Monessen CWC500 - Manual
Monessen CWC500 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – CWC Series Woodburning Fireplace; Safety Information; Description; beginning; Any such action may possibly cause a fire hazard.; installing the fireplace.; Listed; Standard for Factory built Fireplaces; Table of Contents; Drafts; before; framing the fireplace. The gas line must be
- Page 3 – CWC500 Series Woodburning Fireplace — Circulating Model; CWC400 Series Woodburning Fireplace — Circulating Model
- Page 4 – Chase Installation; Front Width
- Page 5 – RISE; Chimney Requirements - Offset Installations; 0° elbow Offsets; Illustration Key; OFFSET; total
- Page 6 – Planning Information; Mounting the Fireplace; must; Planning the Chimney Run; Never; The Ten Foot Rule
- Page 7 – Chimney Supports; must not; highly recommended; Installation
- Page 8 – Framing; Framing should be positioned to accommo-; Install electrical Connection; To prevent electrical shock, the house; Install Variable Speed Control; Installation Instructions
- Page 9 – REPORT TO YOUR DEALER ANY PARTS; To use the TWABR adapter on the CWC400,; Straight-Up Chimney Installation; 0° Offset Elbow; Ceiling Chimney Hole/
- Page 10 – Framing the Ceiling Hole; Safety strips are not required over noncombus-; Size of Chimney; Angle of Chimney at Ceiling; Securing The Fireplace
- Page 11 – Installing Outside Air Kit; MUST; elbow Strap; Installing the Chimney System; Make sure the; Installing the Firestop Spacer; is; is not
- Page 12 – Attic Installation; DO NOT; put any sealant around the area where the; it may cause a fire hazard.; If the attic insulation shield is used, the; use an approved
- Page 13 – Hole dimensions given in the chim-; horizontal; Ten Foot Rule; Do not; If a combustible material is; Front View; Air Space Clearances
- Page 14 – No side wall protection is required for fireplaces; Side Wall Protection; Top View
- Page 15 – Hearth Installation; or; Minimum Wall Clearances
- Page 16 – COMMON MATERIALS AND FACTORS; To determine the thickness required for any; new; example for Common brick; Side View
- Page 17 – If installing an unvented gas log set, refer to statement below:; Installing Line for gas Logs; When installing an ANSI Z21.11.2 ventless; Fireplace Top View
- Page 19 – Accessories; Model Number
- Page 20 – Chimney Components
- Page 23 – LIMITeD WARRANTY; Factory-build Fireplace and Components; From the eleventh through the twenty-fifth year following the; What is Not Covered; ferentials produced by wind.; Limitations and exclusions; in connection with this fireplace and accessory.; MHSC
For Models:
CWC400
CWC500
For use in U.S./Canada
Underwriter's Laboratories
Report No. MH7603
DO NOT DISCARD THIS MANUAL: Retain for future use.
87D1504 12/09 Rev. 4
FP583A
WMC
12/18/98
CWC Series
Woodburning Fireplaces
Homeowner's Installation
and Operating Manual
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 CWC Series Woodburning Fireplace 87D1504 Safety Information PLeASe ReAD THIS MANUAL beFORe INSTALLINg AND USINg FIRePLACe.IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void th...
3 CWC Series Woodburning Fireplace 87D1504 50" (1270mm) 42" (1067mm) 35 Z\v " (895mm) 46" (1168mm) B\, " (16mm) B\, " (16mm) Z\x " (13mm) Z\x " 19 C\v " (502mm) 1 C\v " (45mm) 38" (965mm) 21" (533mm) 7 C\v " (197mm) 7 Z\x " (191mm) Recessed Nai...
4 CWC Series Woodburning Fireplace 87D1504 Chase Installation Insulation methods shown are optional for cold climate, not a requirement for unit operation. FPC554 Fig. 3 Fireplace and chase parts identification. Termination Cap Storm Collar Pan Flashing Draftstop Top Shield Surround Outlet Grille Da...