Mitsubishi Mr.Slim PCA-A.KA4- User Manual

Mitsubishi Mr.Slim PCA-A.KA4

Mitsubishi Mr.Slim PCA-A.KA4– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
Page: / 52

Table of Contents:

  • Page 2 – REFERENCE SERVICE MANUAL
  • Page 3 – SPECIFICATIONS
  • Page 10 – OUTLINES AND DIMENSIONS; Floor; Detail drawing of fresh air intake hole
  • Page 13 – Please be sure when installing the drain lift up
  • Page 16 – OUTDOOR UNIT; PIPING-WIRING DIRECTION
  • Page 17 – Example of Notes
  • Page 19 – WIRED REMOTE CONTROLLER
  • Page 20 – WIRELESS REMOTE CONTROLLER; COOL
  • Page 21 – WIRING DIAGRAM
  • Page 22 – SETTING
  • Page 24 – Be sure to turn off the source power
  • Page 30 – REFRIGERANT SYSTEM DIAGRAM; Thermistor TH1; Heat exchanger
  • Page 33 – PERFORMANCE CURVES; CAP; Cooling performance curve
  • Page 34 – Heating performance curve; INDOOR
  • Page 35 – CORRECTION FACTORS; Outdoor unit; Cooling; ft; Corrected pipe length
  • Page 36 – -1. OUTLET AIR SPEED AND COVERAGE RANGE; AIR FLOW DATA
  • Page 37 – Fresh air intake hole diagram
  • Page 38 – How to read curves
  • Page 39 – Change of outlet numbers; The optional air outlet is necessary.; Branch duct and change of outlet numbers; Air flows in 2 directions.
  • Page 42 – Fresh air intake hole; Indoor unit
  • Page 43 – INDOOR FAN PERFORMANCE AND CORRECTED AIR FLOW
  • Page 45 – NOISE CRITERION CURVES
  • Page 46 – UNIT
  • Page 47 – High
  • Page 48 – unit
  • Page 49 – Measurement location; test unit
  • Page 52 – OPTIONAL PARTS
Loading the manual

TECHNICAL DATA BOOK

<Indoor unit>

[Model names]

R410A

PLA-A·BA
PKA-A·HA
PKA-A·HAL
PKA-A·KA
PKA-A·KAL
PCA-A·KA
PEA-A·AA

<Outdoor unit>

[Model names]

No. OCS14

SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS
SPLIT-TYPE, AIR CONDITIONERS

PUZ-A18/24/30/36/42NHA3
PUZ-A18/24/30/36/42NHA3-BS
PUY-A12/18/24/30/36/42NHA3
PUY-A12/18/24/30/36/42NHA3-BS

March 2009

INVERTER

CONTENTS

1. REFERENCE SERVICE MANUAL ............................................. 2
2. SPECIFICATIONS ....................................................................... 3
3. OUTLINES AND DIMENSIONS ................................................ 10
4. WIRING DIAGRAM ................................................................... 21
5. REFRIGERANT SYSTEM DIAGRAM ...................................... 30
6. PERFORMANCE CURVES ...................................................... 33
7. CORRECTION FACTORS ........................................................ 35
8. AIR FLOW DATA ...................................................................... 36
9. NOISE CRITERION CURVES .................................................. 45
10. OPTIONAL PARTS .................................................... Back cover

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - REFERENCE SERVICE MANUAL

2 For information on service, please refer to the service manual as follows. 1-1. INDOOR UNIT Model name Service Ref. Service Manual No. PLA-A12/18/24/30/36/42BA PLA-A12/18/24/30/36/42BA 1 OCH420 OCB420 HWE08070 BWE0811A PCA-A24/30/36/42KA PCA-A24/30/36/42KA PEA-A12/18AA PEA-A12/18AA.TH OCH455 OCB45...

Page 3 - SPECIFICATIONS

3 2 SPECIFICATIONS 2-1. CEILING CASSETTE TYPE Model name Indoor unit Outdoor unit Cooling Max. Capacity Btu/h Rated Capacity Btu/h Min. Capacity Btu/h Total Input W EER Btu/h/W SEER Btu/h/W Moisture Removal Pints/h *1 SHF Heating Max. Capacity Btu/h Rated Capacity Btu/h Min. Capacity Btu/h Total Inp...

Page 10 - OUTLINES AND DIMENSIONS; Floor; Detail drawing of fresh air intake hole

10 INDOOR UNITPLA-A12BA PLA-A18BA PLA-A24BA PLA-A30BA PLA-A36BA PLA-A42BA 3 OUTLINES AND DIMENSIONS Unit: inch (mm) 14-27/32 11-3/16 2-3/8 +5 0 (7.5) (160) (500) (950) Floor Min.94-1/2(2400) from floor Entire periphery (36) (83) (83) (36) (500) (950) (597) (597) ( 158) ( : 175) (350) ( : 150) ( 14- ...

Other Mitsubishi Models