Mitsubishi MUY-GE12NA- User Manual
Mitsubishi MUY-GE12NA– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Job Name:
Location:
Date:
Purchaser:
Engineer:
Submitted to:
For
Approval
Unit Designation:
Schedule No.:
Zoning
Cooling*
Rated Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12,000 Btu/h
Minimum Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3,800 Btu/h
SEER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20.5 Btu/h/W
Total Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .960 W
*
Rating Conditions (Cooling) - Indoor: 80ºF (27ºC) DB, 67ºF (19ºC) WB; Outdoor: 95ºF
(35ºC) DB, 75ºF (24ºC) WB.
Electrical Requirements
Power Supply . . . . . . . . . . . . . . . . . . . . 208 / 230V, 1-Phase, 60 Hz
Breaker Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 A
Voltage
Indoor - Outdoor S1-S2 . . . . . . . . . . . . . . . . . . . . . . AC 208 / 230V
Indoor - Outdoor S2-S3 . . . . . . . . . . . . . . . . . . . . . . . . . DC 12-24V
Indoor - Remote Controller . . . . . . . . . . . . . . . . . . . . . . . . . Wireless
OPERATING RANGE
Indoor Intake Air Temp. Outdoor Intake Air Temp.
Cooling
Maximum
90
°
F (32
°
C) DB,
73
°
F (23
°
C) WB
115
°
F (46
°
C) DB
Minimum
67
°
F (19
°
C) DB,
57
°
F (14
°
C) WB
14
°
F (-10
°
C) DB
Indoor Unit
MCA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 A
Fan Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.76 F.L.A.
Airfl ow (Quiet - Lo - Med - Hi - Super Hi)
Cooling . . . . . . . . . . . . . . . . 145 - 170 - 237 - 321 - 399 Dry CFM
109 - 134 - 201 - 286 - 364 Wet CFM
Sound Pressure Level (Quiet - Lo - Med - Hi - Super Hi)
Cooling . . . . . . . . . . . . . . . . . . . . . . . . 19 - 22 - 30 - 37 - 45 dB(A)
DIMENSIONS
UNIT INCHES / MM
W
31-7/16 / 799
D
9-1/8 / 232
H
11-5/8 / 295
Weight. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 lbs. / 10 kg
External Finish . . . . . . . . . . . . . . . . . . . . .Munsell No. 1.0Y 9.2 / 0.2
Field Drainpipe Size O.D. . . . . . . . . . . . . . . . . . . . . . 5/8" / 15.88 mm
Remote Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Wireless
(Optional Wired Remote Controller PAR-21MAA;
see Data Submittal Sheet)
Outdoor Unit
Compressor . . . . . . . . . . . . . . . . . . . . . . . . . . . . .DC Inverter-driven
MCA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 A
Fan Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.50 F.L.A.
Sound Pressure Level
Cooling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 dB(A)
DIMENSIONS
INCHES / MM
W
31-1/2 / 800
D
11-1/4 / 286
H
21-5/8 / 549
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 lbs. / 35 kg
External Finish . . . . . . . . . . . . . . . . . . . . . . Munsell No. 3Y 7.8 / 1.1
Refrigerant Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R410A
Refrigerant Pipe Size O.D.
Gas Side . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3/8" / 9.52 mm
Liquid Side. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1/4" / 6.35 mm
Max. Refrigerant Pipe Length. . . . . . . . . . . . . . . . . . . . . 65 ft. / 20 m
Max. Refrigerant Pipe Height Difference . . . . . . . . . . . . 40 ft. / 12 m
Connection Method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Flared
SUBMITTAL DATA: MSY-GE12NA & MUY-GE12NA
12,000 BTU/H WALL-MOUNTED AIR-CONDITIONING SYSTEMS
OPTIONAL ACCESSORIES
Outdoor Unit
• Drain Socket Assembly (MAC-860DS)
Indoor Unit
• M-NET Control Adapter (MAC-399IF)
• MA Contact Terminal Interface (MAC-397IF)
• Wired Remote Controller (PAR-21MAA; requires MAC-397IF)
• Condensate Pump (230V; SI3100-230)
• Anti-allergy Enzyme Filter (Two pieces per set; MAC-408FT-E)
GENERAL FEATURES
• Wall-mounted indoor unit
• Standard Hybrid Catechin Prefi lter is included with indoor unit
• Quiet operation
• Choice of fan speeds: Quiet, Low, Medium, High, and Super High;
Auto fan speed control also included
• Wireless remote controller is included; PAR-21MAA wired
remote controller can be installed as an option
• Indoor unit powered from outdoor unit using A-Control
• Auto restart following a power outage
• Limited warranty: fi ve years on parts and defects and seven years
on the compressor
Indoor Unit: MSY-GE12NA
Wireless Remote
Controller
Outdoor Unit: MUY-GE12NA
Reference
Construction