Mitsubishi MUZ-FD12NA-U1 - User Manual
Mitsubishi MUZ-FD12NA-U1 – User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 3 – Air outlet
- Page 4 – SPECIFICATION; NOTE
- Page 5 – Test condition; OPERATING RANGE
- Page 6 – OUTLINES AND DIMENSIONS; REQUIRED SPACE
- Page 7 – WIRING DIAGRAM
- Page 8 – REFRIGERANT SYSTEM DIAGRAM; MAX. REFRIGERANT PIPING LENGTH and MAX. HEIGHT DIFFERENCE
- Page 9 – DATA
- Page 10 – Cooling; Heating
- Page 14 – -5. CAPACITY AND INPUT CORRECTION BY INVERTER OUTPUT FREQUENCY
- Page 15 – ACTUATOR CONTROL; -3. RELATION BETWEEN MAIN SENSOR AND ACTUATOR
- Page 16 – SERVICE FUNCTIONS; TROUBLESHOOTING
- Page 23 – B Check of open phase
- Page 25 – G Check of outdoor thermistors; Unit operates COOL mode even if it is set to HEAT mode.
- Page 29 – M How to check miswiring and serial signal error
- Page 30 – N Electromagnetic noise enters into TV sets or radios
- Page 31 – Back side of unit
- Page 32 – OPERATING PROCEDURE; Removing the cabinet; DISASSEMBLY INSTRUCTIONS
- Page 33 – Removing the discharge temperature thermistor,; Photo 3
- Page 34 – Removing outdoor fan motor
- Page 36 – TM
SERVICE MANUAL
CONTENTS
1. TECHNICAL CHANGES ··································· 3
2. PART NAMES AND FUNCTIONS ····················· 3
3. SPECIFICATION ················································ 4
4. OUTLINES AND DIMENSIONS ························ 6
5. WIRING DIAGRAM ············································ 7
6. REFRIGERANT SYSTEM DIAGRAM ··············· 8
7. DATA ·································································· 9
8. ACTUATOR CONTROL ··································· 15
9. SERVICE FUNCTIONS ··································· 16
10. TROUBLESHOOTING ····································· 16
11. DISASSEMBLY INSTRUCTIONS ···················· 32
Models
MUZ-FD09NA
MUZ-FD09NA-
U1
MUZ-FD12NA
MUZ-FD12NA-
U1
SPLIT-TYPE AIR CONDITIONERS
OUTDOOR UNIT
Indoor unit service manual
MSZ-FD•NA Series (OBH497)
NOTE:
RoHS compliant products have <G> mark on the spec name plate.
TM
HFC
utilized
R410A
No. OBH498
REVISED EDITION-B
PARTS CATALOG (OBB498)
Revision B:
• 7. DATA has been corrected.
Please void OBH498 REVISED EDITION-A.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Other Manuals for Mitsubishi MUZ-FD12NA-U1
Summary
33 1 TECHNICAL CHANGES MUZ-FD09NA MUZ-FD09NA - U1 MUZ-FD12NA MUZ-FD12NA - U1 1. New model PART NAMES AND FUNCTIONS 2 MUZ-FD09NA MUZ-FD12NA Air outlet Drain outlet Piping Drain hose Air inlet
4 3 SPECIFICATION Outdoor unit model MUZ-FD09NA MUZ-FD12NA Capacity Rated (Minimum~Maximum) Cooling 1 Btu/h 9,000 (2,800~9,000) 12,000 (2,800~12,000) Heating 47 1 Btu/h 10,900 (3,000~18,000) 13,600 (3,000~21,000) Capacity Rated Heating 17 2 Btu/h 12,500 13,600 Power consumption Rated (Minimum~Maximu...
5 Test condition ARI Mode Test Indoor air condition (°F) Outdoor air condition (°F) Dry bulb Wet bulb Dry bulb Wet bulb SEER (Cooling) "A" Cooling Steady State at rated compressor Speed 80 67 95 (75) "B-2" Cooling Steady State at rated compressor Speed 80 67 82 (65) "B-1" Coo...