INDOOR UNITS
1 - 209
R410A Data
G6
LOSSNAY
LGH-RX
5
-E
1. DIMENSIONS
..............................
....................
.................................................................................................. 1 - 210
2. PERFORMANCES ............................................................................................................................................ 1 - 212
3. SPECIFICATIONS ............................................................................................................................................. 1 - 215
4. SAMPLE INSTALLATIONS ............................................................................................................................... 1 - 218
5. W IRING DIAGRAMS
............................
.......................
...................................................................................... 1 - 219
LOSSNAY is a perfect combination of heat recovery and ventilation, which is a leading edge product in the ventilation and air-conditioning field.
The LOSSNAY core is a special preserved paper made cross-flow and plate-fin structure, which is referable below.
Spacer plate
Partition plate
Fresh air induction
(fresh air)
Fresh air exhaust
(fresh heating/cooling air)
Stale air exhaust
(dirty indoor air)
Stale air induction
(dirty heating/cooling air)
Indoors
Outdoors
EA
SA
RA
OA
Stale hot air (exhaust)
Fresh cool air (outdoor)
0
˚C
(32
˚F
)
4
˚C
(39.2
˚F
)
20
˚C
(68
˚F
)
16
˚C
(60.8
˚F
)
Fresh warm air (indoor supply air)
Stale warm air (indoor air)
CITY MULTI can combine LOSSNAY into the air conditioning system, performing the best solution to ventilation and air-conditioning.
Line up of LOSSNAY units
Outdoor unit
Remote controller
Indoor unit
Indoor unit
Lossnay
LGH-15RX
5
[150m
3
/h Single phase 220-240V 50Hz]
LGH-25RX
5
[250m
3
/h Single phase 220-240V 50Hz]
LGH-35RX
5
[350m
3
/h Single phase 220-240V 50Hz]
LGH-50RX
5
[500m
3
/h Single phase 220-240V 50Hz]
LGH-65RX
5
[650m
3
/h Single phase 220-240V 50Hz]
LGH-80RX
5
[800m
3
/h Single phase 220-240V 50Hz]
LGH-100RX
5
[1000m
3
/h Single phase 220-240V 50Hz]
LGH-150RX
5
[1500m
3
/h Single phase 220-240V 50Hz]
LGH-200RX
5
[2000m
3
/h Single phase 220-240V 50Hz]
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
L o s s n a y INDOOR UNITS 1 - 210 R410A Data G6 1. DIMENSIONS LGH-15RX 5 -E LGH-35RX 5 -E LGH-65RX 5 -E LGH-50RX 5 -E LGH-80RX 5 -E LGH-25RX 5 -E 97.5 110 103 30 103 Position where duct direction Power supply SA (supply air) RA (return air) OA (outside air intake) (exhaust air outlet) EA (4-13x20 o...
L o s s n a y 4. SAMPLE INSTALLATIONS R410A Data G6 INDOOR UNITS 1 - 218 LGH-15RX 5 -E to 100RX 5 LGH-150RX 5 and 200RX 5 . Always lea v e inspection holes ( 450 or 600) on the air filter and LOSSNAY core remo v al side . . Always insulate the two ducts outside the room (intake air and exhaust air d...
L o s s n a y 5. WIRING DIAGRAMS R410A Data G6 INDOOR UNITS 1 - 219 Definition of Symbols r o t c e n n o C : 1 N C n a f t s u a h x e r o f r o t o M : 1 M (Transformer primary) r o t c e n n o C : 2 N C n a f y l p p u s r o f r o t o M : 2 M (Transformer secondary) r o t c e n n o C : 5 N C r o ...