- Page 3 – National Fuel Gas; INSTALLER; Please leave these instructions with the owner.; OWNER; Please retain these instructions for future reference.; IMPORTANT; IMPORTANT SAFETY INFORMATION; CARBON MONOXIDE POISONING:; burns, explosion or carbon monoxide poisoning.; ARNING
- Page 5 – PRODUCT FEATURES; Figure 1 - Cast Iron Stove
- Page 6 – GETTING STARTED; MAKE SURE YOU HAVE RECEIVED ALL PARTS:; CAUTION
- Page 7 – PRODUCT SPECIFICATIONS; NATURAL GAS; systems operating at higher pressure.; IGNITION CONTROLS; All gas to the burner is shut off at the valve.; THERMAL GENERATOR
- Page 8 – American National Standards Institute, Inc.; or; National Fire Protection Association, Inc.; Batterymarch Park; GENERAL INSTALLATION INFORMATION; defines a confined space as a space whose volume is less than 50; UNUSUALLY TIGHT CONSTRUCTION IS DEFINED AS CONSTRUCTION WHERE...; ) or less with openings gasketed or sealed
- Page 9 – Figure 2 - Example of a Large Room with 1/2 Wall Divider
- Page 10 – CLEARANCES / HEIGHT REQUIRMENTS; Figure 3 - Minimum Clearance to Walls and Ceiling; Figure 3
- Page 11 – CONNECTING THE GAS; Figure 4 - Gas Connection
- Page 12 – CHECKING GAS PRESSURE; DO NOT USE AN OPEN FLAME.; MILLIVOLT CONTROL; Figure 5 - Pressure Test Point Location; CONNECTING REMOTE RECEIVER; Figure 6 - Installing Remote Receiver
- Page 13 – The milli-volt valve is a self-powered combination gas control; THAT DOES NOT REQUIRE 110 VAC TO OPERATE.; Figure 7 - Wiring Diagram; CONNECTING OPTIONAL WALL SWITCH OR THERMOSTAT; A. COMPLETE MILLIVOLT SYSTEM CHECK
- Page 14 – Figure 9 - Installing T-Stat Sensor and Control Knob
- Page 15 – Remove adhesive backing from plastic clip. Press; OPERATION OF THERMOSTAT SENSOR
- Page 16 – LOG PLACEMENT; INSTALLING LOGS ON GRATE; position and stability.; Before you begin; After handling the logs, wash your hands gently with
- Page 17 – FLAME APPEARANCE; See Figure 13; CHECKING BURNER FLAME; Avoid any drafts that alter burner flame patterns.; This is a normal and temporary
- Page 18 – WHAT TO DO IF YOU SMELL GAS:; OPERATING INSTRUCTIONS; FOR YOUR SAFETY READ BEFORE LIGHTING
- Page 19 – NOTE: To use the optional thermostat function (if; TO TURN OFF GAS TO HEATER; Figure 18 - Control Cover Plate for Milli-Volt; MILLI-VOLT CONTROL LIGHTING INSTRUCTIONS
- Page 20 – the pilot and ignite the pilot.; CLEANING AND SERVICING; air intake holes clean will result in sooting and poor combustion.; MATCH LIGHTING INSTRUCTIONS
- Page 21 – REPLACEMENT PARTS ARE AVAILABLE THROUGH YOUR RETAILER.; REPLACEMENT PARTS LIST; LOGS
- Page 22 – REPLACEMENT PARTS; BURNER ASSEMBLY
- Page 24 – OBSERVED PROBLEM; POSSIBLE CAUSE; Note: All troubleshooting items are listed in order of operation.; TROUBLESHOOTING
- Page 26 – NOTES
- Page 28 – LEXINGTON FORGE; LIMITED LIFETIME WARRANTY POLICY; LIFETIME WARRANTY; For information about this warranty, contact:; Technical Services
�
�
�
�
�
READ AND SAVE THESE INSTRUCTIONS
MODELS:
C2801VF, C2802VF,
C2803VF, and C2804VF
Natural Gas or
Propane/LPG
Milli-Volt Control
UNVENTED GAS CAST IRON STOVE
INSTALLATION AND OPERATING INSTRUCTIONS
This is an unvented gas-fired heater.
It uses air (oxygen) from the room
in which it is installed. Provisions for
adequate combustion and ventilation
air must be provided. Refer to page 8.
WARNINGS
If the information in this manual is not followed
exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
– Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
– WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use
any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call the
fire department.
– Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
WARNINGS
This appliance may be installed in
an aftermarket, permanently located,
manufactured (mobile) home, where
not prohibited by local codes.
T h i s a p p l i a n c e i s o n l y f o r u s e
with the type of gas indicated on
the rating plate. This appliance is
not convertible for use with other
gases.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 45D0080 45D0080 3 CONTENTS Important Safety Information .............................. 3 Product Features ................................................ 5 Getting Started ................................................... 6 Product Specifications ........................................ 7 Ignit...
2 45D0080 45D0080 3 9. The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.l/NFPA54. 10. This unit complies with ANSI Z21.11.2-2001 Unvented Heaters. 11. Do not install heater in a bathroom or bedroom.12. Correct installation o...
4 45D0080 45D0080 5 � � � � � PRODUCT FEATURES Off/Pilot/On Knob Hi/Lo Knob Data and Instruction Plates Door Figure 1 - Cast Iron Stove Optional Remote Receiver Optional Thermostat Sensor On/Off Switch