Mitsubishi Mr.Slim PKA-A.HA4- User Manual

Mitsubishi Mr.Slim PKA-A.HA4

Mitsubishi Mr.Slim PKA-A.HA4– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
Page: / 36

Table of Contents:

  • Page 2 – REFERENCE MANUAL
  • Page 3 – SAFETY PRECAUTION; Cautions for units utilising refrigerant R410A; Use new refrigerant pipes.; Be sure to use a filter drier for new refrigerant.
  • Page 4 – PART NAMES AND FUNCTIONS; Indoor unit; Filter
  • Page 5 – Wired; °F°C; Display Section
  • Page 6 – IR wireless
  • Page 7 – SPECIFICATIONS
  • Page 8 – NOISE CRITERION CURVES; UNIT
  • Page 9 – OUTLINES AND DIMENSIONS
  • Page 10 – WIRING DIAGRAM
  • Page 11 – REFRIGERANT SYSTEM DIAGRAM; Heat exchanger
  • Page 12 – TROUBLESHOOTING
  • Page 13 – Malfunction-diagnosis method at maintenance service>; Display the error code on the self-check result display screen.; IR wireless remote controller
  • Page 20 – -4. TROUBLESHOOTING BY INFERIOR PHENOMENA
  • Page 22 – Normal; Thermistor R
  • Page 23 – Wiring contact check; Sensor signal check
  • Page 24 – Indoor controller board; CNMF
  • Page 25 – -8. FUNCTIONS OF DIP SWITCH AND JUMPER WIRE
  • Page 26 – SPECIAL FUNCTION; again the former request code No.; Outline of functions; Main unit; System constraint
  • Page 27 – · This function is available only in cooling mode.; NOTE; Rotation setting
  • Page 28 – (2) Setting method of each function by wired remote controller; TEST
  • Page 29 – DISASSEMBLY PROCEDURE; Be careful when removing heavy parts.; Push; Corner hole; right side as shown in the figure 1.; PHOTOS & ILLUSTRATIONS
  • Page 30 – PHOTOS
  • Page 32 – panel at right lower side.; REMOVING THE ROOM TEMPERATURE THERMISTOR
  • Page 36 – TM
Loading the manual

SERVICE MANUAL

SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS
SPLIT-TYPE, AIR CONDITIONERS

NOTE:
• This manual describes

only service data of the
indoor units.

• RoHS compliant products

have <G> mark on the
spec name plate.

CONTENTS

1. REFERENCE MANUAL................................... 2
2. SAFETY PRECAUTION................................... 3
3. PART NAMES AND FUNCTIONS................... 4
4. SPECIFICATIONS............................................ 7
5. NOISE CRITERION CURVES.......................... 8
6. OUTLINES AND DIMENSIONS....................... 9
7. WIRING DIAGRAM.........................................10
8. REFRIGERANT SYSTEM DIAGRAM............ 11
9. TROUBLESHOOTING.................................... 12
10. SPECIAL FUNCTION .....................................26
11. DISASSEMBLY PROCEDURE.......................29

Indoor unit

[Model names] [Service Ref.]

PARTS CATALOG (OCB483)

No. OCH483

November 2010

INDOOR UNIT

PKA-A12HA4

PKA-A12HA4

PKA-A18HA4

PKA-A18HA4

ON/OFF

TEMP.

COOL

DRY

AUTO

FAN

HEAT

WIRED REMOTE

CONTROLLER

(Option)

IR WIRELESS REMOTE
CONTROLLER (Option)

3 3 2 2 3

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - REFERENCE MANUAL

2 1 REFERENCE MANUAL 1-1. OUTDOOR UNIT SERVICE MANUAL Service Ref. Service Manual No. PUZ-A18/24/36NHA4PUZ-A18/24/36NHA4-BSPUY-A12/18/24/36NHA4PUY-A12/18/24/36NHA4-BS OCH481 OCB481 Radio frequency interface Wired remote controller IR wireless remote controller ON/OFF TEMP. COOL DRY AUTO FAN HEAT RF ...

Page 3 - SAFETY PRECAUTION; Cautions for units utilising refrigerant R410A; Use new refrigerant pipes.; Be sure to use a filter drier for new refrigerant.

3 SAFETY PRECAUTION 2 Cautions for units utilising refrigerant R410A 2-2. CAUTIONS RELATED TO NEW REFRIGERANT Use new refrigerant pipes. Store the piping to be used indoors during installation, and keep both ends of the piping sealed until just before brazing. (Leave elbow joints, etc. in their pack...

Page 4 - PART NAMES AND FUNCTIONS; Indoor unit; Filter

4 Gravimeter Unit [3] Service tools Use the below service tools as exclusive tools for R410A refrigerant. 3 PART NAMES AND FUNCTIONS Indoor unit Filter Air intake Louver Air outlet Vane No. Tool name Specifications 1 Gauge manifold · Only for R410A· Use the existing fitting specifications. (UNF1/2)·...

Other Mitsubishi Models