Mitsubishi Mr.Slim MSZ-A12NA- User Manual

Mitsubishi Mr.Slim MSZ-A12NA

Mitsubishi Mr.Slim MSZ-A12NA– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
57 Page 57
58 Page 58
59 Page 59
60 Page 60
61 Page 61
62 Page 62
63 Page 63
64 Page 64
65 Page 65
66 Page 66
67 Page 67
68 Page 68
69 Page 69
70 Page 70
71 Page 71
72 Page 72
73 Page 73
74 Page 74
75 Page 75
76 Page 76
77 Page 77
78 Page 78
79 Page 79
80 Page 80
81 Page 81
82 Page 82
83 Page 83
84 Page 84
Page: / 84

Table of Contents:

  • Page 3 – Refrigerant system diagram has been changed.; TECHNICAL CHANGES
  • Page 4 – INFORMATION FOR THE AIR CONDITIONER WITH R410A REFRIGERANT; Compressor
  • Page 5 – Tools dedicated for the air conditioner with R410A refrigerant
  • Page 6 – PART NAMES AND FUNCTIONS
  • Page 7 – NOTE; SPECIFICATION
  • Page 10 – OPERATING RANGE
  • Page 11 – REQUIRED SPACE; OUTLINES AND DIMENSIONS
  • Page 12 – WIRING DIAGRAM
  • Page 20 – REFRIGERANT SYSTEM DIAGRAM
  • Page 22 – MAX. REFRIGERANT PIPING LENGTH and MAX. HEIGHT DIFFERENCE
  • Page 23 – ) COOLING CAPACITY; SHC is based on 80; ) COOLING CAPACITY CORRECTIONS; DATA
  • Page 25 – Cooling; Heating
  • Page 35 – -5. CAPACITY AND INPUT CORRECTION BY INVERTER OUTPUT FREQUENCY
  • Page 37 – -3. RELATION BETWEEN MAIN SENSOR AND ACTUATOR; ACTUATOR CONTROL
  • Page 38 – CHANGE IN DEFROST SETTING; JS; TROUBLESHOOTING; Lead wiring; SERVICE FUNCTIONS
  • Page 39 – Outline of the function
  • Page 40 – Operational procedure
  • Page 41 – Outdoor unit failure mode table
  • Page 47 – A How to check inverter/compressor
  • Page 48 – B Check of open phase; D Check of compressor
  • Page 52 – I Check of outdoor fan motor
  • Page 53 – J Check of power supply
  • Page 54 – K Check of current-limiting resistor
  • Page 57 – N How to check miswiring and serial signal error
  • Page 58 – O Electromagnetic noise enters into TV sets or radios
  • Page 59 – P Check of bus-bar voltage
  • Page 60 – Back side of unit; Fin temperature; Front side of unit; Rotational frequency feedback signal of outdoor fan motor CN931)
  • Page 64 – Outdoor power board
  • Page 65 – Removing the cabinet; DISASSEMBLY INSTRUCTIONS
  • Page 66 – to the reactor and the following connectors:; Photo 3; Heat sink
  • Page 67 – Removing outdoor fan motor
  • Page 69 – board and power board; CN661 (Discharge temperature thermistor, defrost; Photo 4; Screws of the relay panel
  • Page 70 – (5) Pull out the discharge temperature thermistor from its; Photo 5; Discharge temperature thermistor
  • Page 71 – Removing the compressor and 4-way valve; Recover gas from the pipes until the pressure; Photo 8; Screws of the reactor
  • Page 72 – OUTDOOR UNIT STRUCTURAL PARTS AND FUNCTIONAL PARTS; PARTS LIST
  • Page 73 – Part numbers that are circled are not shown in the illustration.
  • Page 74 – OUTDOOR UNIT ELECTRICAL PARTS
  • Page 76 – PARTS
  • Page 79 – RoHS
  • Page 84 – OPTIONAL PARTS
Loading the manual

SERVICE MANUAL

CONTENTS

1. TECHNICAL CHANGES ··································· 3
2. PART NAMES AND FUNCTIONS ····················· 6
3. SPECIFICATION ················································ 7
4. OUTLINES AND DIMENSIONS ·······················11
5. WIRING DIAGRAM ·········································· 12
6. REFRIGERANT SYSTEM DIAGRAM ············· 20
7. DATA ································································ 23
8. ACTUATOR CONTROL ··································· 37
9. SERVICE FUNCTIONS ··································· 38

10. TROUBLESHOOTING ····································· 38
11. DISASSEMBLY INSTRUCTIONS ···················· 65
12. PARTS LIST ····················································· 72

12-1. PARTS LIST ··········································· 72
12-2. RoHS PARTS LIST ································ 78

13. OPTIONAL PARTS ······················ BACK COVER

Models

MUZ-A09NA

,-

1

,-

U1

,-

U2

MUZ-A12NA

,-

U1

MUZ-A15NA

,-

U1

MUZ-A17NA

,-

U1

MUZ-A24NA

,-

1

,-

U1

,-

U2

MUY-A15NA

MUY-A17NA

MUY-A24NA

,-

1

,-

U1

,-

U2

MUZ-GA24NA

,-

U1

MUY-GA24NA

SPLIT-TYPE AIR CONDITIONERS

OUTDOOR UNIT

Indoor unit service manual

MSZ-A•NA Series (OB450)

MSZ-GA•NA Series (OB450)

MUZ-A09/12/15/17NA
MUY-A15/17NA

NOTE:

RoHS compliant products have <G> mark on the spec name plate.

For servicing of RoHS compliant products, refer to the PARTS LIST

(RoHS compliant).

TM

HFC

utilized

R410A

No. OB451

REVISED EDITION-E

Revision E:

• MUZ-GA24NA and MUY-GA24NA have

been added.

Please void OB451 REVISED EDITION-D.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 3 - Refrigerant system diagram has been changed.; TECHNICAL CHANGES

3 MUZ09UN → MUZ-A09NA MUZ12UN → MUZ-A12NA MUH15TN → MUZ-A15NA MUH17TN → MUZ-A17NA MUH24WN → MUZ-A24NA MU15TN → MUY-A15NA MU17TN → MUY-A17NA MU24WN → MUY-A24NA 1. Outdoor unit model has been changed.2. Control method between indoor and outdoor unit has been changed.3. Refrigerant has been changed. (R...

Page 4 - INFORMATION FOR THE AIR CONDITIONER WITH R410A REFRIGERANT; Compressor

4 INFORMATION FOR THE AIR CONDITIONER WITH R410A REFRIGERANT • This room air conditioner adopts HFC refrigerant (R410A) which never destroys the ozone layer. • Pay particular attention to the following points, though the basic installation procedure is same as that for R22 air condition- ers. As R41...

Page 5 - Tools dedicated for the air conditioner with R410A refrigerant

5 -22 -4 14 32 50 68 86 104 122 140 -73 0 73 145 218 290 363 435 508 580 (PSIG) R410A R22 Conversion chart of refrigerant temperature and pressure Saturated liquid pressure (°F) 1. Tools dedicated for the air conditioner with R410A refrigerant The following tools are required for R410A refrigerant. ...

Other Mitsubishi Models