Monessen TPB24 - Manual

Monessen TPB24

Monessen TPB24 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
Page: / 42

Table of Contents:

  • Page 2 – CONTENTS
  • Page 3 – IMPORTANT SAFETY INFORMATION; Please leave these instructions with the appliance.; CARBON MONOXIDE POISONING:; ARNING
  • Page 4 – MASSACHUSSETTS RESIDENTS ONLY:
  • Page 5 – MAKE SURE YOU HAVE RECEIVED ALL PARTS:; CAUTION; WHAT YOU WILL NEED FOR INSTALLATION:; GETTING STARTED
  • Page 6 – PRODUCT FEATURES; SPECIFICATIONS; NATURAL GAS; natural gas systems operating at higher pressure.; IGNITION CONTROLS; OFF; - All gas to the gas logs is shut off at the valve.; IGN; THERMAL GENERATOR
  • Page 7 – GENERAL INSTALLATION INFORMATION; CODES; or; National Fire Protection Association, Inc.; Batterymarch Park; ADEQUATE COMBUSTION AND VENTILATION AIR; , defines a confined space as a space whose volume is less than 50; UNUSUALLY TIGHT CONSTRUCTION IS DEFINED AS CONSTRUCTION WHERE...; ) or less with openings gasketed or sealed
  • Page 8 – Figure 1 - Example of a Large Room with 1/2 Wall Divider
  • Page 9 – FIREPLACE AND HEARTH DIMENSIONS; Figure 2 - Hearth Minimum Dimension
  • Page 10 – PLACEMENT IN A FIREPLACE WITH A RESTRICTIVE BARRIER; IMPORTANT INFORMATION FOR THE INSTALLATION OF THIS GAS LOG SET; fully
  • Page 11 – CLEARANCES; HEIGHT REQUIREMENTS; Sidewall and ceiling clearances:; sides
  • Page 12 – be at least 1/2” thick. Sheet metal should not be installed onto; Refer to “Installing Vented Applications” found on page 18.; CLEARANCES and HEIGHT REQUIREMENTS
  • Page 13 – Figure 6 - Measuring Heat Resistant Material for Mantel
  • Page 14 – Figure 8 - Minimum Mantel Clearance with Hood - All Models
  • Page 15 – Figure 9 - Minimum Mantel Clearance with No Hood — TPB24/30; The bottom of the mantel may project from the wall a maxi-; Figure 10 is an example of an unsafe mantel installation.; OR; • Remove the mantel
  • Page 16 – FLOOR CLEARANCE; The gas log heater must be installed at least 1; Figure 11 - Minimum Clearance above Combustible Flooring
  • Page 17 – FIREPLACE PREPARATION; BEFORE FULLY INSTALLING THE UNIT:; • Turn; the gas supply to the fireplace or firebox.; Do not seal the chimney flue damper.; INSTALLING VENTED APPLICATIONS; rial and minimum mantel requirements do not apply.; this cleaning performed annually after installation.; DAMPER STOP INSTALLATION:; to prevent full closure
  • Page 18 – PLACING AND SECURING APPLIANCE; fireplace or firebox.
  • Page 19 – CONNECTING THE GAS; Figure 15 - Gas Connection
  • Page 20 – CHECKING GAS PRESSURE; The heater gas inlet connection is a; MILLI-VOLT VALVE CONTROL; Figure 16 - Pressure Test Point Location
  • Page 21 – The milli-volt valve is a self-powered combination gas control; THAT DOES NOT REQUIRE 110 VAC TO OPER-; Figure 17 - Wiring Diagram
  • Page 22 – CONNECTING REMOTE RECEIVER; Figure 18 - Installing Remote Receiver; B. Thermopile Output Reading Check; NOTICE
  • Page 23 – LOG PLACEMENT; Before you begin; After handling the logs, wash your hands gently with; Figure 20 - Installing Right Base
  • Page 24 – Left Base Log
  • Page 25 – Left Top Log
  • Page 26 – PLACING ROCK WOOL; See Figure 26; provided with log set.; Pins
  • Page 27 – RISER AND STEEL BAR GRATE INSTALLATION; OPTIONAL RISER INSTALLATION; Figure 27 - Placing Burner on Riser; STEEL BAR GRATE INSTALLATION; Figure 29 - Installing Steel Bar Grate
  • Page 28 – CAST IRON GRATE INSTALLATION; OPTIONAL CAST IRON GRATE AND ANDIRON INSTALLATION; ANDIRON INSTALLATION
  • Page 29 – PLACING THE DECORATIVE ROCK; FLAME APPEARANCE; periodically check the flames visually during operation.; CHECKING THE PILOT FLAME; It should just touch the top of the ther-; MILLI-VOLT CONTROL AND THERMOSTAT CONTROL; Figure 33 - Correct Appearance of Pilot Flame
  • Page 30 – OPERATING INSTRUCTIONS; Avoid any drafts that alter burner fl ame patterns.; Do not allow fans to blow directly into the fireplace. Do not place; CHECKING THE BURNER FLAME
  • Page 31 – Figure 36 - Location of Piezo Ignitor, Control Knobs and Switch; WHAT TO DO IF YOU SMELL GAS:; • Do not attempt to light any appliance.; FOR YOUR SAFETY READ BEFORE LIGHTING; Piezo
  • Page 32 – NOTE: If you are running the heater for the fi rst time, it may be; MILLI-VOLT CONTROL LIGHTING INSTRUCTIONS; TO TURN OFF GAS TO HEATER
  • Page 33 – CLEANING AND SERVICING; • External case should be dusted and wiped with a wet soapy cloth.; MATCH LIGHTING INSTRUCTIONS
  • Page 34 – Note: All troubleshooting items are listed in order of operation.; TROUBLESHOOTING; OBSERVED PROBLEM POSSIBLE CAUSE
  • Page 36 – BURNER ASSEMBLY
  • Page 37 – REPLACEMENT PARTS LIST; REPLACEMENT PARTS ARE AVAILABLE THROUGH YOUR RETAILER.; CIGA; ACCESSORIES SOLD SEPARATELY
  • Page 38 – CHARRED TIMBER LOGS
  • Page 39 – NOTES
  • Page 40 – MASSACHUSETTS RESIDENTS ONLY:
  • Page 41 – SPECIAL REQUIREMENTS CONTINUED; “GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS.”; NFPA 54 as adopted by the Board and
  • Page 42 – MONESSEN HEARTH SYSTEMS; LIMITED LIFETIME WARRANTY POLICY; LIFETIME WARRANTY
Loading the manual

READ AND SAVE THESE INSTRUCTIONS

UNVENTED GAS LOG

HEATER or

VENTED DECORATIVE

APPLIANCE

INSTALLATION AND OPERATING

INSTRUCTIONS

This is an unvented gas-fi red
heater. It uses air (oxygen)
from the room in which it is
installed. Provisions for adequate
combustion and ventilation air
must be provided.
Refer to page 7.

WARNINGS

If the information in this manual is not followed exactly,
a fi re or explosion may result causing property damage,
personal injury or loss of life.

– Do not store or use gasoline or other fl ammable

vapors and liquids in the vicinity of this or any other
appliance.

– WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.

• Do not touch any electrical switch; do not use any

phone in your building.

• Immediately call your gas supplier from a neighbor's

phone. Follow the gas supplier's instructions.

• If you cannot reach your gas supplier, call the fi re

department.

– Installation and service must be performed by

a qualified installer, service agency or the gas
supplier.

This appliance may be installed
in an aftermarket, permanently
located, manufactured (mobile)
home, where not prohibited by
local codes.

This appliance is only for use
with the type of gas indicated on
the rating plate. This appliance is
not convertible for use with other
gases.

MODELS: TPB18, TPB24 and TPB30

Natural Gas or Propane/LPG

Control Type: Milli-Volt

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - CONTENTS

2 70D0004 CONTENTS Important Safety Information .................................. 3 Getting Started .......................................................... 5 Product Features and Specifi cations .................... 6 Natural Gas ......................................................... 6Propane...

Page 3 - IMPORTANT SAFETY INFORMATION; Please leave these instructions with the appliance.; CARBON MONOXIDE POISONING:; ARNING

70D0004 3 IMPORTANT SAFETY INFORMATION 10. This unit complies with the latest revision of ANSI Z21.11.2 Unvented Heaters and also complies with ANSI Z21.60 Decorative Vented Appliances for Solid Fuel Burning Fireplaces. State and local codes may only allow operation of this appliance in a vented con...

Page 4 - MASSACHUSSETTS RESIDENTS ONLY:

4 70D0004 IMPORTANT SAFETY INFORMATION Continued from page 3 16. Keep room area clear and free from combustible materi- als, gasoline and other flammable vapors and liquids. 17. Unvented gas heaters are a supplemental zone heater. They are not intended to be the primary heating appli-ance. 18. Unven...

Other Monessen Models

All Monessen Other