Monessen MJ27NR - Manual

Monessen MJ27NR

Monessen MJ27NR – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
Page: / 40

Table of Contents:

  • Page 2 – CONTENTS; Placement in a Fireplace
  • Page 3 – IMPORTANT SAFETY INFORMATION; National Fuel; INSTALLER; CARBON MONOXIDE POISONING:; burns, explosion or carbon monoxide poisoning.; ARNING
  • Page 4 – utility) gas wells. This gas is commonly; Massachussetts resiDents only:
  • Page 5 – MAkE SuRE YOu hAvE RECEIvED ALL PARTS:; GETTING STARTED; G l o v e s a r e r e c o m m e n d e d w h e n; CAUTION; Do not attempt to install any part of the
  • Page 6 – NATURAL GAS; Gas Inlet Pressure:; IGNITION CONTROLS; - All gas to the gas logs is shut off at the valve.; THERMAL GENERATOR; for remote activation.
  • Page 7 – GENERAL INSTALLATION INFORMATION; CODES; or; National Fire Protection Association, Inc.; Batterymarch Park; ADEQUATE COMBUSTION AND VENTILATION AIR; , defines a confined space as a space whose; UNUSUALLY TIGHT CONSTRUCTION IS DEFINED AS CONSTRUCTION WHERE...
  • Page 9 – or BUF; the minimum hearth dimensions shown below.; DO NOT install this appliance in a factory-built fireplace that
  • Page 10 – PLACEMENT IN A FIREPLACE wITh A RESTRICTIvE BARRIER; IMPORTANT INFORMATION FOR ThE INSTALLATION OF ThIS GAS LOG SET; fully open; will extend the battery life.; Minimum Depth of Fireplace/Firebox; overheat and malfunction.; located outside the firebox.; NOTE
  • Page 11 – CLEARANCES and HEIGHT REQUIREMENTS; Sidewall and ceiling clearances:; The; The dimensions shown in; Figures 4 through 11; and defined in the fireplace manufacturer's
  • Page 12 – fireplace opening, measure the heat resistant material height,; be at least 1/2” thick. Sheet metal should not be; Hood not required
  • Page 13 – resistant material shown in; Heat Resistant; shown on; OR
  • Page 14 – A mantel may project from the wall a; mum; The bottom of the mantel may project
  • Page 15 – Figure 9 is an example of an unsafe mantel instal-; • Remove the mantel
  • Page 16 – FLOOR CLEARANCE; The gas log heater must be installed at least 1
  • Page 17 – BEFORE INSTALLING ThE APPLIANCE:; prevent full closure of the fireplace damper blade; FIREPLACE PREPARATION; BEFORE FULLY INSTALLING THE UNIT:; the gas supply to the fireplace or firebox.; Do not seal the chimney flue; INSTALLING vENTED APPLICATIONS; Since, the gas logs are operated with the damper open,; gas logs. This log set may be installed as a vented log set.; Before installing in a solid fuel burning; a positive draft, contact your dealer for assistance.
  • Page 18 – PLACING AND SECuRING APPLIANCE; inside the front edge of the fireplace or firebox.; controls during operation.; Screw
  • Page 19 – CONNECTING THE GAS; only
  • Page 20 – ChECkING GAS PRESSuRE; When tightening up the joint to the valve, hold the valve; MILLIVOLT VALVE CONTROL; turn captured screw clockwise firmly to re-seal. Do; DO NOT uSE AN OPEN FLAME.; C o n n e c t i n g d i r e c t l y t o a n
  • Page 21 – The Millivolt valve is a self-powered combination gas control; ThAT DOES NOT REquIRE 110 vAC TO OPER; Label all wires prior to disconnection when servicing controls.
  • Page 22 – CONNECTING REMOTE RECEIVER; A. COMPLETE MILLIvOLT SYSTEM ChECk; in wall or other location outside the fireplace.; NOTICE
  • Page 23 – PLACE ROCk wOOL; in front of the rear deflector shield; LOG PLACEMENT; Before you begin; • Use only rock wool
  • Page 24 – Place log #8 on right bracket next to
  • Page 26 – PLACE FLICkERING EMBERS; Figure 28 - Place Flickering Bright Embers; third right tong on the grate as shown
  • Page 27 – ANDIRON and ROCK INSTALLATION; ANDIRON INSTALLATION; Bolts; Assembly Instructions; Affix bracket to andiron using 2; PLACING ThE DECORATIvE ROCk; few hours to vent the odor.
  • Page 28 – FLAME APPEARANCE; Figure 31 - Correct Appearance of Pilot Flame
  • Page 29 – Burner will have a random pattern of yellow flames as shown in; OPERATING INSTRuCTIONS; Avoid any drafts that alter burner flame patterns.; Do not allow fans to blow directly into the; CHECKING THE BURNER FLAME
  • Page 30 – WHAT TO DO IF YOU SMELL GAS:; • If you cannot reach your gas supplier, call the fire department.; FOR YOUR SAFETY READ BEFORE LIGHTING; If you do not follow these instruction
  • Page 31 – should ignite in the Max. Height Setting.; Millivolt CONTROL LIGHTING INSTRUCTIONS; TO TURN OFF GAS TO HEATER; Turn control knob clockwise
  • Page 32 – CLEANING AND SERVICING; recommended to prevent malfunction and/or sooting.; • Do not use cleaning fluid to clean logs or any part of heater.; Refer to parts diagram for location of items; brush or pipe cleaners.; Turn off heater and allow to cool before; soap and water. Refer to manual for correct log placement.; MATCH LIGHTING INSTRUCTIONS
  • Page 33 – Note: All troubleshooting items are listed in order of operation.; TROUBLESHOOTING; OBSERvED PROBLEM POSSIBLE CAuSE; Turn appliance OFF and allow to cool before
  • Page 34 – gas supplier immediately.; Burner backfires during
  • Page 35 – Item Description; ODS Pilot Assembly; REPLACEMENT PARTS; failure to use only parts specifically
  • Page 36 – LOGS; REPLACEMENT PARTS LIST; REPLACEMENT PARTS ARE AVAILABLE THROUGH YOUR RETAILER.; F a i l u r e t o p o s i t i o n t h e p a r t s i n
  • Page 37 – MASSAChUSETTS RESIDENTS ONly:
  • Page 38 – NOTES
  • Page 39 – LIMITED LIFETIME wARRANTY POLICY; LIFETIME WARRANTY; Vent Free Ceramic Fiber Logs and Aluminized Burners.; BASIC WARRANTY; warranty repair must be accompanied by a dated proof of purchase.
  • Page 40 – MHSC
Loading the manual

860024
MJ27 cover
10/08

READ AND SAVE THESE INSTRUCTIONS

Unvented Gas Log Heater or

Vented Decorative Appliance

Installation and Operating Instructions

This is an unvented gas-fired heater.

It uses air (oxygen) from the room

in which it is installed. Provisions

for adequate combustion and

ventilation air must be provided.

Refer to page 7.

WARNINGS

If the information in this manual is not followed exactly,

a fire or explosion may result causing property damage,

personal injury or loss of life.
– Do not store or use gasoline or other flammable

vapors and liquids in the vicinity of this or any other

appliance.

– WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.

• Do not touch any electrical switch; do not use any

phone in your building.

• Immediately call your gas supplier from a neighbor's

phone. Follow the gas supplier's instructions.

• If you cannot reach your gas supplier, call the fire

department.

– Installation and service must be performed by

a qualified installer, service agency or the gas

supplier.

This appliance may be installed

in an aftermarket, permanently

located, manufactured (mobile)

home, where not prohibited by

local codes.

This appliance is only for use

with the type of gas indicated on

the rating plate. This appliance is

not convertible for use with other

gases.

MODELS: MJ27NR, MJ27PR

Natural Gas or Liquid Propane

Control Type: Millivolt Hi/Low

86D0024 10/08 Rev. 1

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - CONTENTS; Placement in a Fireplace

2 86D0024 CONTENTS Important Safety Information .................................. 3 Getting Started .......................................................... 5 Product Features and Specifications .................... 6 Natural Gas ......................................................... 6 Propane...

Page 3 - IMPORTANT SAFETY INFORMATION; National Fuel; INSTALLER; CARBON MONOXIDE POISONING:; burns, explosion or carbon monoxide poisoning.; ARNING

86D0024 3 IMPORTANT SAFETY INFORMATION 9. The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.l/NFPA54. 10. This unit complies with the latest revision of ANSI Z21.11.2-2007 Unvented Heaters and also complies with ANSI Z21.60 D...

Page 4 - utility) gas wells. This gas is commonly; Massachussetts resiDents only:

4 86D0024 IMPORTANT SAFETY INFORMATION continued from page 3 15. This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Pro - visions for adequate combustion and ventilation air must be provided. See page 8. 16. Keep room area clear and free from combustib...