Mitsubishi MCFH-A18WV- Installation Manual

Mitsubishi MCFH-A18WV

Mitsubishi MCFH-A18WV– Installation Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
Page: / 14

Table of Contents:

  • Page 2 – Caution; SELECTING THE INSTALLATION LOCATION; INDOOR UNIT
  • Page 4 – FLARED CONNECTIONS; PIPING PREPARATION; A CASE OF SUSPENDING INDOOR UNIT FROM THE CEILING; MOUNTING INSTALLATION PLATE FIXING BOLTS; INDOOR UNIT INSTALLATION; Determine the locations of installation plate fixing bolts.
  • Page 5 – FIXING OF INSTALLATION PLATES
  • Page 6 – A CASE OF INSTALLATING INDOOR UNIT ON THE WALL; Suspending unit from installation plate.; KNOCKOUT COVER
  • Page 7 – POWER SUPPLY AND CONNECTING WIRE SPECIFICATIONS; INDOOR AND OUTDOOR CONNECTING WIRE CONNECTION; REFRIGERANT PIPE WORK
  • Page 8 – DRAIN PIPE CONNECTION; In case of connecting drain pipe
  • Page 9 – OUTDOOR UNIT INSTALLATION
  • Page 10 – INDOOR/OUTDOOR UNIT CONNECTION FINISHING AND TEST RUN; Tools dedicated for the air conditioner with R410A refrigerant
  • Page 11 – PIPE CONNECTION; Indoor unit connection; Outdoor unit connection; PURGING PROCEDURES · LEAK TEST; PURGING PROCEDURES
  • Page 12 – PROCEDURE
  • Page 13 – FOR MOVEMENT AND MAINTENANCE; FRONT PANEL REMOVAL; GAS CHARGE; • Do not discharge the refrigerant into the atmosphere.
Loading the manual

INSTALLATION MANUAL

FOR INSTALLER

Floor and Ceiling Type Air-Conditioner

MCFH-A24WV

[FLARE CONNECTION TYPE]

HFC

utilized

R410A

CONTENTS

1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR

SAFETY ........................................................................................... 2

2. SELECTING THE INSTALLATION LOCATION ............................... 2

3. INSTALLATION DIAGRAM & ACCESSORIES ................................ 3

4. INDOOR UNIT INSTALLATION ....................................................... 4

5. OUTDOOR UNIT INSTALLATION ................................................... 9

6. INDOOR/OUTDOOR UNIT CONNECTION FINISHING AND

TEST RUN ..................................................................................... 10

7. FOR MOVEMENT AND MAINTENANCE ...................................... 13

English

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Caution; SELECTING THE INSTALLATION LOCATION; INDOOR UNIT

2 330 mm 360 mm 500 mm 840 mm 1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY ■ Do not install it by yourself (customer). Incomplete installation could cause injury due tofire, electric shock, the unit falling or leakage ofwater. Consult the dealer from whom you pur-chased the unit or special ...

Page 4 - FLARED CONNECTIONS; PIPING PREPARATION; A CASE OF SUSPENDING INDOOR UNIT FROM THE CEILING; MOUNTING INSTALLATION PLATE FIXING BOLTS; INDOOR UNIT INSTALLATION; Determine the locations of installation plate fixing bolts.

4 FLARED CONNECTIONS • This unit has flared connections on both indoor and outdoor sides.• Refrigerant pipes are used to connect the indoor and outdoor units as shown in the figure below.• Insulate both refrigerant and drain piping completely to prevent condensation. Limits Pipe length 25 m max. Hei...

Page 5 - FIXING OF INSTALLATION PLATES

5 4-1-(4) FRONT GRILLE REMOVAL • Remove front grille and transportation support. 4-1-(5) OPENING KNOCKOUT HOLE • Remove knockout holes with hammering it. 4-1-(6) FIXING UNIT TO INSTALLATION PLATES 1. Suspending unit from installation plates. • Hoist unit so that hanging bolt (4) on the sides of unit...