Page 3 - Table of Contents; OUTDOOR UNITS; ILATON; TOOLS; INDOOR UNITS; • Standard compliance: All Mitsubishi Electric products
3 Table of Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2Overview of CITY MULTI ® . . . . . . . . . . . . . . . . . . . . 4 System Components . . . . . . . . . . . . . . . . . . . . . . . . 6 Technology Overview . . . . . . . . . . . . . . . . . . . . . . 10Low...
Page 4 - ductless, or ducted commercial or
4 CITY MULTI ® VRF (Variable Refrigerant Flow) Zoning Systems: user-friendly ductless, or ducted commercial or residential comfort control systems. Quality and reliability from a name you know: Mitsubishi Electric CITY MULTI is the first two-pipe, simultaneous cooling and heating system available in...
Page 5 - CITY MULTI OVERVIEW
5 Easy to install, easier to operate CITY MULTI is a simple, two-pipe system with easy, non-polar, two-wire control connections. Because of the modular outdoor unit’s compact design, transportation can be transported through a standard, six-person elevator during the building process. This translate...
Page 6 - simultaneously cools; water-source systems with VRF technology. These; Hyper-Heating INVERTER; Providing up
6 OUTDOOR UNITS CITY MULTI ® System Components Mitsubishi Electric HVAC has an extensive outdoor unit line-up that can be tailored to any building design need. Choose from modular units that have capacities up to 30 tons for Y-Series heat pump systems or 20 tons for R2-Series heat recovery systems, ...
Page 7 - CONTROLS NETWORK; Hydronic Heat
7 CONTROLS NETWORK CITY MULTI Controls Network (CMCN) Mitsubishi Electric’s M-NET communication bus allows CMCN to deliver precise temperature control to each individual zone. The M-NET allows for a simple installation and configuration of CMCN components. The flexibility of CMCN allows building own...
Page 8 - TONS; I I I I I I; PUMY
PURY-P72TJMU-A PUHY-P72TJMU-A PUHY-P72TJMU-A 8 TONS 3.5 4 4.5 5 8 10 12 16 20 24 26 30 TONS I I I I I I I I I I I I Btu/h 42k 48k 54k 60k 96k 120k 144k 192k 240k 288k 312k 360k Btu/h Y-Series H2i ® Heat Pump PUHY-HP-T/Y(S)JMU-A WR2-Series Heat Recovery (Water-source) PQRY / PQHY R2-Series Heat Recov...
Page 9 - Cooling; SYSTEM COMPONENTS
PUHY-P96TJMU-A PUHY-P120TJMU-A PURY-P96TJMU-A PURY-P240TJMU-A 9 TONS 3.5 4 4.5 5 8 10 12 16 20 24 26 30 TONS I I I I I I I I I I I I Btu/h 42k 48k 54k 60k 96k 120k 144k 192k 240k 288k 312k 360k Btu/h 288k 360k 240k 360k 320k 403k 216k 270k 405k Cooling Heating 192k SYSTEM COMPONENTS
Page 10 - Outdoor Temperature
10 CITY MULTI Revit ® Objects Autodesk ® Revit ® building information modeling (BIM) software is helping engineers, architects, and construction professionals explore early design concepts and forms and more accurately maintain a vision through design, documentation, and construction. In mid-2009, R...
Page 11 - like no other; Additional features; Long line length; Easy maintenance
11 100% 4% 15Hz Cooling:18-75Hz Heating:15-88Hz Heating / Cooling Capacity Linear Capacity Control Compressor Frequency * image 100% INVERTER-driven, like no other The compressor varies its speed to match the indoor cooling or heating demand and, therefore only consumes the energy that is required. ...
Page 12 - LOW AMBIENT COOLING OPTION; PATENT PENDING; Mitsubishi Electric is the first; low ambient cooling solution; for its 6–30 ton air source; General features
12 LOW AMBIENT COOLING OPTION PATENT PENDING The low ambient cooling kit makes it possible to provide 100% cooling capacity at outdoor temperatures down to -10 o F while still allowing full airflow at higher ambient temperatures and full heating capacity if the unit switches to that mode . The kits ...
Page 13 - LOW AMBIENT SPECIFICATIONS
13 LOW AMBIENT SPECIFICATIONS PUHY-HP Outdoor Temperature Extended Cooling Range Indoor T emperarur e Standard COOLING Range ° FWB 86 77 68 59 50 41 ° CWB 30 25 20 15 10 5 -10 0 FDB 0 0 FDB -25 -20 -15 -10 -5 0 5 10 15 20 25 30 35 40 45 50 0 CDB -13 -4 5 14 23 32 41 50 59 68 77 86 95 104 113 122 0 F...
Page 14 - FPO IMAGE TO COME; Leading the vrf industry; HIGH EFFICIENCY
14 FPO IMAGE TO COME Leading the vrf industry Mitsubishi Electric HVAC has been at the forefront of the charge to develop proper testing standards and procedures for VRF systems, providing clients the necessary information to properly incorporate these systems into their building designs. AHRI Stand...
Page 15 - TABLE 1
15 HIGH EFFICIENCY TABLE 1 Electrically Operated Variable Refrigerant Flow Air-to-Air and Applied Heat Pumps–Minimum Efficiency Requirements Equipment Type Size Category Heating Section Type Sub-Category or Rating Condition Minimum Efficiency Test Procedure VRF Air Cooled, (cooling mode) <65,000 ...
Page 16 - Heat Recovery
16 The R2-Series simultaneously cools and heats different zones within a building to provide energy-saving, heat-recovery operation through the use of the BC Controller. The R2-Series can support up to 50 indoor units. Modular units feature low operating sound, easy piping and maintenance design, an...
Page 17 - CITY MULTI; Increased pipe length; • Single BC Controller:; Advantages of CITY MULTI two-pipe systems; Refrigerant piping lengths; Vertical differentials between units
17 CITY MULTI Two-Pipe Heat Recovery System Refrigerant Distribution Units Indoor Units OTHER MANUFACTURERS SYSTEM Outdoor Unit Outdoor Unit BC Controller 17 Increased pipe length The R2-Series system offers flexibility and reduced costs for refrigerant piping. The system may have a maximum total le...
Page 18 - R2-SERIES SPECIFICATIONS
18 R2-SERIES SPECIFICATIONS Model Name 208/230V PURY-P72TJMU-A (-BS) PURY-P96TJMU-A (-BS) PURY-P120TJMU-A (-BS) PURY-P144TJMU-A (-BS) 460V PURY-P72YJMU-A (-BS) PURY-P96YJMU-A (-BS) PURY-P120YJMU-A (-BS) PURY-P144YJMU-A (-BS) Power source 208 / 230V, 3-Phase, 60Hz / 460V, 3-Phase, 60Hz Capacity (Nomi...
Page 20 - BC CONTROLLER SPECIFICATIONS
20 CMB-P-NU-GA/HA (Main BC) Specifications Model Name CMB-P108NU-GA CMB-P1010NU-GA CMB-P1013NU-GA CMB-P1016NU-HA Number of Branches 8 10 13 16 Power Source 208/230V, 1-phase, 60 Hz Power Input Cooling W 112 138 178 274/353 Heating W 53 66 86 137/177 Current (208/230V) Cooling A 0.54/0.49 0.66/0.60 0...
Page 21 - BC CONTROLLERS; BV-Series Ball Valves
21 CMB-P-NU-GB, HB (Sub BC) Specifications Model Name CMB-P104NU-GB CMB-P108NU-GB CMB-P1016NU-HB *2 Number of Branches 4 8 16 Power Source 208/230V, 1-phase, 60 Hz Power Input Cooling W 53 106 314 Heating W 27 53 157 Current (208/230V) Cooling A 0.25/0.23 0.51/0.46 1.17/1.37 Heating A 0.13/0.12 0.25...
Page 22 - Heat Pump
22 Y-SERIES OVERVIEW Y-Series outdoor units are flexible enough to cool or heat up to 50 individual zones, maximizing building design options. They feature low operating sound, easy piping and maintenance design, and light weight. Y-Series units are available in both 208/230V and 460V up to 30 tons ...
Page 23 - Y-SERIES SPECIFICATIONS
23 23 OUTDOOR UNITS Y-SERIES SPECIFICATIONS Model Name 208/230V PUHY-P72TJMU-A (-BS) PUHY-P96TJMU-A (-BS) PUHY-P120TJMU-A (-BS) PUHY-P144TJMU-A (-BS) 460V PUHY-P72YJMU-A (-BS) PUHY-P96YJMU-A (-BS) PUHY-P120YJMU-A (-BS) PUHY-P144YJMU-A (-BS) Power source 208 / 230V, 3-Phase, 60Hz / 460V, 3-Phase, 60H...
Page 26 - Setting a new standard; Light; The technology behind
26 H2i ™ Y-SERIES OVERVIEW Hyper Heating Inverter vs. Others 96,000 Btuh size, 70 0 FWB entering indoor unit Hyper-heat (High Heat Setting)Hyper-heat (Standard Setting)Traditional Heat Pump Technology 100% @ 0 0 F Setting a new standard in performance The Hyper-Heating INVERTER Y-Series combines the...
Page 28 - S-Series two-pipe cooling or heating system
28 S-SERIES OVERVIEW The CITY MULTI S-Series is a single- phase heat pump system that is perfect for light commercial or large residential applications. Available in 36,000 or 48,000 Btu/h, the S-Series can provide cooling or heating for up to eight individual zones. The CITY MULTI S-Series provides...
Page 29 - S-SERIES SPECIFICATIONS
29 S-SERIES SPECIFICATIONS Model Name PUMY-P36NHMU(-BS) PUMY-P48NHMU(-BS) Power Source 208/230V, 1-phase, 60Hz Capacity *1 Cooling Btu/h 36,000 48,000 Heating Btu/h 40,000 54,000 Power Input Cooling kW 3.22 4.97 Heating kW 2.93 4.88 Current (208-230V) Cooling A 14.2/15.7 24.0/21.7 Heating A 12.9/14....
Page 30 - Typical closed-loop; Double heat recovery
30 New W-Series modular units combine the convenience of water-source systems with VRF technology. These units are 30% smaller than previous models and are easily installed indoors, which means that system performance efficiency is independent of outdoor ambient temperatures. The W-Series includes W...
Page 32 - W-SERIES SPECIFICATIONS; WR2-Series Heat Recovery Water-source Unit
32 W-SERIES SPECIFICATIONS WR2-Series Heat Recovery Water-source Unit (Requires BC Controller - refer to specifications on pages 20 - 21) Model Name 208/230V PQRY-P72THMU-A PQRY-P96THMU-A PQRY-P120THMU-A 460V PQRY-P72YHMU-A PQRY-P96YHMU-A PQRY-P120YHMU-A Power source 208 / 230V, 3-Phase, 60Hz / 460V...
Page 37 - WATER HEATING
37 PWFY OVERVIEW (Hydronic Heat Exchanger) Hot and cold water, quickly and efficiently. PWFY: Hydronic Heat Exchanger The PWFY Hydronic Heat Exchanger is available in two configurations, the HEX (-AU) and the Booster (-BU). Each provides unique solutions to incorporate into an existing VRF system fo...
Page 38 - PWFY OVERVIEW
38 PWFY OVERVIEW (continued) 12:00 AM 4:00 AM 8:00 AM 12:00 PM 4:00 PM 8:00 PM Load (BTUH) Sample Hotel Cooling And Hot Water Demand Per Hour Time Of Days 10000 12000 14000 8000 6000 4000 2000 0 Cooling Load (BTUH)Hot Water Load (BTUH) Mitsubishi Hydronic Heat ExchangerGas Hot Water Heater Electric ...
Page 41 - Customize your CITY MULTI building comfort solution
41 41 INDOOR UNITS PVFY: Vertical-concealed The PVFY vertical air handler is designed for closet or attic applications. The side drain pan makes it possible to use in a horizontal, left facing, position. With all the components, including a linear expansion valve (LEV) and controls pre-mounted withi...
Page 45 - Auto Wave airflow feature; ADDITIONAL FEATURES FOR PLFY-NBMU MODELS; Corner-pocket design simplifies; Independent vane motor control; Auto; sensor accessory
45 Auto Wave airflow feature (Heating Mode) In the Heating mode on the PLFY-NBMU, each air outlet vane operates independently, distributing warm air in multiple directions for better room heating. ADDITIONAL FEATURES FOR PLFY-NBMU MODELS Corner-pocket design simplifies maintenance and installation P...
Page 48 - Ideal for small spaces; Compact and lightweight
48 PMFY OVERVIEW (ceiling-recessed cassette) Capacity range: 6,000 – 15,000 Btu/h Quiet operation Newly-developed airflow control technology operates as low as 27 dB(A) for industry-leading quiet performance. Drain lift-up mechanism The drain pipe can be extended anywhere up to 23-5/8 " above th...
Page 51 - PCFY SPECIFICATIONS
51 51 PCFY SPECIFICATIONS INDOOR UNITS Model Name PCFY-P15NKMU-E PCFY-P24NKMU-E PCFY-P30NKMU-E PCFY-P36NKMU-E Power Source 208 / 230V, 1 Phase, 60Hz Cooling Capacity Btu/h *1 15,000 24,000 30,000 36,000 Heating Capacity Btu/h *1 17,000 27,000 34,000 40,000 Power Consumption Cooling W 30 40 90 110 He...
Page 52 - Operating Sound Range
52 PEFY OVERVIEW (ceiling-concealed) Quiet operation thanks to a specially designed centrifugal fan PEFY-P-NMAU-E PEFY-P-NMSU-E 22-28 23-30 23-35 28-33 30-37 30-40 PEFY-P-NMHU-E P54 P72 P96 36-41 35-41 38-43 38-44 47 54 P54 36-45 26-29 28-34 28-35 29-36 30-38 32-41 35-44 PEFY-P-NMAU-E PEFY-P-NMSU-E ...
Page 55 - FBM SERIES FILTER BOXES; FBM Series Filter Boxes
55 INDOOR UNITS FBM SERIES FILTER BOXES FBM Series filter boxes FB Series filter boxes are available in compatable sizes for all Mr. Slim horizontal ducted indoor units. FBM2 boxes include 2" thick pleated MERV 13 filter(s) installed. Filters are tested in accordance with ANSI/ASHRAE Standard 52...
Page 57 - Low Profile Indoor Units; INDOOR UNITS INDOOR UNITS
57 FBL SERIES FILTER BOXES FBL Series filter boxes FBL1 filter boxes include 1" thick pleated MERV 8 filter(s). Filters are tested in accordance with ANSI/ASHRAE Standard 52.2 and Rated Class 2 under U.L. Standard 900 The cabinet is constructed of non-insulated 20 gauge G-60 galvanized steel wit...
Page 60 - Vertical Airflow
60 PVFY OVERVIEW (vertical-concealed) Ideal for closet or attic applications. The Vertical Air Handler The PUFY Vertical Air Handler is ideal for installations in closets or equipment rooms where space is limited. It also has a side drain pan allowing it to be installed in a horizontal left position...
Page 63 - CONTROLS; iPhone Mobile Application
63 CITY MULTI ® CONTROLS NETWORK CONTROLS iPhone Mobile Application The meZO (Mitsubishi Electric Zone) controller App allows for the monitoring and controlling of Mitsubishi Electric HVAC systems. This level of access can be utilized by building or campus managers, maintenance per-sonnel, building ...
Page 64 - CENTRALIZED CONTROLLER AG-150; AG-150 Software Options; AG-150 Optional Accessories
64 CENTRALIZED CONTROLLER AG-150 Option: Black surface cover. PAC-YG71CBL AG-150 PAC-SC51KUA ETHERNET M-NET Function Description Touch Screen 9" high resolution color touch screen Max No. of Indoor Units Up to 50 indoor units can be connected ON/OFF On/Off operation for a single group and batch ...
Page 65 - CENTRALIZED CONTROLLER GB-50ADA; GB-50ADA Software Options
65 CONTROLS DIDO Board ETHERNET Function Description Max No. of Indoor Units Up to 50 indoor units can be connected ON/OFF On/Off operation for a single group and batch operation Operation Mode Cool/Dry/Auto/Fan/ Heat. Auto mode is available with only R2 and WR2 systems Temperature Setting Set tempe...
Page 66 - CENTRALIZED CONTROLLER TC-24
66 CENTRALIZED CONTROLLER TC-24 TC-24 DIDO Board Function Description Max No. of Indoor Units Up to 24 indoor units can be connected ON/OFF On/Off operation for a single group and batch operation Operation Mode Cool/Dry/Auto/Fan/ Heat/Setback. Auto mode is available with only R2 and WR2 systems Temp...
Page 67 - CENTRALIZED CONTROLLER GB-24; GB-24 Software Options
67 CENTRALIZED CONTROLLER GB-24 GB-24 DIDO Board ETHERNET Function Description Max No. of Indoor Units Up to 24 indoor units can be connected ON/OFF On/Off operation for a single group and batch operation Operation Mode Cool/Dry/Auto/Fan/ Heat/Setback. Auto mode is available with only R2 and WR2 sys...
Page 68 - CONTROLS NETWORK SPECIFICATIONS
68 CONTROLS NETWORK SPECIFICATIONS Model Local remote controller PAR21MAA PAR-F27MEA PAC-Y151CRB PAR-FL32MAA AG-150 50 / 50 GB-50ADA 50 / 50 GB24 24 / 24 TC-24 TG-2000 *4*5 2000 / 2000 Controlable Grougs/Indoors(Groups/Indoors) 1 / 16 1 / 16 1 / 16 1 / 16 AG-150 AG-150 GB-24 Browser *4 GB24 Browser ...
Page 69 - SOFTWARE OPTIONS FOR CENTRALIZED CONTROLLERS
69 The Centralized Controllers support operations that supersede control of the remote controllers and include system configuration, daily/weekly scheduling, operation, and malfunction monitoring. All Centralized Controllers are equipped with an RJ-45 Ethernet port to support interconnection with a ...
Page 71 - PAC-YG66DCA Digital Input Digital Output (DIDO) Control Board
71 CONTROLS I/O CONTROL BOARD Function Description Inputs Qty 2 digital inputs (non-voltage contacts) Outputs Qty 2 digital outputs (non-voltage relay contact)Use only VDC with outputs Monitor Status, FaultRequires AG-150, GB-50ADA, GB-24 or TC-24 Centralized Controller Control On/Off, Start/Stop, E...
Page 74 - LonWorks; BACnet
74 SYSTEM INTEGRATION: LONWORKS ® AND BACNET ® The CMCN supports integration with Building Management Systems (BMS) via our LonWorks ® and BACnet ® interfaces. LonWorks ® Interface The Mitsubishi Electric HVAC LonWorks ® interface, LMAP03U, supports up to 50 indoor units with a variety of network va...
Page 75 - Lossnay energy recovery; VENTILATION
75 LOSSNAY ENERGY ® RECOVERY VENTILATORS Improved sound attenuation makes Lossnay ® units quiet enough for places where silence is a must, such as meeting rooms and libraries. A free-cooling function is standard to help reduce costs and boost efficiency. The integrated bypass damper design makes ins...
Page 78 - VENTILATION: Dedicated Outdoor Air Systems; Y Series; CITY MULTI DOAS; Dedicated Outdoor; R2 Series
78 VENTILATION: Dedicated Outdoor Air Systems The PEFY-AF Dedicated Outside Air System comes in two configurations, the CFM and the CFMR. Both configurations offer a high capacity coil that will condition incoming outsideair, making it suitable to be distributed to down–stream fan coil units. P120 P...
Page 80 - MAINTENANCE TOOL SOFTWARE OVERVIEW
80 Mitsubishi’s easy-to-use, Windows ® based Maintenance Tool software allows technicians to monitor and collect CITY MULTI system data and control various functions of the system for maintenance purposes. System monitoring is accomplished through direct connection between your PC and the M-NET bus ...
Page 81 - SOFTWARE
81 SOFTWARE The system connection information view shows a snapshot of the components connected to the system, identifying each component’s type and system address. Through a simple series of clicks, the user can monitor the critical data points for each component, manipulate the control features an...
Page 82 - DESIGN TOOL SOFTWARE OVERVIEW
82 DESIGN TOOL SOFTWARE OVERVIEW Mitsubishi’s Design Tool software makes designing with CITY MULTI quick and easy. The designer just needs to drag and drop components to complete the design. The program has built–in safeguards against exceeding limitations and shows if there is an error. Assuring li...