Mitsubishi PFFY-NEMU-A- User Manual

Mitsubishi PFFY-NEMU-A

Mitsubishi PFFY-NEMU-A– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
Page: / 25

Table of Contents:

  • Page 2 – SAFETY PRECAUTIONS; Before installation and electric work; Symbols used in the text; Carefully read the labels affixed to the main unit.
  • Page 3 – Precautions for devices that use
  • Page 4 – Models; FEATURES; Concealed type
  • Page 5 – Remote controller; PART NAMES AND FUNCTIONS; Exposed type
  • Page 7 – SPECIFICATION
  • Page 9 – OUTLINES AND DIMENSIONS
  • Page 11 – WIRING DIAGRAM
  • Page 12 – Liquid pipe; REFRIGERANT SYSTEM DIAGRAM
  • Page 13 – TROUBLE SHOOTING
  • Page 14 – Thermistor R; Linear expansion valve; Operation summary of the linear expansion valve.
  • Page 15 –
  • Page 16 – Make sure that power source is turning off.; Indoor unit control board; ) Indoor unit address setting rule is different by each field work.; Indoor unit do not run without address setting in field.
  • Page 17 – the; unit
  • Page 18 – DISASSEMBLY PROCEDURE; Be careful removing heavy parts.; OPERATING PROCEDURE
  • Page 19 – Removing the side casing; Removing the thermistor
  • Page 20 – Thermistor; Removing the drainpan; Removing the thermistor; PHOTOS
  • Page 22 – Removing the casing
  • Page 23 – Removing the casing ass’y
  • Page 25 – 400 Lawrenceville Suwanee Road; Specifications are subject to change without notice.
Loading the manual

TECHNICAL & SERVICE MANUAL

Air-Conditioners For Building Application

<Indoor unit>

2005

Models

PFFY-P06NRMU-E,PFFY-P08NRMU-E
PFFY-P12NRMU-E,PFFY-P15NRMU-E
PFFY-P18NRMU-E,PFFY-P24NRMU-E
PFFY-P06NEMU-E,PFFY-P08NEMU-E
PFFY-P12NEMU-E,PFFY-P15NEMU-E
PFFY-P18NEMU-E,PFFY-P24NEMU-E

CONTENTS

SAFETY PRECAUTIONS ························· 1

1. FEATURES ··········································· 3

2. PART NAMES AND FUNCTIONS ········ 4

3. SPECIFICATION ··································· 6

4. OUTLINES AND DIMENSIONS············ 8

5. WIRING DIAGRAM ····························· 10

6. REFRIGERANT SYSTEM DIAGRAM ····11

7. TROUBLE SHOOTING ······················· 12

8. DISASSEMBLY PROCEDURE ··········· 17

Floor Standing Type

Series PFFY

For use with the R410A & R22

Exposed type

Concealed type

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - SAFETY PRECAUTIONS; Before installation and electric work; Symbols used in the text; Carefully read the labels affixed to the main unit.

1 SAFETY PRECAUTIONS and install the unit at the specified place. - Improper installation may cause the unit to topple and result in injury. • Always use an air cleaner, humidifier, electric heater, and otheraccessories specified by Mitsubishi Electric. - Ask an authorized technician to install the ...

Page 3 - Precautions for devices that use

2 2. Precautions for devices that use Caution: • Do not use the existing refrigerant piping. - The old refrigerant and refrigerator oil in the existing piping con- tains a large amount of chlorine which may cause the refrigeratoroil of the new unit to deteriorate. • Use refrigerant piping made of C1...

Page 4 - Models; FEATURES; Concealed type

3 PFFY-P06NEMU-E,PFFY-P06NRMU-E PFFY-P08NEMU-E,PFFY-P08NRMU-E PFFY-P12NEMU-E,PFFY-P12NRMU-E PFFY-P15NEMU-E,PFFY-P15NRMU-E PFFY-P18NEMU-E,PFFY-P18NRMU-E PFFY-P24NEMU-E,PFFY-P24NRMU-E 1.8 / 2.0 2.3 / 2.6 3.5 / 4.0 4.4 / 5.0 5.3 / 5.9 7.0 / 7.9 Floor Standing Type Series PFFY Models Cooling capacity/He...

Other Mitsubishi Models