Mitsubishi PU-5TJSA- User Manual

Mitsubishi PU-5TJSA

Mitsubishi PU-5TJSA– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
Page: / 52

Table of Contents:

  • Page 2 – FEATURES; ADVANCED REMOTE CONTROLLER; Every operation condition is indicated on the LED display.; (3) Simultaneous display of set temperature and room temperature; Indoor unit; Ceiling Suspended; Remote controller; Note: Rating condition
  • Page 4 – PART NAMES AND FUNCTION; EASY MAINTENANCE NO MAINTENANCE NECESSARY FOR 2500 HOURS
  • Page 5 – Display Panel; MODE SELECT button
  • Page 6 – SPECIFICATIONS; STANDARD SPECIFICATIONS
  • Page 7 – Indoor unit Service Ref.
  • Page 8 – ELECTRICAL SPECIFICATIONS
  • Page 9 – DATA; Cooling capacity 50Hz
  • Page 11 – Electrical circuit; Frequency
  • Page 12 – OUTLINES AND DIMENSIONS
  • Page 16 – Remote controller cable installation; For exposed remote controller cable installation
  • Page 17 – WIRING DIAGRAM
  • Page 18 – REFRIGERANT SYSTEM DIAGRAM
  • Page 19 – OUTDOOR UNIT; INDOOR UNIT; Strainer
  • Page 20 – Start
  • Page 21 – COOLING OPERATION; during auto vane SWING, the auto vane will continue to swing.
  • Page 22 – DRY OPERATION
  • Page 23 – MICROPROCESSOR CONTROL; OUTLINE OF MICROPROCESSOR CONTROL; REMOTE CONTROLLER; INDOOR CONTROLLER BOARD
  • Page 24 – INDOOR UNIT CONTROL
  • Page 25 – (4) Detecting abnormalities in the outdoor unit; NOTES : Temperature can not be set in FAN operation.
  • Page 26 – DISPLAY SELECT button.
  • Page 27 – -6 Emergency operation; -7 Auto Restart function
  • Page 29 – TROUBLESHOOTING
  • Page 30 – DISASSEMBLY PROCEDURE; OPERATING PROCEDURE; Removing the air intake grill; ward to open the intake grill.; Removing the electrical box; the electrical cover.; Figure 1
  • Page 31 – Figure 2; Removing the side panel; side panel by sliding the panel to the front.; screw; Removing the fan motor; upper side of the casing.; Photo 2
  • Page 32 – Removing the vane motor; Photo 5
  • Page 33 – Removing the drain pan; and left side drain pan.; Removing the guide vane; Photo 8
  • Page 34 – Removing the heat exchanger
  • Page 35 – Amount; Part numbers that are circled not shown in the figure.; PARTS LIST
  • Page 46 – OPTIONAL PARTS; REMOTE CONTROLLER EXTENSION CABLE
  • Page 47 – CENTRALIZED REMOTE CONTROLLER; Allows individual or combined control of up to 16 units.
  • Page 48 – -3 Connection method; Use a
  • Page 49 – Fixing screw holes
  • Page 50 – PROGRAM TIMER ADAPTER; -2 Connection method
  • Page 51 – REMOTE INDICATION ADAPTER; Applicable Service Ref.
Loading the manual

TECHNICAL & SERVICE MANUAL

SPLIT-TYPE, COOLING AIR CONDITIONERS

CONTENTS

1. FEATURES ···········································2

2. PART NAMES AND FUNCTIONS ········4

3. SPECIFICATIONS·································6

4. DATA ·····················································9

5. OUTLINES AND DIMENSIONS··········12

6. WIRING DIAGRAM ·····························17

7. REFRIGERANT SYSTEM DIAGRAM ······18

8. OPERATION FLOW-CHART ··············20

9. MICROPROCESSOR CONTROL·······23

10. TROUBLE SHOOTING ·······················29

11. DISASSEMBLY PROCEDURE ···········30

12. PARTS LIST ········································35

13. OPTIONAL PARTS ·····························46

Indoor unit

PC-2GJA

PC-2.5GJA

PC-3GJA

PC-4GJSA

PC-5GJSA

PC-6GJSA

No. OC134

REVISED EDITION-A

[Model names]

PC-2GJA

1

PC-2.5GJA

1

PC-3GJA

1

PC-4GJSA

1

PC-5GJSA

1

PC-6GJSA

1

[Service Ref.]

This manual does not cover the
following outdoor units. When
serving them, please refer to the
service manual
No.OC127(REVISED EDITION-A) .

[Service Ref.]
PU-2VJA

2

PU-2NJA

1

PU-2.5VJA

2

PU-2.5NJA

1

PU-3NJA

1

PU-3YJA

3

PU-3VJA

2

PU-4TJSA

2

PU-4VLJSA

2

PU-4YJSA

3

INDOOR UNIT

Ceiling Suspended

Series PC

MITSUBISHI ELECTRIC

12

11

10

9

8

7

6

5

4

3

2

1

29

28

27

26

25

24

23

22

21

20

19

18

TIMER

TEMP

TIMER/TEMP.

UP

DOWN

POWER

COOL

ON/OFF

LOUVER

MODE

SELECT

FAN

SPEED

TIMER
MODE

DRY

FAN

HIGH

LOW

ON

AUTO

STOP

START

REMOTE CONTROLLER

The Slim Line.
From Mitsubishi Electric.

1997

1998

PU-5YJSA
PU-5TJSA
PU-6YJSA
PU-6TJSA

Revision:

PC-5GJSA

1

,PC-6GJSA

1

are added

.

The first edition has been par-

tially modified.

Please destroy OC134.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - FEATURES; ADVANCED REMOTE CONTROLLER; Every operation condition is indicated on the LED display.; (3) Simultaneous display of set temperature and room temperature; Indoor unit; Ceiling Suspended; Remote controller; Note: Rating condition

2 1 FEATURES 1. ADVANCED REMOTE CONTROLLER (1) Ultra-thin 12mm (1/2”) remote controller The streamelined, square controller is designed to blend with any inte-rior. Also, the sophisticated microprocessor allows you to easily carryout a wide range of operations. (2) Attractive LED display Every opera...

Page 4 - PART NAMES AND FUNCTION; EASY MAINTENANCE NO MAINTENANCE NECESSARY FOR 2500 HOURS

PART NAMES AND FUNCTION 2 4 Air outlet Intake grille Air intake Left/right guide vanes Change the direction of airflowfrom the horizontal blower. Long-life filter Removes dust and foreigh matter from air coming inthrough the grille (Recommended cleaning interval :Approx, every 2,500 operating hours)...

Page 5 - Display Panel; MODE SELECT button

5 ● Remote controller Settings remain in effect until changed. Airconditioner can be operated by simply pushingON/OFF button once settings have beenmade. MITSUBISHI ELECTRIC 12 11 10 9 8 7 6 5 4 3 2 1 29 28 27 26 25 24 23 22 21 20 19 18 TIMER TEMP TIMER/TEMP. UP DOWN POWER COOL ON/OFF LOUVER MODE SE...

Other Mitsubishi Models