Mitsubishi RS232/485/LAN Serial Communication Control- User Manual
Mitsubishi RS232/485/LAN Serial Communication Control– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – IntesisBox
- Page 3 – City Multi model; System supervising / controlling; Modbus
- Page 4 – Indoor units; Modbus Master
- Page 5 – General; Virtual signals; Modbus interface; Device type; Points; Configuration
- Page 6 – Extract of the predefined Modbus address table
- Page 9 – LinkBoxMB
- Page 11 – Power
IntesisBox
®
Modbus Server - Mitsubishi Electric G50
datasheet v10 r11 eng
TRADEMARKS: All trademarks and tradenames used in this document are acknowledged to be the copyright of their respective holders.
Gateway for monitor and control Mitsubishi Electric City
Multi Air Conditioning systems from any Modbus master
device TCP or RTU (BMS, PLC, SCADA, HMI, TouchPanel…)
This integration requires the Mitsubishi Electric City Multi AC system be equipped with the Mitsubishi
Electric G-50A or GB-50A gateway. This gateway from Mitsubishi Electric offers the signals of the City
Multi AC system through XML protocol. Every G50 (G-50A or GB-50A) allows access to the signals of up
to 50 City Multi internal units and 50 groups, no matter the number of external units installed. In the G50,
the group is the control unit, every group can have from 1 to 16 associated internal units. This integration
supervises and control groups, not internal units, although if only one internal unit is associated to every
group then you can supervise and control internal units individually. This G50 gateway is supplied by
Mitsubishi Electric. Contact your nearest Mitsubishi Electric distributor for details.
IntesisBox
®
can “
talk”
to up to 4 Mitsubishi Electric G50s using XML protocol and
offers the signals of all these City Multi groups through its Modbus slave
interface, each signal in a predefined fixed Modbus address.
The Modbus interface of IntesisBox can be freely configured as RTU RS232, RTU
RS485 or TCP.
The commissioning of IntesisBox
®
is almost plug & play, only IP parameters of
the box and of G50s have to be configured using
LinkBoxMB
, a friendly software
configuration tool for Windows
TM
suplied along with IntesisBox with no additional
cost.
Master
Modbus
RTU
G50
RS232/RS485
Ethernet
IntesisBox
LinkBoxMB
Configuration
Software
Only needed for configuration
G50
Master
Modbus
TCP
RS232
LAN / WAN
Modbus
TCP
XML
Modbus
RTU
Mitsubishi
Electric
City Multi
Mitsubishi
Electric
City Multi
IntesisBox
®
Modbus Server - Mitsubishi Electric G50
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
IntesisBox ® Modbus Server - Mitsubishi Electric G50 datasheet v10 r11 eng TRADEMARKS: All trademarks and tradenames used in this document are acknowledged to be the copyright of their respective holders. IntesisBox capacity Element Max. Notes Number of G50s 4 Number of independent G50 that can be d...
IntesisBox ® Modbus Server - Mitsubishi Electric G50 datasheet v10 r11 eng TRADEMARKS: All trademarks and tradenames used in this document are acknowledged to be the copyright of their respective holders. Sample applications Integration of Mitsubishi Electric City Multi Air Conditioning systems into...
IntesisBox ® Modbus Server - Mitsubishi Electric G50 datasheet v10 r11 eng TRADEMARKS: All trademarks and tradenames used in this document are acknowledged to be the copyright of their respective holders. Typical applications Integration of Mitsubishi Electric Air Conditioning into Modbus systems. F...