Page 2 - CDVSC7 & CDV7 Series Gas Fireplace; ConTenTS; pre-Installation Information; General Venting
CDVSC7 & CDV7 Series Gas Fireplace 69D3011 ConTenTS Important Safety Information .................................... 3Code approval ............................................................ 4product Specifications............................................... 5 High Elevations ................
Page 3 - Cleaning and Maintenance; IMpoRTanT SaFeTy InFoRMaTIon; CaRBon MonoxIDe poISonInG:; Continued on page 4; InSTalleR; any change to this fireplace or its controls can be dangerous.; In
CDVSC7 & CDV7 Series Gas Fireplace 69D3011 3 4. Never install the fireplace • in a recreational vehicle • where curtains, furniture, clothing, or other flam-mable objects are less than 4" from the front, top, or sides of the fireplace • in high traffic areas • in windy or drafty areas 5. Thi...
Page 4 - National Electrical; CoDe appRoVal; lISTeD VenTeD GaS FIReplaCe heaTeR; pleaSe ReaD The FollowInG CaReFully; WARNING
CDVSC7 & CDV7 Series Gas Fireplace 4 69D3011 IMpoRTanT SaFeTy InFoRMaTIon 1. Do not use this fireplace to cook food or burn paper or other objects. 13. Never place anything on top of fireplace.14. Do not use any solid fuels (wood, coal, paper, card- board, etc.) in this fireplace. Use only the g...
Page 5 - pRoDuCT FeaTuReS
CDVSC7 & CDV7 Series Gas Fireplace 69D3011 5 pRoDuCT FeaTuReS pRoDuCT SpeCIFICaTIonS • This appliance has been certified for use with either natural or propane gas. See appropriate data plates. • This appliance is not for use with solid fuels. • The appliance is approved for bedroom or bedsittin...
Page 6 - GaS pReSSuReS; Natural; pRoDuCT FeaTuReS & GaS SpeCIFICaTIonS
CDVSC7 & CDV7 Series Gas Fireplace 6 69D3011 GaS pReSSuReS hIGh eleVaTIonS Input ratings are shown in BTU per hour and are certified without deration for elevations up to 4,500 feet (1,370 m) above sea level.For elevations above 4,500 feet (1,370 m) in USA, installations must be in accordance wi...
Page 7 - FIReplaCe DIMenSIonS & FRaMInG; Framing Dimensions
CDVSC7 & CDV7 Series Gas Fireplace 69D3011 7 Figure 2 - CDVR Series Fireplace Dimensions FIReplaCe DIMenSIonS & FRaMInG G F H A J C Q D E 1 56M ” 15/16” P - Minimum Rough Opening Width Minimum RoughOpening Depth 1/2” 5/8” 5/8” 1/2” Minimum RoughOpening Height CL 5/8” 1/2” 5/8” 1/2” I K L M O...
Page 9 - Figure 2; Figure 3; Do not bring headers
CDVSC7 & CDV7 Series Gas Fireplace 69D3011 9 pRe-InSTallaTIon InFoRMaTIon BeFoRe you STaRT Read this homeowner manual thoroughly and follow all instructions carefully. Inspect all contents for shipping damage and immediately inform your dealer if any damage is found. Do not install any unit with...
Page 10 - FIReplaCe loCaTIon; Figure 4; not; Vent pipe routing. See; pRe-InSTallaTIon InFoRMaTIon
CDVSC7 & CDV7 Series Gas Fireplace 10 69D3011 FIReplaCe loCaTIon Plan for the installation of your appliance. This includes determining where the unit is to be installed, the vent configuration to be used, framing and finishing details, and whether any optional accessories (i.e. blower, wall swi...
Page 11 - CleaRanCeS; ManTel CleaRanCeS; The combustible area above the facing must; Front View
CDVSC7 & CDV7 Series Gas Fireplace 69D3011 11 CleaRanCeS CleaRanCeS To CoMBuSTIBleS w a R n In G Follow these instructions carefully to ensure safe installation. Failure to follow i n s t r u c t i o n s e x a c t l y c a n c r e a t e a f i r e hazard.The appliance cannot be installed on a carp...
Page 12 - Figure 7; SeCuRe FIReplaCe To FlooR oR FRaMInG; finishing to avoid costly reconstruction.
CDVSC7 & CDV7 Series Gas Fireplace 1 69D3011 The fireplace must be secured to the floor and/or to framing studs as shown in Figure 7 . Use two () wood screws or masonry/ concrete screws to secure fireplace to the floor. Use four (4) screws to attach fireplace to framing. The side nailing flanges...
Page 13 - InSTallaTIon pReCauTIonS; GeneRal VenTInG; location of Vent Termination; feet or higher (top vent units only), the clearances for the
CDVSC7 & CDV7 Series Gas Fireplace 69D3011 13 InSTallaTIon pReCauTIonS Consult local building codes before beginning the installation. The installer must make sure to select the proper vent system for installation. Before installing vent kit, the installer must read this fireplace manual and ven...
Page 14 - VenTInG InSTallaTIon InFoRMaTIon; GeneRal VenTInG InFoRMaTIon - TeRMInaTIon loCaTIon; Canadian Installations
CDVSC7 & CDV7 Series Gas Fireplace 14 69D3011 VenTInG InSTallaTIon InFoRMaTIon V V V V V V V X X X D E B B B C B M B A J K F L VENT TERMINATION AIR SUPPLY INLET AREA WHERE TERMINAL IS NOT PERMITTED H I Fixed Closed Operable Operable Fixed Closed V B CFM145a DV Te...
Page 15 - Termination Clearances; GeneRal InFoRMaTIon aSSeMBlInG VenT pIpeS; uSa Installations; Flex Vent pipes
CDVSC7 & CDV7 Series Gas Fireplace 69D3011 15 VenTInG InSTallaTIon InFoRMaTIon Outside Corner Inside Corner Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors. G = Combustible 6" (152 mm) Noncombustible 2" (51 mm) F = Combustible 6...
Page 16 - TwIST loCK pIpeS
CDVSC7 & CDV7 Series Gas Fireplace 16 69D3011 TwIST loCK pIpeS When using twist lock pipe it is not necessary to use seal-ant on the joints. The only areas of the venting system that need to be sealed with high temperature silicone sealant are the sliding joints of any telescopic vent section us...
Page 17 - how To uSe The VenT GRaph; the point intersecting with the slanted graph line.; Refer to
CDVSC7 & CDV7 Series Gas Fireplace 69D3011 17 how To uSe The VenT GRaph The Vent Graph should be read in conjunction with the following vent installation instructions to determine the re-lationship between the vertical and horizontal dimensions of the vent system.1. Determine the height of the c...
Page 18 - VenTInG InSTallaTIon; until; feet or higher when top; CDVR Series
CDVSC7 & CDV7 Series Gas Fireplace 18 69D3011 3" 1" 1" 1" FP2288TV rear vent VenTInG InSTallaTIon Figure 14 - Combustible Clearances for Vent Pipe A Minimum of 3" Clearance to the Top Is Required Along Horizontal Length until Flue Pipe Penetrates Outside Wall. A M i n i m u m...
Page 19 - ReaR wall VenT applICaTIon; noncombustible walls:; Vent opening for Combustible walls; opening for noncombustible wall
CDVSC7 & CDV7 Series Gas Fireplace 69D3011 19 ReaR wall VenT applICaTIon When installed as a rear vent unit this appliance may be vented directly to a termination located on the rear wall behind the appliance. • Only MHSC venting components are approved to be used in these applications (Refer to...
Page 20 - Follow Steps 1 and on Page 19.; Top VenT SIDewall applICaTIon; For all top vent installations where a 90° elbow; system
CDVSC7 & CDV7 Series Gas Fireplace 0 69D3011 VenTInG InSTallaTIon FP2294Side View Vent Termination1/25/00 djt Finish Wall Vent Termination FP94 Figure 17 - Side View of Final Unit Location ReaR wall VenT InSTallaTIonS - Flex VenT pIpe Follow Steps 1 and on Page 19. Step 3 Install the 4” (10 mm) ...
Page 22 - When using flex vent, the opening will have to be; noncombustible walls:; Hole opening must be 7; Secure firestop to the inside frame, center in the 9; always install horizontal venting on a level
CDVSC7 & CDV7 Series Gas Fireplace 69D3011 VenTInG InSTallaTIon VeRTICal SIDewall InSTallaTIon -TwIST loCK pIpe Step 1 Locate vent opening on the wall. It may be necessary to first position the fireplace and measure to obtain hole lo-cation. Depending on whether the wall is combustible or noncom...
Page 23 - ” (165 mm) from the top of the unit
CDVSC7 & CDV7 Series Gas Fireplace 69D3011 3 VenTInG InSTallaTIon Step 6 Use appropriate length of pipe sections - telescopic or fixed - and install. The sections which go through the wall are packaged with the starter kit, and can be cut to suit if necessary. Sealing vent pipe and firestop gaps...
Page 24 - Do not back fill around snorkel.
CDVSC7 & CDV7 Series Gas Fireplace 4 69D3011 VenTInG InSTallaTIon Below GRaDe InSTallaTIon When it is not possible to meet the required vent terminal clearances of 1” (305 mm) above grade level, a snor-kel kit is recommended. It allows installation depth down to 7” (178 mm) below grade level. Th...
Page 25 - upper Floor
CDVSC7 & CDV7 Series Gas Fireplace 69D3011 5 • For the minimum height of the vent above the highest point of penetration through the roof refer to Figure 38, Page 6. Max. Height 40’ (1. m) Min. Height 8’ (.4 m) Max. 10’ (3 m) Support Straps Every 3’ (.9 m) Max. Height 40’ (1. m) Min. Height 8’ (...
Page 26 - Apply high temperature sealant to 4” and 7” collars
CDVSC7 & CDV7 Series Gas Fireplace 6 69D3011 VenTInG InSTallaTIon FP1184Typical roof/ceilingsupport apps. Typical Roof Support application Typical Ceiling Support application FP1184 Figure 37 - Venting Supports TWL101aTwist Lock Pipe2/8/99 djt 3 #5 Sheet Metal Screws per Joint Sealant Storm Coll...
Page 27 - FIReplaCe InSTallaTIon; InSTallaTIon ITeMS neeDeD
CDVSC7 & CDV7 Series Gas Fireplace 69D3011 7 FIReplaCe InSTallaTIon CheCK GaS Type Use proper gas type for the fireplace you are installing. If you have conflicting gas type, do not install fireplace. See dealer where you purchased the fireplace for proper fireplace for your gas type or con-vers...
Page 28 - Install main gas valve (equipment shutoff valve); natural Gas; From Gas Meter
CDVSC7 & CDV7 Series Gas Fireplace 8 69D3011 FIReplaCe InSTallaTIon A listed manual shutoff valve must be installed upstream of the appliance. Union tee and plugged 1/8" NPT pressure tapping point should be installed upstream of the appliance. Figure 41 IMpoRTanT: Install main gas valve (equ...
Page 29 - CheCK GaS pReSSuRe & eleCTRICal InSTallaTIon; eleCTRICal wIRInG
CDVSC7 & CDV7 Series Gas Fireplace 69D3011 9 CheCK GaS pReSSuRe & eleCTRICal InSTallaTIon 1. Check gas type. The gas supply must be the same as stated on the appliance’s rating decal. If the gas supply is different from the fireplace, STop! Do not install the appliance. Contact your dealer i...
Page 30 - ReMoTe wall MounTeD SwITCh; Hearth Mount
CDVSC7 & CDV7 Series Gas Fireplace 30 69D3011 ON OFF OPTIONAL REMOTE WALL SWITCH ON OFF OPTIONAL REMOTE CONTROL RECEIVER PILOT HI LO ON OFF THTP TH/TP ON OFF RS FP1980Dv wiring diagram ReMoTe wall MounTeD SwITCh A remote wall switch and up to fifteen (15) feet of 18 Ga. wire may be used with thi...
Page 31 - eleCTRICal InSTallaTIon
CDVSC7 & CDV7 Series Gas Fireplace 69D3011 31 eleCTRICal InSTallaTIon eleCTRonIC pIloT IGnITIon wIRInG Figure 45 - Remote Wall Switch Wiring Diagram #1 #2 #3 #4 #5 #6 7# Electronic Valve GRAY #7 RED #2 RED #2 BLACK #4 GREEN #6 BLUE #1 BLUE YELLOW YELLOW WHITE #3 MAGENTA #5 15’ Wall Switch Wire ...
Page 32 - MIllIVolT opeRaTInG InSTRuCTIonS; whaT To Do IF you SMell GaS:; FoR youR SaFeTy ReaD BeFoRe lIGhTInG; InITIal lIGhTInG
CDVSC7 & CDV7 Series Gas Fireplace 3 69D3011 MIllIVolT opeRaTInG InSTRuCTIonS a. This appliance is equipped with a pilot which must be lit with built-in piezo ignitor while following these instructions exactly. B. BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell nex...
Page 33 - Continued on next page; appRoVeD leaK TeSTInG MeThoD; lIGhTInG pIloT
CDVSC7 & CDV7 Series Gas Fireplace 69D3011 33 MIllIVolT opeRaTInG InSTRuCTIonS PILOT O FF P IL O T ON FP1935control knob pilot Continued on next page appRoVeD leaK TeSTInG MeThoD You may check for gas leaks with the following methods only: • Soap and water solution • An appro...
Page 34 - control knob on; OFF; lIGhTInG BuRneR; MaIn BuRneR SwITCh; Depress and turn the knob counterclockwise; pIloT poSITIon; Depress and turn knob clockwise; To TuRn oFF GaS
CDVSC7 & CDV7 Series Gas Fireplace 34 69D3011 MIllIVolT opeRaTInG InSTRuCTIonS PILOT OF F PILOT O N OF F PILO T ON PILOT FP1937 control knob on Figure 49 - On Position PILOT O FF P IL O T ON FP1935control knob pilot Figure 48 - On/Off/RS Switch OFF ON RS lIGhTInG BuRneR MaIn ...
Page 35 - eleCTRonIC IGnITIon opeRaTInG InSTRuCTIonS; lIGhTInG eleCTRonIC IGnITIon; To Turn Off Gas
CDVSC7 & CDV7 Series Gas Fireplace 69D3011 35 eleCTRonIC IGnITIon opeRaTInG InSTRuCTIonS a. This appliance is equipped with an ignition device (Piezo) which automatically lights the pilot. Do NOT try to light the burner by hand. B. BEFORE OPERATING smell all around the appliance area for gas. Be...
Page 36 - General
CDVSC7 & CDV7 Series Gas Fireplace 36 69D3011 SIGnaTuRe CoMManD - CheCK GaS pReSSuRe and eleCTRICal InSTallaTIon 1. Check gas type. The gas supply must be the same as stated on the appliance’s rating decal. If the gas supply is different from the fireplace, STop! Do not install the appliance. Co...
Page 37 - junCTIon Box wIRInG; . Remove the external junction box cover by removing the; The connection is labeled “Wall Switch”. Unplug
CDVSC7 & CDV7 Series Gas Fireplace 69D3011 37 junCTIon Box wIRInG 1. This should be done before framing the fireplace. Wire the receptacle into an electrical circuit. Wire with minimum 60° C wire in accordance with prevailing codes. . Remove the external junction box cover by removing the screw ...
Page 38 - Wall switch wires must be con-
CDVSC7 & CDV7 Series Gas Fireplace 38 69D3011 To Junction Boxin Fireplace Optional AC Module { White Black Optional Light White Black { Optional Blower White Black { Optional Aux. Green Plug in Connector Connector Pin To Control Board Input 300 Watt Max. Each Optional A/C Module Replaces 6V Ada...
Page 39 - Control Box; opTIonal Fan BloweR SySTeMS
CDVSC7 & CDV7 Series Gas Fireplace 69D3011 39 To Junction BoxIn Fireplace WHITE BLACK WHITE BLACK BLACK WHITE GREEN ConnectorPin To Contro l Box { { Optional Light Optional AUX Blower (300w Max) FP2103AC fan wiring Figure 57 -Blower Wiring Diagram FP103 Control Box optional aC Module opTIonal Fa...
Page 40 - This must be done before framing the fireplace. When
CDVSC7 & CDV7 Series Gas Fireplace 40 69D3011 opTIonal Fan BloweR SySTeMS BloT auToMaTIC TheRMoSTaT BloweR Figure 58 - BLOT Blower Wiring Diagram BLACK BLACK WHITE GREEN BLACK BLACK WHITE Receptacle Junction Box 120VAC Speed Control FP2675BLOT blower wiring FP675 Before installing the blower,...
Page 41 - opeRaTInG InSTRuCTIonS - SIGnaTuRe CoMManD; • Do not attempt to light any appliance.; continued on next page
CDVSC7 & CDV7 Series Gas Fireplace 69D3011 41 opeRaTInG InSTRuCTIonS - SIGnaTuRe CoMManD a. This appliance is equipped with an ignition device which automatically lights the pilot. Refer to the instructions. B. BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next t...
Page 42 - opeRaTInG InSTRuCTIonS; Read the safety information above.; To TuRn oFF GaS To applIanCe; Command Center; oFF
CDVSC7 & CDV7 Series Gas Fireplace 4 69D3011 opeRaTInG InSTRuCTIonS opeRaTInG InSTRuCTIonS - SIGnaTuRe CoMManD 1. STop! Read the safety information above. . This appliance is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand. 3. Wait f...
Page 43 - FeaTuReS; Control Board; BaTTeRy InSTallaTIon
CDVSC7 & CDV7 Series Gas Fireplace 69D3011 43 FeaTuReS Command Center • Easy Access Function Operation and System Configuration • Operation Confirmation/Fault Diagnostic Indications (LED/ Buzzer) • ON/OFF/HI/Med/Low Operation • Optional Wall Mounting Control Board • Electronic Ignition • Pilot L...
Page 44 - SySTeM ConFIGuRaTIon/SeTup; Remote Transmitter learn Function (Default oFF); Key Combinations for System Settings; Function
CDVSC7 & CDV7 Series Gas Fireplace 44 69D3011 SySTeM ConFIGuRaTIon/SeTup All System configuration/setup is done on the Command Center. noTe: When using On/Off wall switch, the switch must be in the ON position to perform all configuration set ups at the command center. Intermittent/Standing pilo...
Page 45 - SIGnaTuRe CoMManD SySTeM opeRaTIon InSTRuCTIonS; flashes Green once every seconds, until reset.; Command Center operations:; The following functions are available on the Command Center.; Self Diagnostics Chart:
CDVSC7 & CDV7 Series Gas Fireplace 69D3011 45 SIGnaTuRe CoMManD SySTeM opeRaTIon InSTRuCTIonS FunCTIonS/opeRaTIon Turning on the fireplace 1. Turn on the master switch and wait for a beep.. Press the ON button on the Command Center or turn on wall switch. Pilot will light and burner will come on...
Page 46 - GlaSS ReMoVal & RoCK wool plaCeMenT; Tilt glass frame out and lift glass frame up until it clears; RoCK wool plaCeMenT; For best results in flame appearance and opera-; au
CDVSC7 & CDV7 Series Gas Fireplace 46 69D3011 GlaSS ReMoVal & RoCK wool plaCeMenT GlaSS FRaMe ReMoVal 1. Remove upper and lower louvers. . Release the clamps on the bottom of the fireplace. Figure 61 3. Tilt glass frame out and lift glass frame up until it clears the hook on top of the frame...
Page 47 - loG plaCeMenT
CDVSC7 & CDV7 Series Gas Fireplace 69D3011 47 LG637CDV logs loG plaCeMenT loG plaCeMenT Figure 63 1. Place rear log (#1) on grate assembly. Log should rest firmly on the two log mounting pins shown. . Place top right log (#) on the rear log. Rest the right back side of the log in the flat area o...
Page 48 - pIloT FlaMe; The pilot flame must always be pres-; The; BuRneR; The type of installation, vent system; CleanInG anD MaInTenanCe
CDVSC7 & CDV7 Series Gas Fireplace 48 69D3011 BuRneR, pIloT anD ConTRol CoMpaRT-MenT Keep the control compartment, logs, and burner areas surrounding the logs clean by vacuuming or brushing at least twice a year. Make sure the burner porting, pilot air opening and burner air opening are free of ...
Page 49 - Do not remove the glass when hot.; loGS; Do not use fluids to clean ceramic fiber logs.; RoCK wool; Final Installation
CDVSC7 & CDV7 Series Gas Fireplace 69D3011 49 CleanInG anD MaInTenanCe VenT SySTeM The fireplace and venting system should be inspected before initial use and at least annually by a quali-fied field service person. Inspect the external vent cap on a regular basis to make sure that no debris is i...
Page 50 - STanDInG pIloT IGnITIon; SyMpToM
CDVSC7 & CDV7 Series Gas Fireplace 50 69D3011 STanDInG pIloT IGnITIon TRouBleShooTInG SyMpToM poSSIBle CauSe aCTIon 1. Spark ignitor will not light pilot after repeated triggering of piezo. . Pilot will not stay lit after carefully follow-ing lighting instruc-tions. 3. Pilot burning, valve knob ...
Page 51 - TRouBleShooTInG
CDVSC7 & CDV7 Series Gas Fireplace 69D3011 51 STanDInG pIloT IGnITIon SyMpToM poSSIBle CauSe aCTIon 4. Frequent pilot outage problem. 5. The pilot and main burner extinguish while in operation 6. Glass Soots 7. Flame burns blue and lifts off burner (ghosting) A. Pilot flame may be too high or to...
Page 52 - eleCTRonIC IGnITIon; Correct if necessary.
CDVSC7 & CDV7 Series Gas Fireplace 5 69D3011 eleCTRonIC IGnITIon TRouBleShooTInG STaRT 1. Turn gas supply off.. Turn ON/OFF switch to “ON” Power to module (4V Normal) yeS Is there a spark across ignitor sensor gap? yeS Turn on gas. Does pilot burner light? yeS Does spark stop when pilot is lit? ...
Page 53 - SIGnaTuRe CoMManD SySTeM
CDVSC7 & CDV7 Series Gas Fireplace 69D3011 53 TRouBleShooTInG OPERATION Install batteries and/or plug in the AC board Flip the master switch (rocker switch) to the ON position Press the ON button on the Command Center FAULT No beep in about 8 seconds No beep or no sound from the valve indicating...
Page 54 - ReplaCeMenT paRTS
CDVSC7 & CDV7 Series Gas Fireplace 54 69D3011 ReplaCeMenT paRTS FIReBox CoMponenTS 1 4 2 3 6 6 5 (CDVR Series) 5 (CDVT Series) 6 6 12 9 7,10,11,13
Page 55 - FIReBox CoMponenTS; Item Description
CDVSC7 & CDV7 Series Gas Fireplace 69D3011 55 FIReBox CoMponenTS ReplaCeMenT paRTS Item Description qty. CDVR33 CDVT33 CDVR36 CDVT36 CDVR42 CDVT42 CDVR47 CDVT47 Standard Features 1. Junction Box Assy 1 6D18K 6D18K 6D18K 6D18K 6D18K 6D18K 6D18K 6D18K . Black Louver 6 54D046 54D046 6D0695 6D0695 6...
Page 57 - STanDInG pIloT – MIllIVolT ConTRol; part number; Thermostatic Remote Control; lp to natural Gas
CDVSC7 & CDV7 Series Gas Fireplace 69D3011 57 STanDInG pIloT – MIllIVolT ConTRol ReplaCeMenT paRTS Item Description qty. CDV33nV7 CDV33pV7 CDV36nV7 CDV36pV7 CDV42nV7 CDV42pV7 CDV47nV7 CDV47pV7 1. Gas Valve Assy. 1 37D0117 37D0118 37D0117 37D0118 37D0117 37D0118 37D0117 37D0118 . Pilot Assembly 1...
Page 62 - VenTInG CoMponenTS; Description; Venting Components; VeRTICal VenTInG
CDVSC7 & CDV7 Series Gas Fireplace 6 69D3011 VenTInG CoMponenTS Description Model number Vertical Vent Termination Kits Vertical Vent Termination w/ Storm Collar 7TDVSKV (flashing NOT included) Vertical Vent Termination w/ Storm Collar - 8 pack 7TDVSKV/8 (flashing NOT included) Vertical Vent Ter...
Page 63 - hoRIZonTal VenTInG
CDVSC7 & CDV7 Series Gas Fireplace 69D3011 63 VenTInG CoMponenTS Description Model number Horizontal Vent Termination Kits Rear Vent Hot Touch Termination Kit w/ 10" to 16" 7TBRHTK Adjustable Termination Pipe, Firestop, and Hot Touch Termination w/ Siding Shield Up and Out Side Wall Term...
Page 66 - noTe ReGaRDInG VenTeD pRoDuCTS
CDVSC7 & CDV7 Series Gas Fireplace 66 69D3011 noTe ReGaRDInG VenTeD pRoDuCTS This product must be installed by a licensed plumber or gas fitter when installed within the Commonwealth of Massachusetts.Any residence with a direct vent product must have a CO detector installed in the residence.Inst...
Page 67 - lIMITeD lIFeTIMe waRRanTy polICy; lIFeTIMe waRRanTy; model/serial number of your MHSC product.
CDVSC7 & CDV7 Series Gas Fireplace 69D3011 67 lIMITeD lIFeTIMe waRRanTy polICy lIFeTIMe waRRanTy The following components are warranted for life to the original owner, subject to proof of purchase: Firebox, Combustion Chamber, Heat Exchanger, Grate and Stainless Steel Burners. FIVe yeaR waRRanTy...
Page 68 - efficiency Ratings; Model
MhSC 149 Cleveland Drive • Paris, Kentucky 40361 www.mhsc.com Based on CSA P.4.1-09 Based on CSA P.4.1-09 Recherchez dans la brochure les caractéristique de rendement énergétique de foyer au gaz Énerguide Selon CSA P.4.1-09 efficiency Ratings Model enerGuide Ratings Fireplace efficiency (%) CDVR33NV...