Page 2 - WDV Series Gas Fireplace; cOntents; Installing Gas Piping to Fireplace/Burner System; thank you and congratulations on your purchase of a; Operating Instructions
2 78D0011 WDV Series Gas Fireplace cOntents Important safety Information ..................................... 3code approval ............................................................. 4product Features ......................................................... 5 High Elevations .....................
Page 3 - Cleaning and Mainte-; IMpOrtant saFety InFOrMatIOn; carBOn MOnOxIDe pOIsOnInG:; Installer; any change to this fireplace or its controls can be dangerous.; arn
78D0011 3 WDV Series Gas Fireplace 4. Never install the fireplace • in a recreational vehicle • where curtains, furniture, clothing, or other flam-mable objects are less than 42" from the front, top, or sides of the fireplace • in high traffic areas • in windy or drafty areas 5. This fireplace r...
Page 4 - National Electrical; cODe apprOVal; lIsteD VenteD Gas FIreplace heater; tured Home Construction and Safety Standard,; standard for Manufactured home Installations, ansI/ncsBcs a225.1; WARNING; HOT GLASS
4 78D0011 WDV Series Gas Fireplace IMpOrtant saFety InFOrMatIOn 14. Do not use any solid fuels (wood, coal, paper, card- board, etc.) in this fireplace. Use only the gas type indicated on rating plate. 15. This appliance, when installed, must be electrically grounded in accordance with local codes o...
Page 5 - This appliance is mobile home approved.; Model; LP; IteMs requIreD FOr InstallatIOn; Figure 2
78D0011 5 WDV Series Gas Fireplace prODuct Features and cODe apprOVal Figure 1 - WDV Fireplace Features prODuct specIFIcatIOns • This appliance has been certified for use with either natural or propane gas. See appropriate data plates. • This appliance is not for use with solid fuels. • The applianc...
Page 6 - FIreplace & FraMInG DIMensIOns
6 78D0011 WDV Series Gas Fireplace FIreplace & FraMInG DIMensIOns W arn In G Do not fill spaces around firebox with insulation or other materials. this could cause a fire. W arn In G unit framing is to be rectangular front to back. Failure to do so will cause fire and damage to property. 1/2” or...
Page 7 - pre-InstallatIOn InFOrMatIOn; Figure 3; not; Venting; cOlD clIMate InsulatIOn; Installing Horizontal Termination Configuration
78D0011 7 WDV Series Gas Fireplace pre-InstallatIOn InFOrMatIOn FIreplace lOcatIOn Plan for the installation of your appliance. This includes determining where the unit is to be installed, the vent configuration to be used, framing and finishing details, and whether any optional accessories (i.e. bl...
Page 8 - Ceiling; clearances; top View; clearances tO cOMBustIBles; Wall; side View
8 78D0011 WDV Series Gas Fireplace 72” Minimum Ceiling 12” Max. Depth 2 1 / 2 ” Max Depth 6” Min.From Opening 12” Min. From Opening 6” Min. FP2421mantel clearances clearances Mantel clearances nOte: the combustible area above the facing must not protrude more than 3/4" from the facing. If it do...
Page 9 - Use; secure FIreplace to FlOOr or FraMInG; Framing Members; te; FInIshInG MaterIal; nOte; Nailing Flange; materials which do not protrude beyond the face.
78D0011 9 WDV Series Gas Fireplace FP2430secure fireplace 6” The fireplace must be secured to the floor and/or to framing studs as shown in Figure 6. Use two (2) wood screws or masonry/ concrete screws to secure fireplace to the floor. Use four (4) screws to attach fireplace to framing. The side nai...
Page 10 - InstallatIOn precautIOns; Wear gloves and safety glasses for; VentInG InstallatIOn InFOrMatIOn; Ice
10 78D0011 WDV Series Gas Fireplace InstallatIOn precautIOns Consult local building codes before beginning the installation. The installer must make sure to select the proper vent system for installation. The approved 5 x 8 venting components are Simpson Duravent and Selkirk products listed on Page ...
Page 11 - Vent InstallatIOn; Installing A Vent System in an Outside Chase; InstallInG a Vent systeM In an OutsIDe chase
78D0011 11 WDV Series Gas Fireplace Vent InstallatIOn InstallatIOn plannInG There are two basic types of direct-vent installation: • Horizontal Termination • Vertical Termination It is important to select the proper length of vent pipe for the type of termination you choose. It is also important to ...
Page 12 - VentInG InstallatIOn; Vent Terminal; FOr hOrIZOntal terMInatIOn; Figure 9
12 78D0011 WDV Series Gas Fireplace VentInG InstallatIOn Figure 8 - Horizontal Vent Termination Location Vent Terminal Air Supply Inlet Area Where Terminals Not Permitted Inside Corner Detail FOr hOrIZOntal terMInatIOn MInIMuM DIstances A = Clearance above the grade, a veranda, porch, deck, or balco...
Page 13 - From the point of this intersection, draw a vertical line; Horizontal dimension from the finished outside
78D0011 13 WDV Series Gas Fireplace V G G=6" (152mm) F F=6" (152mm) V V G G = Combustible 24"(610mm) Noncombustible 18"(457mm) Combustible & Noncombustible H = 24" (610mm) J = 20" (508mm) V H J C = Maximum depth of 48" (1219mm) for alcove location D = Minimum width fo...
Page 14 - horizontal vent it must be reduced to 14
14 78D0011 WDV Series Gas Fireplace VentInG InstallatIOn VertIcal/hOrIZOntal terMInatIOn cOnFIGuratIOns since it is very important that the venting system main-tain its balance between the combustion air intake and the flue gas exhaust, certain limitations as to vent con-figurations apply and must b...
Page 15 - Total Angular Variation = 270°; max bends; BelOW GraDe InstallatIOns; Figure
78D0011 15 WDV Series Gas Fireplace VentInG InstallatIOn A 10’ B 7’ 10’ FP2426max vent run w/elbows Figure 14 - Maximum Vent Run with Elbows A + B = 17' Maximum 90° Elbow = 3' FP2426 Example: Elbow 1 = 90° Elbow 2 = 45° Elbow 3 = 45° Elbow 4 = 90° Total Angular Variation = 270° Figure 15 - Maximum...
Page 16 - This gas fireplace has been approved for,; Wall Screws; Do not back fill around snorkel.; Up to two 45° elbows may be used within the horizontal; Maximum horizontal length
16 78D0011 WDV Series Gas Fireplace VentInG InstallatIOn VertIcal (thrOuGh-the-rOOF) applIcatIOns This gas fireplace has been approved for, • Vertical installations up to 40' (12 m) in height. Up to a 10' (3 m) horizontal vent run can be installed within the vent system using a maximum of two 90° el...
Page 17 - Refer to Figure; Flat ceIlInG InstallatIOn
78D0011 17 WDV Series Gas Fireplace VentInG InstallatIOn InstallatIOn FOr VertIcal terMInatIOn 1. Determine the route your vertical venting will take. If ceiling joist, roof rafters or other framing will obstruct the venting system, consider an offset. Refer to Figure 20 to avoid cutting load bearin...
Page 18 - Cut a hole in the roof using the locating hole as a center; Min chimney clearance; roof pitch
18 78D0011 WDV Series Gas Fireplace VentInG InstallatIOn 3. Cut a hole in the roof using the locating hole as a center point. (Cover any exposed open vent pipes before cutting hole in roof). The 10 Z\x "x10 Z\x " (241 x 241 mm) hole must be measured on the horizontal. Actual length may be la...
Page 19 - Flex Vent InstallatIOn; the flexible venting.
78D0011 19 WDV Series Gas Fireplace Flex Vent InstallatIOn 1. Flexible UL1777 listed venting may be used in any venting application where rigid direct vent components can be used. all restrictions, clearances and allowances that pertain to the rigid piping apply to the flexible venting. Flex kits ma...
Page 20 - tions and
20 78D0011 WDV Series Gas Fireplace Flex Vent InstallatIOn Termination Cap Storm Collar Roof Support Flashing Rigid Pipe Length Flex to Pipe Adapter(FPA/8) Firestop UL1777 Flex PIpe DVF8A/8 Adapter Figure 26 - Typical Vertical Flex Vent Installation FP1975pipe connection Screws(3 Places equidistant ...
Page 21 - FIreplace InstallatIOn
78D0011 21 WDV Series Gas Fireplace FIreplace InstallatIOn checK Gas type Use proper gas type for the fireplace you are installing. If you have conflicting gas type, do not install fireplace. See dealer where you purchased the fireplace for proper fireplace for your gas type or conversion kit. Insta...
Page 22 - . Locate sediment trap/drip leg where it is within reach for clean-; natural Gas; From Gas Meter
22 78D0011 WDV Series Gas Fireplace FIreplace InstallatIOn nOte: The gas line connection may be made using 1/2" rigid tubing or an approved flex connector. Since some municipalities have additional local codes it is always best to consult your local authorities and the current edition of the Nat...
Page 23 - electrIcal WIrInG; and
78D0011 23 WDV Series Gas Fireplace sIGnature cOMManD - checK Gas pressure and electrIcal InstallatIOn 1. Check gas type. The gas supply must be the same as stated on the appliance’s rating decal. If the gas supply is different from the fireplace, stOp! Do not install the appliance. Contact your dea...
Page 24 - rn
24 78D0011 WDV Series Gas Fireplace COMMANDCENTER 4-AA BATTERYCOMPARTMENT MASTERSWTICH CONVERSIONNG/LP RF RECEIVERON/OFF BUTTON ON/HI OFF/LO LED IGNITER/SPARKER SENSING RED/THERMOPILE BLACK/THERMOPILE PILOT GAS TUBING PILOT CONTROL BOX PLUG IN CONNECTORCONTROL BOX TO COMMAND CENTER PLUG IN CONNECTOR...
Page 25 - sIGnature cOMManD - OptIOnal Fan BlOWer systeM; Before installing the blower, wire the receptacle into an; junction Box; AC Module
78D0011 25 WDV Series Gas Fireplace sIGnature cOMManD - OptIOnal Fan BlOWer systeM a/c WIrInG tO junctIOn BOx IMpOrtant: always check local building codes. this installation must comply with local regulations as well as the national electric code.WIrInG 1. Before installing the blower, wire the rece...
Page 26 - Glass reMOVal & lIGht placeMent; Remove the front floor screen frame by unfastening
26 78D0011 WDV Series Gas Fireplace Glass reMOVal & lIGht placeMent Glass FraMe reMOVal 1. Remove the front access door by lifting up and sliding the two (2) spring hinge pins inward and lifting off. 2. Rotate the three (3) cam levers in the lower access area 90° clockwise.3. Tilt glass away fro...
Page 27 - stOne & Glass placeMent; cautIOn: Do not allow stones to sit directly on burner or in flame.; Page; Glass Only placeMent; ets. The brackets are not used with glass only placement.
78D0011 27 WDV Series Gas Fireplace stOne & Glass placeMent stOne & Glass placeMent 1. For best results, place the stones first.2. Place the stones randomly against the stone stop bracket, in front of and behind the burner. cautIOn: Do not allow stones to sit directly on burner or in flame. ...
Page 28 - sIGnature cOMManD - OperatInG InstructIOns; • Do not attempt to light any appliance.; FOr yOur saFety reaD BeFOre lIGhtInG
28 78D0011 WDV Series Gas Fireplace sIGnature cOMManD - OperatInG InstructIOns a. This appliance is equipped with an ignition device which automatically lights the pilot. Refer to the instructions for match lighting. B. BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell n...
Page 29 - OperatInG InstructIOns; Read the safety information above.; tO turn OFF Gas tO applIance; switch Box; ON; OFF
78D0011 29 WDV Series Gas Fireplace sIGnature cOMManD - OperatInG InstructIOns OperatInG InstructIOns 1. stOp! Read the safety information above. 2. This appliance is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand. 3. With five (5) minu...
Page 30 - sIGnature cOMManD systeM OperatIOn InstructIOns; command center; Battery InstallatIOn; to Install Batteries:
30 78D0011 WDV Series Gas Fireplace sIGnature cOMManD systeM OperatIOn InstructIOns Features command center • Easy Access Function Operation and System Configura- tion • Operation Confirmation/Fault Diagnostic Indications (LED/ Buzzer) • ON/OFF/HI/Low Operation control Board • Electronic Ignition • ...
Page 31 - System configuration/setup is done on the Command Center.; remote transmitter learn Function (Default On); switch will activate the learn function for the transmitter.; shutting Off the standing pilot; : Pilot will resume the next time system is turned on.; Key combinations for system settings; Function
78D0011 31 WDV Series Gas Fireplace sIGnature cOMManD systeM OperatIOn InstructIOns systeM cOnFIGuratIOn/setup System configuration/setup is done on the Command Center. Intermittent/standing pilot setup (Default intermittent) 1. Holding the ON button on the Command Center while turning on the master...
Page 32 - turning on the fireplace; flashes Green once every 2 seconds, until reset.; Flame height control; pilot configuration, the pilot will be shut off.; turning the Fireplace Off; command center Operations:; The following functions are available on the Command Center.; self Diagnostics chart:
32 78D0011 WDV Series Gas Fireplace sIGnature cOMManD systeM OperatIOn InstructIOns cOMManD center FunctIOns/OperatIOn turning on the fireplace 1. Turn on the master switch and wait for a beep.2. Press the ON button on the Command Center. Pilot will light and burner will come on High setting. pilot ...
Page 33 - reMOte cOntrOl OperatIOn; General; signature remote; Manual Mode
78D0011 33 WDV Series Gas Fireplace reMOte cOntrOl OperatIOn reMOte transMItter OperatIOns General Figure 39 The RFSC Remote Control has two (2) operating modes: Manual and Thermostatic. The control system can be set to a temperature range between 45° F and 90° F. The blower speed, light, rear burne...
Page 34 - Flame height setting for thermostatic Mode
34 78D0011 WDV Series Gas Fireplace Flame height setting for thermostatic Mode Figure 43 1. Hold AUTO button for five (5) seconds and one number and flame icon will appear in LCD screen. 2. Use the ON / ▲ or OFF / ▼ button to set the desired flame height to 1 (min.) 2 (medium) or 3 (max.). 3. If the...
Page 35 - low Battery Detection; indicator will be displayed in any mode.; child-proof protection; child proof mode. Figure K; transmitter thermal shutdown; and the transmitter will turn off the fireplace.
78D0011 35 WDV Series Gas Fireplace reMOte cOntrOl OperatIOn On/OFF aux control (Optional) Figure 47 1. Press AUX button once to turn ON. AUX shows on the LCD.2. Press AUX button again to turn OFF. AUX icon disappears. °F FP2149AUX display12/08 AUX FP2149 Figure 47 - AUX Display low Battery Detectio...
Page 36 - Burner FlaMe; s installed and periodically during; cleanInG anD MaIntenance; pIlOt FlaMe; the pilot; . The pilot flame has three distinct flames, one engulfing the; Burner; Thermopile
36 78D0011 WDV Series Gas Fireplace Burner FlaMe The flames from the burner should be visually checked as soon as the heater i s installed and periodically during normal operation. In normal operation, at full rate, and after operating for about 15 to 30 minutes, the flame should be yellow. Figure 5...
Page 37 - Do not remove the glass when hot.; Final Installation; stOnes
78D0011 37 WDV Series Gas Fireplace cleanInG anD MaIntenance Vent systeM The fireplace and venting system should be inspected before initial use and at least annually by a qualified field service person. Inspect the external vent cap on a regular basis to make sure that no debris is interfering with...
Page 38 - trOuBleshOOtInG; sIGnature cOMManD systeM
38 78D0011 WDV Series Gas Fireplace trOuBleshOOtInG OPERATION Install batteries and/or plug in the AC board Flip the master switch (rocker switch) to the ON position Press the ON button on the Command Center FAULT No beep in about 8 seconds No beep or no sound from the valve indicating pilot solenoi...
Page 39 - replaceMent parts; Item Description; Glass Frame Assembly; accessories / Field Installed Options; Porcelain Panels
78D0011 39 WDV Series Gas Fireplace replaceMent parts FIreBOx cOMpOnents anD accessOrIes 1 2 3 5 7 6 780012DVW firebox parts Item Description qty. WDV500 1. Bulb 6 78D0007K 2. Bulb Socket 6 73D4521K 3. Glass Frame Assembly 1 78D0027K 4. Junction Box Assembly (not shown) 1 26D2128K 5. Panel, Access, ...
Page 41 - Item; lp to natural Gas
78D0011 41 WDV Series Gas Fireplace replaceMent parts sIGnature cOMManD systeM Item Description qty. WDV500ntsc WDV500ptsc 1. Gas Valve Assembly 1 80D0001 80D0002 2. Pilot Assembly 1 80D0006 80D0007 3. Control Box 1 80D0018 80D0018 4. Command Center 1 80D0005 80D0005 5. Tube, Tee to Venturi 2 78D009...
Page 42 - HOT; Vent cOMpOnents
42 78D0011 WDV Series Gas Fireplace HOT 1 2 3 4 5 6 9 7 8 10 730024KHLDV vent parts Vent cOMpOnents replaceMent parts
Page 46 - requirements for the commonwealth of; “Gas Vent DIrectly; ManuFacturer requIreMents; Gas equipment Venting system nOt provided
46 78D0011 WDV Series Gas Fireplace requirements for the commonwealth of Massachusetts This product must be installed by a licensed plumber or gas fitter when installed within the Commonwealth of Massachusetts. note regarding Vented products Flex line installation must not exceed 36 inches and must ...
Page 47 - lIMIteD lIFetIMe Warranty pOlIcy; lIFetIMe Warranty; number of your MHSC product.
78D0011 47 WDV Series Gas Fireplace lIMIteD lIFetIMe Warranty pOlIcy lIFetIMe Warranty The following components are warranted for life to the original owner, subject to proof of purchase: Firebox, Com-bustion Chamber, Heat Exchanger, Grate and Stainless Steel Burners. FIVe year Warranty The followin...