Mitsubishi MCFZ-A18WV- User Manual

Mitsubishi MCFZ-A18WV

Mitsubishi MCFZ-A18WV– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
Page: / 52

Table of Contents:

  • Page 2 – TECHNICAL CHANGES; Refrigerating; INFORMATION FOR THE AIR CONDITIONER WITH R410A REFRIGERANT; Compressor
  • Page 3 – NOTE : The unit of pressure has been changed to MPa on the; Can R22 tools be used?; Tools dedicated for the air conditioner with R410A refrigerant
  • Page 5 – PART NAMES AND FUNCTIONS; OUTDOOR UNIT; ACCESSORIES; SPECIFICATION
  • Page 7 – Specifications and rating conditions of main electric parts
  • Page 8 – NOISE CRITERIA CURVES
  • Page 9 – OUTLINES AND DIMENSIONS; Service panel; REQUIRED SPACE
  • Page 10 – WIRING DIAGRAM; RED; MF; MC; MODELS WIRING DIAGRAM
  • Page 11 – MODEL WIRING DIAGRAM
  • Page 12 – REFRIGERANT SYSTEM DIAGRAM
  • Page 13 – MAX. HEIGHT DIFFERENCE; MAX. REFRIGERANT PIPING LENGTH
  • Page 14 – PERFORMANCE CURVES; (1) GUARANTEED VOLTAGE; INDOOR UNIT
  • Page 16 – OUTDOOR LOW PRESSURE AND OUTDOOR UNIT CURRENT; Air flow : High speed
  • Page 17 – HEAT operation; Condition indoor: Dry bulb temperature 20.0°C
  • Page 18 – PERFORMANCE DATA COOL operation
  • Page 22 – Rated frequency 88Hz
  • Page 24 – Rated frequency 102Hz
  • Page 26 – Rated frequency 63Hz
  • Page 28 – PERFORMANCE DATA HEAT operation
  • Page 29 – ACTUATOR CONTROL; -3. Relation between main sensor and actuator
  • Page 30 – Troubleshooting procedure; the components for bursting and discoloration.; Take care the following during servicing.; Housing point; TROUBLESHOOTING
  • Page 32 – Troubleshooting check table
  • Page 34 – Trouble criterion of main parts
  • Page 35 – Check of power supply
  • Page 40 – Check of HPS; Infinity; • When the operation frequency does not go up from lowest frequency.
  • Page 43 – V DC pulse wave
  • Page 44 – DISASSEMBLY INSTRUCTIONS; Removing the cabinet
  • Page 45 – and power board; thermistor and outdoor heat exchanger; Photo 4; Screws of the relay panel
  • Page 46 – Propeller; OPERATING PROCEDURE; (6) Pull out the outdoor heat exchanger temperature thermistor; Photo 5; Discharge temperature thermistor
  • Page 47 – Photo 8; Welded parts of 4-way valve; Removing the compressor and 4-way valve; Recover gas from the pipes until the pressure; Removing the reactor; Screws of the reactor; Photo 9
  • Page 48 – PARTS LIST; FUNCTIONAL PARTS
  • Page 49 – Part numbers that are circled are not shown in the illustration.
  • Page 52 – Copyright 2004 MITSUBISHI ELECTRIC ENGINEERING CO.,LTD
Loading the manual

SERVICE MANUAL

CONTENTS

1. TECHNICAL CHANGES ····································2

2. PART NAMES AND FUNCTIONS ······················5

3. SPECIFICATION·················································5

4. NOISE CRITERIA CURVES ·······························8

5. OUTLINES AND DIMENSIONS ·························9

6. WIRING DIAGRAM ··········································10

7. REFRIGERANT SYSTEM DIAGRAM ··············12

8. PERFORMANCE CURVES ······························14

9. ACTUATOR CONTROL····································29

10. TROUBLESHOOTING ······································30

11. DISASSEMBLY INSTRUCTIONS ·····················44

12. PARTS LIST······················································48

Wireless type
Models

SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS

MUZ-A18YV -
MUZ-A24YV -
MUZ-A26YV -

E1

E1

E1

MUZ-A18YV -
MUZ-A24YV -
MUZ-A26YV -

E1

E1

E1

Indication of
model name

HFC

utilized

R410A

Revision A:

MUZ-A18YV -

can be connected to

MCFZ-A18WV -

.

MUZ-A24YV -

can be connected to

MCFZ-A24WV -

.

E1

E1

E1

E1

No. OB346

REVISED EDITION-A

Please void OB346.

NOTE:
This service manual describes technical data of the outdoor units.
•As for indoor units MSZ-A18YV -

, MSZ-A24YV -

and MSZ-A26YV -

, refer to the

service manual OB345.

•As for indoor units MCFZ-A18WV -

and MCFZ-A24WV -

, refer to the service manual

OB344 REVISED EDITION-A.

E1

E1

E1

E1

E1

OB346A --1qxp 04.6.14 1:20 PM Page 1

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - TECHNICAL CHANGES; Refrigerating; INFORMATION FOR THE AIR CONDITIONER WITH R410A REFRIGERANT; Compressor

2 1 TECHNICAL CHANGES Refrigerating oil Refrigerant New refrigerant R410A HFC-32: HFC-125 (50%:50%) Pseudo-azeotropic refrigerant Not included A1/A1 72.6 -51.4 1.557 64 Non combustible 0 1730 From liquid phase in cylinder Possible Incompatible oil Non Non Previous refrigerant R22 R22 (100%) Single r...

Page 3 - NOTE : The unit of pressure has been changed to MPa on the; Can R22 tools be used?; Tools dedicated for the air conditioner with R410A refrigerant

3 -30 -20 -10 0 10 20 30 40 50 60 -0.5 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 (MPa [Gauge]) R410A R22 Conversion chart of refrigerant temperature and pressure Saturated liquid pressure ( : ) NOTE : The unit of pressure has been changed to MPa on the international system of units(SI unit system). The co...

Page 5 - PART NAMES AND FUNCTIONS; OUTDOOR UNIT; ACCESSORIES; SPECIFICATION

5 PART NAMES AND FUNCTIONS 2 OUTDOOR UNIT Air inlet Piping Air outlet (back and side) Drain hose Drain outlet ACCESSORIES 12 Drain socket Drain cap [ 33 1 2 MUZ-A18YV - E1 MUZ-A24YV - E1 MUZ-A26YV - E1 Single phase 230V,50Hz 20 7.38 0.30 SNB130FLDH 850 U-V 0.45 W-U 0.45 V-W 0.45 PM8H60-UB BLK-WHT 15...

Other Mitsubishi Models