Murphy L-5937B - Manual
Murphy L-5937B – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
L-5937B page 1 of 2
For Small Engines and Pumps
■
See Oil Level and Condition
Without Shutting Down
■
Shutdown or Alarm on Low Lube Level
■
Adjustable Limit Switch for Alarm
and/or Shutdown
■
Save on Reduced Downtime
and Repair Costs
■
Simple Installation
Description
These float actuated Oil Level Swichgage instru-
ments are a combination oil level sight gage and
adjustable, low and/or high limit switch. The
limit switches are normally open during opera-
tion–yet close if the level drops or rises to where
the float contacts the limit screw. The contact
completes a circuit to ground a magneto or trip a
Murphy magnetic switch. The magnetic switch
can be used to activate alarms and/or shutdown.
Models are also available without limit switches.
Application
The level instruments described above can be
used on a variety of crankcases, pump gearcases,
or oil reservoirs–primarily on small engines and
pumps. The following list displays the model
and its typical application:
L100
†
: Small engines and pumps with
non-vented crankcase.
L100W
†
: Small engines and pumps with
vented crankcase.
L120
†
: Machined surface on crankcase such as
Witte, National-Oilwell/Garland.
L127
: Machined surface on crankcase, specifi-
cally, Fairbanks-Morse ZC Series and
Bell Engines.
L128
: Machined surface on crankcase, specifical-
ly, Arrow and Continental Emsco/Climax.
Specifications
■
Maximum Pressure Rating (all models):
30 psi (207 kPa) [2.07 bar]
■
L100 and L100W
Case:
Die cast aluminum
Float:
Brass
Rating:
2 A @ 30 VAC/DC
Vent Fitting:
1
/
4
in. (6 mm) tube x
1
/
8
NPT
Inlet Fitting:
Hex Nipple
1
/
4
NPT
Hardware (shipped loose)
L100:
• Copper Tubing:
1
/
4
x 48 in. dia.
(6 mm x 1.2 m)
• Reducer Bushing:
1
/
2
NPT x
1
/
4
NPT
• Close Nipple:
1
/
2
NPT
• Tee:
1
/
2
NPT, black pipe
• Wire:
16 AWG x 24 in. (1.5 mm
2
x 610
mm)
L100W:
• Vent Tube:
1
/
4
x 3-
3
/
8
in. (6 x 86 mm)
• Reducer Bushing:
3
/
4
NPT x
1
/
4
NPT
• Close Nipple:
3
/
4
NPT
• Tee:
3
/
4
NPT, black pipe
• Wire:
16 AWG x 24 in. (1.5 mm
2
x 610
mm)
■
L120
Case:
Cast Aluminum
Float:
Brass
Rating:
2 A @ 30 VAC/DC
Mounting Bolts:
1
/
4
-20 UNC–2A (4 req'd)
■
L127 and L128
Case:
TROGAMID
®
Nylon
Float:
Brass
Rating:
2 A @ 30 VAC/DC
Wire:
16 AWG x 48 in. (1.5 mm
2
x 1.2 m)
Mounting Bolts:
• L127:
1
/
4
-20 NC x 2 in. (4 required)
• L128:
3
/
8
-16 NC x
3
/
4
in. (2 required)
Warranty
A limited warranty on materials and workmanship
is given with this FW Murphy product. A copy of
the warranty may be viewed or printed by going to
www.fwmurphy.com/support/warranty.htm
L100
L120
L127/L128
†
Models available with high and low options. See
How to
Order
on reverse side.
**
Products covered by this bulletin comply with EMC
Council directive 89/336/EEC regarding electromagnetic
compatibility except as noted.
**
L-5937B
Revised 06-06
Catalog Section 15
Float Actuated Oil Level
Swichgage
®
instrument
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.