Mitsubishi MCF-24WV- User Manual

Mitsubishi MCF-24WV

Mitsubishi MCF-24WV– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
Page: / 52

Table of Contents:

  • Page 2 – INDOOR UNIT; Item
  • Page 3 – Air inlet; OUTDOOR UNIT; REMOTE CONTROLLER
  • Page 4 – SPECIFICATION; NOTE:Test conditions are based on ISO 5151
  • Page 5 – NOISE CRITERIA CURVES
  • Page 7 – OUTLINES AND DIMENSIONS; Service panel; REQUIRED SPACE
  • Page 9 – WIRING DIAGRAM; MV; NAME; MF
  • Page 11 – MC
  • Page 12 – REFRIGERANT SYSTEM DIAGRAM; Flared
  • Page 13 – Outdoor unit; Models
  • Page 14 – PERFORMANCE CURVES; Air flow should be set at MAX.; How to measure the indoor air wet-bulb temperature difference; Cover the thermometers to avoid direct rays of the sun.; SIDE VIEW
  • Page 15 – Dry Bulb temperature (; OUTDOOR LOW PRESSURE AND OUTDOOR UNIT CURRENT; COOL operation
  • Page 28 – MICROPROCESSOR CONTROL; WIRELESS REMOTE CONTROLLER; Example; INDOOR UNIT DISPLAY SECTION
  • Page 29 – Fuzzy control; — COOL mode of “I FEEL CONTROL” —; Indoor fan speed control
  • Page 30 – —DRY mode of “I FEEL CONTROL”—; Coil frost prevention
  • Page 31 – perature is 13°C or below.
  • Page 32 – How to set the timer
  • Page 33 – power button of the remote controller is off.; PROGRAM TIMER; The OFF timer and ON timer can be used in combination.; Operation indicator
  • Page 34 – SERVICE FUNCTIONS; unit operation; NOTE : For remodelling, take out the batteries
  • Page 35 – TROUBLESHOOTING; the components for bursting and discoloration.; Press the RESET button with tip end of ball point
  • Page 38 – Check of indoor fan motor; Indoor fan does not operate.
  • Page 40 – EMERGENCY OPERATION switch; Low High
  • Page 41 – DISASSEMBLY INSTRUCTIONS; OPERATING PROCEDURE; Removing the indoor fan motor; Photo 3
  • Page 42 – Photo 5
  • Page 43 – Screws for cabinet
  • Page 44 – Photo 6
  • Page 45 – Removing the electrical parts; Screws; Removing the cabinet
  • Page 46 – PHOTOS; Removing the outdoor fan motor
  • Page 47 – PARTS LIST; Part number that are circled is not shown in the illustration.; STRUCTURAL PARTS
  • Page 48 – Part numbers that are circled is not shown in the illustration.; ELECTRICAL PARTS
  • Page 52 – OPTIONAL PARTS; Copyright 2001 MITSUBISHI ELECTRIC ENGINEERING CO.,LTD; Standard interval for the filter replacement is about 1 year .
Loading the manual

SERVICE MANUAL

FLOOR AND CEILING TYPE AIR CONDITIONERS

CONTENTS

1. TECHNICAL CHANGES ····································2

2. PART NAMES AND FUNCTIONS ······················2

3. SPECIFICATION·················································4

4. NOISE CRITERIA CURVES ·······························5

5. OUTLINES AND DIMENSIONS ·························7

6. WIRING DIAGRAM ············································9

7. REFRIGERANT SYSTEM DIAGRAM ··············12

8. PERFORMANCE CURVES ······························14

9. MICROPROCESSOR CONTROL ····················28

10. SERVICE FUNCTIONS·····································34

11. TROUBLESHOOTING ······································35

12. DISASSEMBLY INSTRUCTIONS·····················41

13. PARTS LIST······················································47

14. OPTIONAL PARTS ······················BACK COVER

Wireless type
Models

MCF-13NV-

(WH)

·MUCF-13NV-

MCF-18NV-

(WH)

·MUCF-18NV-

MCF-24NV-

(WH)

·MUCF-24NV-

E3

E3

E3

E3

E4

E4

No. OB270

(When installed on the ceiling)

(When installed on the floor)

W

As for parts lists, all sub number’s series are included.

OB270--1.qxp 01.4.13 4:14 PM Page 1

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - INDOOR UNIT; Item

TECHNICAL CHANGES 2 1 PART NAMES AND FUNCTIONS INDOOR UNIT MCF-13NV - MCF-18NV - MCF-24NV - E3 E3 E4 (When installed on the floor) (When the air inlet grille is opened.) Deodorizing filter (gray sponge type)(option) Air filter Remote controller Air inlet Operation section Air cleaning filter (white ...

Page 3 - Air inlet; OUTDOOR UNIT; REMOTE CONTROLLER

MUCF-18NV - MUCF-24NV - E3 E3 Air inlet Air outlet Drain outlet Piping Drain hose OUTDOOR UNIT Air inlet Piping Drain hose Air outlet Drain outlet (back and side) OUTDOOR UNIT MUCF-13NV - E4 ON/OFF TOO COOL P M A M TOO WARM ON/OFF FAN TOO WARM TOO COOL VANE MODE STOP START HR. MIN. I FEEL COOL DRY P...

Page 4 - SPECIFICATION; NOTE:Test conditions are based on ISO 5151

4 SPECIFICATION 3 Indoor model Function Power supply Capacity Dehumidification Air flow(High) Power outlet Running current Power input Auxiliary heater Power factor Starting current Fan motor current Model Winding resistance(at20 : ) Dimensions W O H O D Weight Air direction Sound level (High) Fan s...

Other Mitsubishi Models