Mitsubishi SEZ-KD50VAQ- User Manual

Mitsubishi SEZ-KD50VAQ

Mitsubishi SEZ-KD50VAQ– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
Page: / 40

Table of Contents:

  • Page 2 – PART NAMES AND FUNCTIONS; Indoor Unit; Operation buttons
  • Page 3 – Display; ̊F ̊C; Caution
  • Page 4 – SPECIFICATIONS
  • Page 7 – External static pressure: 15Pa; External static pressure: 5Pa; External static pressure: 50Pa; External static pressure: 35Pa; NOISE CRITERION CURVES
  • Page 11 – NOTE: The sound level is measured in an anechoic room where; Measurement location; test unit
  • Page 12 – INDOOR FAN PERFORMANCE AND CORRECTED AIR FLOW
  • Page 17 – OUTLINES AND DIMENSIONS
  • Page 18 – WIRING DIAGRAM; SYMBOL EXPLANATION
  • Page 19 – REFRIGERANT SYSTEM DIAGRAM; Heat exchanger
  • Page 20 – TROUBLESHOOTING; Lead wires; E D; Wired remote controller; • On wired remote controller.
  • Page 21 – Wireless remote controller; • It is not possible to run the in FAN, DRY or AUTO mode.
  • Page 23 – AUTO RESTART FUNCTION
  • Page 28 – -4. TROUBLESHOOTING BY INFERIOR PHENOMENA; Phenomena
  • Page 31 – Wiring contact check
  • Page 32 – Remove the control box cover according to the; DISASSEMBLY PROCEDURE; Exercise caution when removing heavy parts.
  • Page 33 – filter in the direction of the arrow 1.; Note; Insulation material
  • Page 34 – Remove the drain pan according to the proce-
  • Page 35 – it in the direction of arrow 2.
  • Page 40 – TM
Loading the manual

TECHNICAL & SERVICE MANUAL

CONTENTS

1. PART NAMES AND FUNCTIONS ········2

2. SPECIFICATIONS ·································4

3. OUTLINES AND DIMENSIONS ··········17

4. WIRING DIAGRAM ·····························18

5. REFRIGERANT SYSTEM DIAGRAM·······19

6. TROUBLESHOOTING·························20

7. DISASSEMBLY PROCEDURE ···········32

INDOOR UNIT

Indoor unit
[Model names]

[Service Ref.]

SEZ-KD25VAQ

SEZ-KD25VAQ.TH

SEZ-KD35VAQ

SEZ-KD35VAQ.TH

SEZ-KD50VAQ

SEZ-KD50VAQ.TH

SEZ-KD60VAQ

SEZ-KD60VAQ.TH

SEZ-KD71VAQ

SEZ-KD71VAQ.TH

SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS

WIRED REMOTE

CONTROLLER

(option)

ON/OFF

TEMP.

Model name
indication

No.HWE10080

REVISED EDITION-B

December 2010

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - PART NAMES AND FUNCTIONS; Indoor Unit; Operation buttons

2 1 PART NAMES AND FUNCTIONS Indoor Unit Air outlet duct flange Air outlet Air inlet ● Operation buttons Once the controls are set, the same operation mode can be repeated by simply pressing the ON/OFF button. Wired remote controller (option) PAR-21MAA ON/OFF FILTER CHECK OPERATION CLEAR TEST TEMP. ...

Page 3 - Display; ̊F ̊C; Caution

3 ● Display For purposes of this explanation,all parts of the display are shownas lit. During actual operation, onlythe relevant items will be lit. ˚F˚C ˚F˚C ERROR CODE AFTER TIMER TIME SUN MON TUE WED THU FRI SAT ON OFF Hr AFTER FILTER FUNCTION ONLY1Hr. WEEKLY SIMPLE AUTO OFF Identifies the current...

Page 4 - SPECIFICATIONS

4 2 SPECIFICATIONS kW kW A˚C(˚F) Fan Pa kW m 3 /min mm In.kg mm(in.) A Liquid mm(in.) Gas mm(in.)mm(in.) dB<A> Net weight R410A Motor output Airflow rate(Low-Mid-High) Motor type External finish Wiring Capacity Model Name Power source Optional parts Remark Document Standard attachment Power in...