Mitsubishi Mr.Slim MSY-GE15NA- User Manual

Mitsubishi Mr.Slim MSY-GE15NA

Mitsubishi Mr.Slim MSY-GE15NA– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
57 Page 57
58 Page 58
Page: / 58

Table of Contents:

  • Page 2 – TECHNICAL CHANGES
  • Page 3 – PART NAMES AND FUNCTIONS
  • Page 4 – NOTE; SPECIFICATION
  • Page 7 – Test condition
  • Page 8 – REQUIRED SPACE; OUTLINES AND DIMENSIONS
  • Page 10 – WIRING DIAGRAM
  • Page 15 – REFRIGERANT SYSTEM DIAGRAM
  • Page 17 – MAX. REFRIGERANT PIPING LENGTH and MAX. HEIGHT DIFFERENCE
  • Page 18 – DATA; ) COOLING CAPACITY CORRECTIONS
  • Page 19 – Cooling capacity
  • Page 23 – Data is based on the condition of outdoor humidity 75%.
  • Page 28 – -5. CAPACITY AND INPUT CORRECTION BY INVERTER OUTPUT FREQUENCY
  • Page 30 – The fan motor turns ON/OFF, interlocking with the compressor.; -3. RELATION BETWEEN MAIN SENSOR AND ACTUATOR; ACTUATOR CONTROL
  • Page 31 – TROUBLESHOOTING; components for bursting and discoloration.; SERVICE FUNCTIONS
  • Page 32 – Outline of the function
  • Page 33 – Operational procedure
  • Page 37 – fl; B Check of open phase
  • Page 39 – G Check of outdoor thermistors; Unit operates COOL mode even if it is set to HEAT mode.
  • Page 40 – I Check of outdoor fan motor
  • Page 41 – J Check of power supply
  • Page 44 – M How to check miswiring and serial signal error
  • Page 45 – N Electromagnetic noise enters into TV sets or radios
  • Page 46 – Back side of unit; VAC
  • Page 49 – OPERATING PROCEDURE; Removing the cabinet; (1) Slide the sleeve and check if there is a locking lever or not.; DISASSEMBLY INSTRUCTIONS
  • Page 50 – Photo 6
  • Page 53 – Photo 3
  • Page 56 – Photo 4
  • Page 58 – TM
Loading the manual

SERVICE MANUAL

CONTENTS

1. TECHNICAL CHANGES ··································· 2
2. PART NAMES AND FUNCTIONS ····················· 3
3. SPECIFICATION ················································ 4
4. OUTLINES AND DIMENSIONS ························ 8
5. WIRING DIAGRAM ·········································· 10
6. REFRIGERANT SYSTEM DIAGRAM ············· 15
7. DATA ································································ 18
8. ACTUATOR CONTROL ··································· 30
9. SERVICE FUNCTIONS ··································· 31

10. TROUBLESHOOTING ····································· 31
11. DISASSEMBLY INSTRUCTIONS ···················· 49

Models

MUZ-GE09NA

MUZ-GE12NA

MUZ-GE15NA

MUZ-GE18NA

MUZ-GE24NA

MUY-GE09NA

MUY-GE12NA

MUY-GE15NA

MUY-GE18NA

MUY-GE24NA

SPLIT-TYPE AIR CONDITIONERS

OUTDOOR UNIT

Indoor unit service manual

MSZ-GE•NA MSY-GE•NA Series (OBH548)

NOTE:

RoHS compliant products have <G> mark on the spec name plate.

TM

HFC

utilized

R410A

No. OBH549

REVISED EDITION-B

PARTS CATALOG (OBB549)

Revision B:

Descriptions regarding the outdoor fan motor

have been corrected.
Please void OBH549 REVISED EDITION-A.

MUZ-GE09/12/15NA
MUY-GE09/12/15NA

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - TECHNICAL CHANGES

2 MUZ-GE09NAMUZ-GE12NAMUZ-GE15NAMUZ-GE18NAMUZ-GE24NAMUY-GE09NAMUY-GE12NAMUY-GE15NAMUY-GE18NAMUY-GE24NA 1. New model 1 TECHNICAL CHANGES Revision B: • Descriptions regarding the outdoor fan motor have been corrected. Revision A: • MUZ-GE24NA and MUY-GE24NA have been added.

Page 3 - PART NAMES AND FUNCTIONS

3 MUZ-GE09NA MUZ-GE12NA MUZ-GE15NA MUY-GE09NA MUY-GE12NA MUY-GE15NA Air outlet Drain outlet Piping Drain hose Air inlet (back and side) MUZ-GE18NA MUY-GE18NA Piping Air outlet Drain hose Drain outlet Air inlet (back and side) 2 PART NAMES AND FUNCTIONS MUZ-GE24NA MUY-GE24NA Piping Air outlet Drain o...

Page 4 - NOTE; SPECIFICATION

4 Outdoor unit model MUZ-GE09NA MUY-GE09NA MUZ-GE12NA MUY-GE12NA Capacity Rated (Minimum~Maximum) Cooling 1 Btu/h 9,000 ( 3,800 ~ 12,200 ) 9,000 ( 3,800 ~ 12,200 ) 12,000 ( 3,800 ~ 13,600 ) 12,000 ( 3,800 ~ 13,600 ) Heating 47 1 Btu/h 10,900 ( 4,500 ~ 14,100 ) — 14,400 ( 5,500 ~ 18,100 ) — Capacity ...

Other Mitsubishi Models