Moen TL182 - Manual
A user manual for Moen’s Posi-Temp tub and shower valves covers essential aspects like installation safety, component assembly, and maintenance procedures. The guide emphasizes proper water pressure handling, cartridge retainer clip placement, and detailed steps for rough-in setup–including stop operation types and valve configurations. It also addresses troubleshooting common issues such as reversed installations or debris clearance through flushing routines.
Table of Contents:
- Page 1 – Installation of Tub and Shower Valves
- Page 2 – Shower and Tub Valve Installation and Maintenance
- Page 3 – Faucet Cartridge Adjustment Procedures
- Page 4 – Shower Trim Assembly Installation and Correction
MT692C
INSTALLATION INSTRUCTIONS
THESE INSTRUCTIONS MUST BE
LEFT WITH HOMEOWNER
T187, T188, T189, T190, T191, T628, 2320, 2325, 2339, 2370, 2375, 2389 Series
Models 12189, 12242, 12341, 12342, 62300, TL181, TL182, TL183, TL191
Measurements
These are shown in the drawings.
The depth measurement is critical. Use the front face of the plaster ground as a reference point for the finished wall
position, including tile ( 1-3/4"[44mm] )
. The supply piping centerline should be a maxium of 2" (51mm) and a minimum of 1" (25mm) behind the wall surface.
Use thick wall handle extension kit 96945 for wall thickness 13/16" to 1-13/16". Use handle kit 96955 for wall thickness 1-13/16" to 2-13/16".
Available with and without stops.
Connections are either 1/2 inch I.P.S. pipe or 1/2 inch copper sweat connections.
If the Moen Slip Fit spout is used, a 1/2 inch copper drop and lookout may be used.
POSI-TEMP
TUB AND SHOWER VALVES
Always turn water off before disassembling the valve. Open valve handle to relieve water
pressure and to insure that complete water shut-off has been accomplished.
Before turning water on during either rough-in or trim-out, make sure that cartridge retainer clip is in place.
The cartridge and retainer clip were properly installed and tested before leaving the factory. Although it is unlikely, it is never-
theless possible that through the handling of the valve by any number of persons the retainer clip may not be properly installed.
This should be carefully checked at time of rough-in and trim-out. If the retainer clip is not properly installed, water pressure
could force the cartridge out of the casting. Personal injury or water damage to the premises could result.
RETAINER
CLIP
CAUTION:
Visit Moen's Web Site at www.moen.com
WALL LINE
FACE OF STUD
1-3/4" (44mm)
2-5/16" (59mm) MAX (IPS)
2-3/16" (56mm) MAX (CC)
ESCUTCHEON
SHOWER 45" (1143mm) to 48" (1219mm)
32" (813mm) FOR TUB/SHOWER
COMBINATIONS AND TUB
MODELS ONLY
PLASTER GROUND
KEY STOP
TEMPERATURE
LIMIT STOP
KNOB
HANDLE
KNOB
SCREW
CAP
SCREW
HANDLE
SCREW
HANDLE
ADAPTER
HANDLE
SCREW
KNOB CAP
PLUG
BUTTON
LEVER
HANDLE
FINISHED WALL
SURFACE
STOP
TUBE
WASHER
HANDLE ASSEMBLIES
6'6"
(1981mm)
FLOOR
TUB SPOUT
IMPORTANT: SEE FLUSHING INSTRUC-
TIONS PAGE 2
A
B
C
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Was this manual helpful?
About this manual
- Brand
- Moen
- Model
- TL182
- Document type
- Manual
- Language(s)
- English
- Pages
- 4
- File size
- 263.2 KB
- Format
Summary
Instructions for installing Moen Posi-Temp tub and shower valves, including measurements, component parts, and safety precautions for water pressure and cartridge retainer clip installation.
Procedures for installing and maintaining shower and tub valves, covering stop operation types, rough-in guidelines, flushing instructions, slip-fit spout installation (C.C. and I.P.S. types), valve configurations, cartridge assembly, and safety cautions regarding water supply and soldering.
Step-by-step procedures for disassembling, reassembling, and adjusting the temperature limit stops of a faucet cartridge, including diagrams illustrating component orientation.