Mitsubishi PKA-RP35GAL- User Manual

Mitsubishi PKA-RP35GAL

Mitsubishi PKA-RP35GAL– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
Page: / 44

Table of Contents:

  • Page 3 – Cautions for units utilizing refrigerant R407C; SAFETY PRECAUTION
  • Page 5 – Cautions for units utilizing refrigerant R410A; CAUTIONS RELATED TO NEW REFRIGERANT; Use new refrigerant pipes.; When charging directly from cylinder
  • Page 7 – PART NAMES AND FUNCTIONS; Indoor Unit
  • Page 8 – When cover is open.; TEMP
  • Page 9 – SPECIFICATIONS; INDOOR UNIT
  • Page 11 – NOISE CRITERION CURVES; High; UNIT
  • Page 12 – OUTLINES AND DIMENSIONS
  • Page 13 – WIRING DIAGRAM; Service board
  • Page 14 – REFRIGERANT SYSTEM DIAGRAM; Heat exchanger
  • Page 15 – TROUBLESHOOTING
  • Page 16 – • The check mode is cancelled.; Malfunction-diagnosis method at maintenance service>; To be continued to the next page.
  • Page 23 – 0-4. TROUBLESHOOTING BY INFERIOR PHENOMENA; Phenomena
  • Page 26 – Vane motor; Thermistor for
  • Page 29 – 0-8. FUNCTIONS OF DIP SWITCH AND JUMPER WIRE
  • Page 30 – SPECIAL FUNCTION; again the former request code No.; System constraint; · This function is available only in rota-; • System constraint; Operation pattern
  • Page 31 – NOTICE; Rotation setting
  • Page 32 – (2) Setting method of each function by wired remote controller
  • Page 33 – DISASSEMBLY PROCEDURE; OPERATION PROCEDURE
  • Page 36 – Set screws
  • Page 38 – To be continued on the next page.
  • Page 39 – From the preceding page.
  • Page 40 – GALH; RoHS; RoHS PARTS LIST
Loading the manual

SERVICE MANUAL

CONTENTS

1. TECHNICAL CHANGES...................................... 2

2. REFERENCE MANUAL....................................... 2

3. SAFETY PRECAUTION....................................... 3

4. PART NAMES AND FUNCTIONS........................ 7

5. SPECIFICATIONS................................................ 9

6. NOISE CRITERION CURVES............................ 11

7. OUTLINES AND DIMENSIONS......................... 12

8. WIRING DIAGRAM............................................. 13

9. REFRIGERANT SYSTEM DIAGRAM......................... 14

10. TROUBLE SHOOTING....................................... 15

11. SPECIAL FUNCTION......................................... 30

12. DISASSEMBLY PROCEDURE........................... 33

13. PARTS LIST........................................................ 37

14. RoHS PARTS LIST............................................. 40

Indoor unit

[Model names]

PKA-RP35GAL

PKA-RP50GAL

[Service Ref.]

PKA-RP35GAL

PKA-RP35GAL#1

PKA-RP50GAL

PKA-RP50GAL#1

Indoor unit

No.OC330

REVISED EDITION-B

Remote controller

SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS
SPLIT-TYPE, AIR CONDITIONERS

Model name
indication

PKH-P35GALH

PKH-P50GALH

PKH-P35GALH

PKH-P50GALH

May 2008

Revision :

• PKA-RP35·50GAL#1 are
added in REVISEDEDITION-B

.

• Some discriptions have been
modified.

• Please void OC330
REVISED EDITION-A.

Note :

This manual describes only

service data of the indoor
units.

• RoHS compliant products

have <G> mark on spec
name plate.

For servicing of RoHS
compliant products, refer to

the RoHS Parts List.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 3 - Cautions for units utilizing refrigerant R407C; SAFETY PRECAUTION

3 Cautions for units utilizing refrigerant R407C 3-2. CAUTIONS RELATED TO NEW REFRIGERANT Do not use the existing refrigerant piping. The old refrigerant and lubricant in the existing piping contains a large amount of chlorine which may cause the lubricant deterioration of the new unit. Use “low res...

Page 5 - Cautions for units utilizing refrigerant R410A; CAUTIONS RELATED TO NEW REFRIGERANT; Use new refrigerant pipes.; When charging directly from cylinder

5 Cautions for units utilizing refrigerant R410A CAUTIONS RELATED TO NEW REFRIGERANT Use new refrigerant pipes. Make sure that the inside and outside of refrige-rant piping is clean and it has no contaminationsuch as sulfur hazardous for use, oxides, dirt, shaving particles, etc.In addition, use pip...

Page 7 - PART NAMES AND FUNCTIONS; Indoor Unit

77 4 PART NAMES AND FUNCTIONS Indoor Unit Air intake Air intake grille Filter Air outlet Guide vane Auto vane

Other Mitsubishi Models