reading: 1 micron
Coarse motion torque adjustable, Refocusing function (with stopper)
Illumination
6V-30W halogen lamp
White LED array
100-240V (worldwide voltage)
AC adapter (100-240V) or optional lithium battery (7.4V)
Built-in filter
ND8
LA60 color balance filter
Eyepiece tube
Binocular tube B (for F.O.V. 22mm)
Trinocular tube "F" UW (for F.O.V. 22mm/25mm, observation/photo: 100/0, 0/100)
Trinocular tube "T" UW (for F.O.V. 22mm/25mm, observation/photo: 100/0, 20/80, 0/100)
Ergonomic binocular tube (for F.O.V. 22mm, inclination:10-30°, extension: 40mm); DSC port: 100/0, 50/50 (optional)
Eyepiece lens
10X (F.O.V.
:
22mm), 10X M photo mask (F.O.V.: 25mm), 12.5X (F.O.V.
:
16mm), 15X (F.O.V.
:
14.5mm),
UW 10X (F.O.V.
:
25mm), UW 10X M photo mask (F.O.V.
:
25mm)
Nosepiece
Sextuple nosepiece
Ergo-View cytodiagnostic unit (Motorized changeover 10X to 40X with hand switch, Stamp type marking
—
Automatic illumination adjustment with Ergo-View
Stage
Super-hard Alumite coated surface, Stay-in-position stage handle, Stage handle height and tension adjustable
Rectangular 159mm X 243mm surface stage, 78mm X 54mm cross travel (x-y movement)
1-slide or 2-slide specimen holder available (option)
Condenser focusing stroke
27mm
Intermediate accessories
Epi-fluorescence illuminator (4 filter positions), Magnification module, Eye-level riser, Double port
Teaching head
—
Observation method
Brightfield, Epi-fluorescence
Darkfield, Phase contrast, Simple polarizing
—
ECLIPSE i-Series Website
www.nikon-i.com
Please contact Nikon for a handy pamphlet listing compatible
accessories, including objectives and epi-fluorescence filters.
Nikon has reduced the amount of chromium, cadmium and lead used in the Eclipse-i Series
to an absolute minimum to diminish its environmental impact.
Microscopy images courtesy of :
1
Nihon University Itabashi Hospital
2
Naoyuki Miyokawa, M.D., Ph.D., Associate
Professor, Dept. of Surgical Pathology,
Asahikawa Medical College Hospital.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
5 4 4 . . . in harmony with you Cool illumination (55i) Utilizing white LED illumination, the 55i isan ideal choice for brightfield applications.As the color temperature does not changeeven when the brightness is altered,adjusting the color balance filter or voltageis no longer necessary. And becaus...
7 6 . . . in harmony with your vision CF1 60—tried and tested infinity optics Highly acclaimed optics combine the CF design with infinity optics and utilize a60mm parfocal distance, resulting in longer working distances and high N.A.’s,while producing crisp, clear images with minimal flare. The CF1 ...
9 8 . . . in harmony with your needs Pathology tests As the 55i model uses white LED illumination, it can maintain thesame color temperature even if the brightness is changed.Observations extending to many hours can be carried out in anatural posture, without physical strain because an ergonomic tub...