Description
The ST Series Selectronic Tattletale
annunciators are a simple and inexpensive
answer to your remote alarm annunciator
needs. Basic models
ST5AS and ST10AS
are general purpose alarms suitable for a
variety of applications. Model
ST8
gives first
out annunciation of fault. Model
STA16
is
designed for generator set applications and
can be configured to meet NFPA
requirements for standby generators.
These compact Tattletale annunciators tell
you by a flashing LED which variable
malfunctioned. Many feature a pulsating
Mini-Siren to audibly alert you to the
malfunction. The audible alarm is silenced
by depressing the Alarm Silence push
button, but the visual signal remains in
operation until the fault is corrected and the
contacts are cleared.
A test push button allows you to test all
alarm LEDs. Because LEDs are solid state,
cold light, electronic devices, they don’t
burn out as incandescent light bulbs do.
Basic models accept 8-32 VAC or 8-40 VDC
input voltage. Others are available for either
12 VDC or 24 VDC input.
Preprinted peel and stick nameplates for
common faults are supplied with each unit.
Most of the Selectronic Tattletale annunciators
accept either normally open (N.O.) or
normally closed (N.C.) contacts. You can mix
N.O. and N.C. contacts on the same unit.
Two mounting styles are offered;
a
recessed panel mounting flange and a free-
standing gimbal mounting. (Model STA16
is available only in flange mount).
All models except STA16 have a time delay
available to lockout the audible alarm on
startup.
These unique alarm panels have wide
ranging applications and can be grouped in
many configurations. Ask any Murphy
sales/engineer for assistance.
Basic Operation
When an alarm sensor trips, the LED
flashes and, if equipped, the Mini-Siren
sounds. At the same time an output circuit
is activated which allows you to connect an
external relay to operate a general alarm,
operate a shutdown device, etc.
Applications
Warranty
A limited warranty on materials and workmanship
is given with this FW Murphy product. A copy of
the warranty may be viewed or printed by going to
www.fwmurphy.com/support/warranty.htm
■
Provide Audible and Visual Alarm
■
Simple and Inexpensive
■
Wide Range of Applications
■
Gen-Set Models Meet NFPA-99 and
NFPA-110 Requirements
ST Series
CAUTION::
Certain dangers to human
safety and to equipment may occur
i f s o m e e q u i p m e n t i s s t o p p e d
without pre-warning. It is recommended
that monitored functions be limited to
alarm-only or to alarm before shutdown.
ST-95046B
Revised 08-06
Catalog Section 25
Selectronic
®
Tattletale
®
Remote Alarm Annunciators
ST-95046B page 1 of 6
•
Marine
•
Generator Sets
•
Oil Field
•
Agriculture
•
Construction
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
BASIC: ST5AS, ST10AS and ST5DAS Series Murphy Basic ST-Series Selectronic Tattletale annunciators are used wherever a remote alarm and annunciation is required. Typicalapplications are in marine pilot houses to alert the crew of problems developing in engine, gear, bilge, auxiliary power plants, etc...
8 First Out ST8F (flange mount) and ST8G (gimbal mount) • Provides 8-point first out cause of shutdown Tattletale. A flashing LED indicates the cause of shutdown identified by the nameplate. • Accepts N.O. and/or N.C. contacts. • Includes SPDT dry contact output rated 2 A @ 28 VDC. • Selectable sens...
Number of Alarm Points • 5 Visual• 10 Visual • 8 First Out Visual• 16 Visual Audible Alarm • 1 local; common to all inputs• 1 local; common to all inputs except battery charger malfunction and generator operating Alarm Silence: Silences audible only Test Push Button: Tests all LED's Alarm Output: Cu...