Mitsubishi Mr.Slim MSZ-D30NA- User Manual

Mitsubishi Mr.Slim MSZ-D30NA

Mitsubishi Mr.Slim MSZ-D30NA– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
Page: / 44

Table of Contents:

  • Page 3 – PART NAMES AND FUNCTIONS; Piping; TECHNICAL CHANGES
  • Page 4 – SPECIFICATION
  • Page 5 – Test condition; OPERATING RANGE
  • Page 6 – REQUIRED SPACE; OUTLINES AND DIMENSIONS
  • Page 7 – WIRING DIAGRAM
  • Page 11 – REFRIGERANT SYSTEM DIAGRAM
  • Page 12 – MAX. REFRIGERANT PIPING LENGTH and MAX. HEIGHT DIFFERENCE
  • Page 13 – ) COOLING CAPACITY; DATA
  • Page 14 – Cooling
  • Page 16 – Heating
  • Page 18 – -5. CAPACITY AND INPUT CORRECTION BY INVERTER OUTPUT FREQUENCY
  • Page 20 – -3. Relation between main sensor and actuator; ACTUATOR CONTROL
  • Page 21 – Changing defrost finish temperature; SERVICE FUNCTIONS
  • Page 22 – Lead wiring; TROUBLESHOOTING
  • Page 29 – MUZ
  • Page 30 – A How to check inverter/compressor
  • Page 31 – B Check of outdoor thermistors
  • Page 35 – H How to check miswiring and serial signal error
  • Page 37 – K Electromagnetic noise enters into TV sets or radios
  • Page 40 – Outdoor power board
  • Page 41 – OPERATING PROCEDURE; Removing the cabinet; Photo 2; DISASSEMBLY INSTRUCTIONS
  • Page 42 – power board; Photo 6
  • Page 43 – Removing outdoor fan motor; Photo 8
  • Page 44 – Removing the compressor and 4-way valve; Removing the reactor
Loading the manual

SERVICE MANUAL

CONTENTS

1. TECHNICAL CHANGES ··································· 3
2. PART NAMES AND FUNCTIONS ····················· 3
3. SPECIFICATION ················································ 4
4. OUTLINES AND DIMENSIONS ························ 6
5. WIRING DIAGRAM ············································ 7
6. REFRIGERANT SYSTEM DIAGRAM ··············11
7. DATA ································································ 13
8. ACTUATOR CONTROL ··································· 20
9. SERVICE FUNCTIONS ··································· 21

10. TROUBLESHOOTING ····································· 22
11. DISASSEMBLY INSTRUCTIONS ···················· 41

Models

MUZ-D30NA

/

-

1

/

-

U1

/

-

U2

MUZ-D36NA

/

-

1

/

-

U1

/

-

U2

MUY-D30NA

/

-

1

MUY-D36NA

/

-

1

SPLIT-TYPE AIR CONDITIONERS

OUTDOOR UNIT

Indoor unit service manual

MSZ-D•NA Series (OBH501)
MSY-D•NA Series (OBH501)

NOTE:

RoHS compliant products have <G> mark on the spec name plate.

TM

HFC

utilized

R410A

No. OBH502

REVISED EDITION-B

PARTS CATALOG (OBB502)

Revision B:

• MUZ-D•NA-

1

/-

U2

and MUY-D•NA-

1

have

been corrected.

Please void OBH502 REVISED EDITION-A.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 3 - PART NAMES AND FUNCTIONS; Piping; TECHNICAL CHANGES

3 MUZ-D30NA MUZ-D30NA- U1 MUZ-D36NA MUZ-D36NA- U1 MUY-D30NA MUY-D36NA 1. New model MUZ-D30NA → MUZ-D30NA- 1 MUZ-D30NA- U1 → MUZ-D30NA- U2 MUZ-D36NA → MUZ-D36NA- 1 MUZ-D36NA- U1 → MUZ-D36NA- U2 MUY-D30NA → MUY-D30NA- 1 MUY-D36NA → MUY-D36NA- 1 1. Wiring diagram has been changed.2. Fan motor has been ...

Page 4 - SPECIFICATION

4 Item Model MSZ-D30NA MSY-D30NA MSZ-D36NA MSY-D36NA Capacity Rated (Minimum ~ Maximum) Cooling 1 Btu/h 30,700 (9,800 ~ 30,700) 30,700 (9,800 ~ 30,700) 32,000/33,200 (9,800 ~ 32,000) / (9,800 ~ 33,200) 33,200/34,600 (9,800 ~ 33,200) / (9,800 ~ 34,600) Heating 47 1 32,600 (8,700 ~ 34,000) — 35,200 (8...

Page 5 - Test condition; OPERATING RANGE

5 Test condition ARI Mode Test Indoor air condition (°F) Outdoor air condition (°F) Dry bulb Wet bulb Dry bulb Wet bulb SEER (Cooling) "A" Cooling Steady State at rated compressor Speed 80 67 95 (75) "B-2" Cooling Steady State at rated compressor Speed 80 67 82 (65) "B-1" Coo...

Other Mitsubishi Models