Mitsubishi MXZ-24UV-E1- User Manual
Mitsubishi MXZ-24UV-E1– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – OUTDOOR UNIT; Air inlet; Model indication; PART NAMES AND FUNCTIONS
- Page 3 – INDOOR / OUTDOOR CORRESPONDENCE TABLE; There is no combination other than this table.; Combination of the connectable indoor units
- Page 4 – NOTE: Electrical data is for outdoor unit only.; INDOOR UNITS COMBINATION
- Page 6 – SPECIFICATION
- Page 7 – NOISE CRITERIA CURVES; OCT; BAND CENTER FREQUENCIES, Hz
- Page 8 – OUTLINES AND DIMENSIONS
- Page 9 – WIRING DIAGRAM
- Page 10 – REFRIGERANT SYSTEM DIAGRAM
- Page 11 – PERFORMANCE CURVES
- Page 12 – -2.Capacity and input correction by inverter output frequency
- Page 13 – -3.Outdoor low pressure and outdoor unit current
- Page 17 – MICROPROCESSOR CONTROL; INVERTER MULTI SYSTEM CONTROL
- Page 21 – 0-5.Discharge temperature protection control
- Page 23 – TROUBLESHOOTING; Troubleshooting procedure; Lead wiring
- Page 27 – Check of serial signal; Check of power supply
- Page 31 – Check of HPS; The other cases; then turn them back ON.; • When the operation frequency does not go up from lowest frequency.
- Page 32 – TEST POINT DIAGRAM AND VOLTAGE
- Page 33 – Short
- Page 34 – Photo 1; DISASSEMBLY INSTRUCTIONS; Photo 3
- Page 35 – Photo 4
- Page 36 – Photo 6
- Page 37 – PARTS LIST
- Page 40 – OPTIONAL PARTS; Copyright 2001 MITSUBISHI ELECTRIC ENGINEERING CO.,LTD
SERVICE MANUAL
CONTENTS
1. PART NAMES AND FUNCTIONS ······················2
2. INDOOR/OUTDOOR
CORRESPONDENCE TABLE ···························3
3. INDOOR UNITS COMBINATION ·······················4
4. SPECIFICATION·················································6
5. NOISE CRITERIA CURVES ······························ 7
6. OUTLINES AND DIMENSIONS ························ 8
7. WIRING DIAGRAM ············································9
8. REFRIGERANT SYSTEM DIAGRAM ··············10
9. PERFORMANCE CURVES ······························11
10. MICROPROCESSOR CONTROL ····················17
11. TROUBLESHOOTING ······································23
12. DISASSEMBLY INSTRUCTIONS·····················34
13. PARTS LIST······················································37
14. OPTIONAL PARTS ······················BACK COVER
Inverter-controlled multi system
Model
MXZ-24UV -
E1
No. OB287
This manual describes technical data of the outdoor unit.
For the indoor unit refer to the service manuals No. OB229, OB227 REVISED EDITION-B, OB252, OB212,
OB239 and OC165 of corresponding models.
Model indication
SPLIT-TYPE, HEAT PUMP AIR CONDITIONER
OB287--1.qxp 10/9/01 3:29 PM Page 1
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
OUTDOOR UNIT Air inlet Air outlet (back and side) Model indication MXZ-24UV- E1 2 PART NAMES AND FUNCTIONS 1 OB287--1.qxp 10/9/01 3:29 PM Page 2
3 2 INDOOR / OUTDOOR CORRESPONDENCE TABLE ❈ There is no combination other than this table. MXZ-24UV- E1 OUTDOOR UNIT Combination of the connectable indoor units 07+07 07+09 07+12 07+18 09+09 09+12 09+18 12+12 12+18 18+18 07+07+07 07+07+09 07+07+12 07+07+18 07+09+09 07+09+12 07+09+18 09+09+09 09+09+1...
4 07 09 12 18 07+07 07+09 07+12 07+18 09+09 09+12 09+18 12+12 12+18 18+18 07+07+07 07+07+09 07+07+12 07+07+18 07+09+09 07+09+12 07+09+18 09+09+09 09+09+12 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 3.62 4.35 6.96 11.11 7.44 7.83 11.01 14.40 9.18 13.19 14.40 14.40 14.40 14.4...