Morningstar Sunsaver Ss 6 - Installation Manual
Morningstar Sunsaver Ss 6 Charger – Installation Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – MORNINGSTAR CORPORATION; SunSaver Dimensions; See Section 7.0 for full technical specifications; CONTENTS
- Page 3 – SAVE THESE INSTRUCTIONS.; Safety Information; .0 Important Safety Information; IMPORTANT SAFETY INSTRUCTIONS
- Page 4 – ATTENTION:; Installation Safety Precautions; Lisez toutes les instructions et les avertissements figurant
- Page 5 – These DC connections are identified by the symbol below:; Précautions de sécurité d’installation; éviter une surchauffe excessive d’une connexion desserrée.
- Page 6 – - Power Terminal Block; GENERAL INFORMATION
- Page 7 – - Battery Status LEDs; Regulatory Information; The SunSaver controller should be installed by a qualified
- Page 8 – INSTALLATION INSTRUCTIONS; charging. Be certain there is sufficient ventilation to; even cause
- Page 9 – Installation in Hazardous Locations; CAUTION:; Select a Battery Type; The SunSaver provides a
- Page 10 – CUT
- Page 11 – Step 1: Choose Mounting Location; provide optimal airflow and could lead to overheating.; Step 2: Check for Clearance; mounted. Verify that there is sufficient room to run wires and; WARM AIR; Step 5: Secure Controller
- Page 12 – The SunSaver load output connection will provide battery; the system load(s) or load distribution panel as shown in
- Page 13 – Step 2: Battery Wiring; Unité bénéficie d’aucune protection de retrait de batterie.
- Page 14 – The nominal solar module voltage must match the; If required, the negative solar connection may be; Step 4: Confirm Wiring; Re-check the wiring in steps 1 through 3. Confirm
- Page 15 – Step 5: Install the Terminal Cover; The terminal cover prevents contact with the power; included with the cover.
- Page 16 – Step 6: Install Fuses or Close Breakers; If using circuit breakers, close the load breaker first; OPERATION; STATUS LED; when charging during the day and off at night. The Status; Color; Section
- Page 17 – BATTERY SOC LEDS; SOC; Load Off; Battery Charging Information; Bulk Charge; the battery voltage to a float charge which is sometimes
- Page 18 – Dead Battery Charging; the SunSaver, 100% of available charge current will flow to; Load Control Information; the battery is sufficiently recharged. System loads may be; Load Control Settings; Battery Status; time between a green SOC indication and load disconnect
- Page 19 – Exercise caution when connecting loads with specific; Solar Overload; Section 7.0 Technical Specifications; Load Overload; The SunSaver will attempt to reconnect the load two; Solar Short Circuit
- Page 20 – Battery Reverse Polarity; Section 7.0 Technical; Inspection and Maintenance; If applicable, check enclosure ventilation and air flow
- Page 21 – TROUBLESHOOTING; Status LED Error Indications; No LED indications; Full testing documentation is available on our website; TROUBLESHOOTIING
- Page 22 – WARRANTY AND CLAIM PROCEDURE; LIMITED WARRANTY Morningstar Solar; WARRANTY EXCLUSIONS AND LIMITATIONS; WARRANTY and CLAIM PROCEDURE; WARRANTY CLAIM PROCEDURE; dealer from whom you purchased the unit is the first step; NOTE: Please do not return units without an RMA or
- Page 23 – Electrical; Temp. Compensation Coefficient; Battery Status LEDs; Falling V Rising V; TECHNICAL SPECIFICATIONS
- Page 24 – Environmental; Ambient Temperature Range:; Mechanical; Fusing Chart; 2 VOLT NOMINAL WIRE CHART; Amps
- Page 25 – 4 Volt Nominal Wire Chart; SUNSAVER GEN 3 ADDENDUM TO; Certifications; environmental specifications); REACH
- Page 26 – Hazardous Locations for IECEx/ATEX Applications
Installation and Operation Manual
www.morningstarcorp.com
MORNINGSTAR
Wor ld’s Leading Solar
Controllers
&
Inver ters
S
UN
S
AVER
PV SYSTEM CONTROLLERS
SEALED
OR
FLOODED
SELECT
LOAD
BATTER
Y
SOLAR
Remove
Jumper
Wire for
Flooded
Battery
{
12 V
BAT
TER
Y ST
ATUS
TEMP
. SENSOR
CHAR
GING ST
ATUS
!
See Operator
’s
Manual
Nom
inal
Rat
ing
12 V
olts
dc
Max
. Inp
ut 3
0 V
Solar
20
.0 A
Bat
tery
20.
0 A
Loa
d 20
.0 A
Max
. Am
bien
t 65
º
C
indoo
r use
onl
y
Use
75
ºC C
opp
er
Con
duc
tors
On
ly
CON
FOR
MS
TO
ISA
12.
12.0
1
CER
TIFI
ED
TO
CAN
/CS
A S
TD
C22
.2 N
O.2
13-1
992
Clas
s I, D
ivis
ion
2
Group
s A,
B,C
,D
Haz
ardo
us L
oc.
Tem
p. C
ode
: T5
RoHS
MO
RN
ING
STA
R
S
S
20L
UN
AVE
R-
S O
L A
R C
O N
T R
O L
L E R
S S
- 2 0
L - 1
2 V
SunSaver Models Included in this Manual:
•
SS-6-12V / SS-6L-12V
•
SS-10-12V
•
SS-10L-12V / SS-10L-24V
•
SS-20L-12V / SS-20L-24V
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Was this manual helpful?
About this manual
- Brand
- Morningstar
- Model
- Sunsaver Ss 6
- Document type
- Installation Manual
- Category
- Charger
- Language(s)
- English
- Pages
- 26
- Format
Summary
MORNINGSTAR CORPORATION 3 2 SunSaver Dimensions Inches [Millimeters] Specification Summary Ratings SS-6/6L SS-10/10L SS-20L System Voltage 12 V 12 or 24V 12 or 24V Min. Battery Voltage 6 V 6 V 6 V Max. Solar Voltage¹ 30 V 30 or 60V 30 or 60V Max. Solar Current 6 .5 A 10 A 20 A Max. Load Current 6 A ...
MORNINGSTAR CORPORATION 5 1.0 SAFETY INFORMATION 4 1.0 SAVE THESE INSTRUCTIONS. This manual contains important safety, installation and operating instructions for the SunSaver solar controller. The following symbols are used throughout this manual to indicate potentially dangerous conditions or mark...
MORNINGSTAR CORPORATION 7 1.0 SAFETY INFORMATION 6 1.0 ! ATTENTION: Pour diminuer le risque d’incendie, ne connectez l’alimentation qu’à un circuit équipé d’une protection maximum par dérivation contre les surintensités ne dépassant pas le courant nominal du modèle de la page 2, conformément à la no...