Mitsubishi F940GOT-SWD-E- User Manual
Mitsubishi F940GOT-SWD-E– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Key to a Successful F900GOT Configuration
- Page 3 – Mitsubishi Electric Automation; Human Machine Interfaces 401; A. F900GOT Terminal Base Units; Communications Interface
- Page 4 – C. F900GOT Options and Accessories
- Page 5 – Human Machine Interfaces 403; F940GOT Supported CPU and Communication Drivers
- Page 6 – F900 Performance Specifications
- Page 7 – Human Machine Interfaces 405
- Page 8 – Human Machine Interfaces 406; Outline Dimensional Drawings
Mitsubishi Electric Automation
|
Human Machine Interfaces 399
F900GOT Family of Graphic Operator Terminals
The F900GOT Series of Graphical Operator Terminals is a complete line of compact, low cost, high performance interface panels ranging
from wide-display touch-screen to basic keypad models. F900GOT Family offers models with color or monochrome displays (STN & TFT),
2.6 to 7.0" screen size, and panel mount or handheld installation. F900GOTs support connection to Mitsubishi Electric sequence controllers,
several other controller brands, and to other products including motion controllers, barcode readers and printers. All models configure with
one easy to use software title.
Model Number
Description
Contents
Incl. with Product
JY992D86401
FX-10DM-E User's Manual
Introduction and Overview, Specifications, Installation
and Maintenance
Yes
JY997D02201
F920GOT-BBD5-K-E Installation Manual
Introduction and Overview
Specifications
Installation
Maintenance
Yes
JY992D95701
F930GOT Installation Manual
Yes
JY997D02501
F930GOT-BBD-K-E Installation Manual
Yes
JY992D94201
F940GOT Installation Manual
Yes
JY992D93901
F940WGOT Installation Manual
Yes
JY992D86901
F940 HANDY GOT Hardware Manual
Yes
JY992D99901
F940 HANDY GOT (RH model) Hardware Manual
Yes
JY992D94701
GOT-F900 Series Operation Manual
Introduction, General specifications
Operation, Features and Functions Descriptions
No (purchase
separately)
JY992D94801
GOT-F900 Series Graphic Operation Terminal Hardware Manual (connection)
Introduction and Overview, Installation and Connections
No (purchase
separately)
JY992D68301
FX-PCS-DU/WIN-E Operation Manual
Introduction and Installation and Requirements
Features and Functions Descriptions
Yes, with s/w title
SH(NA)080250
GT Works2/GT Designer2 Operating Manual
(Startup – Introductory Manual)
Basic Software Installation Information
Yes, with s/w title
SH(NA)080251
GT Works2/GT Designer2 Operating Manual
(Reference Manual)
Programming Manual — Detailed information/ instruction
for Objects, Features and Functions.
Yes, with s/w title
SH(NA)080278
GT Works2/GT Designer2 Operating Manual
Basic Software Information — understanding dialog box,
creating new projects
Yes, with s/w title
Manuals
F900GOT Hardware Features Include:
Compact design for today’s compressed panel and installation
space requirements
Ultra-wide viewing angles combined with crystal clear display
24VDC power supply (5VDC available in F920)
Embedded dual serial ports allowing flexible connection
methods without adding cost
Serial networking of terminals to a single target device
(up to 4 terminals)
Upgradeable OS
Programmable function keys (keypad models only)
IP65F environmental ratings
Class 1, Division 2, Group A, B, C and D environmental ratings
F900GOT Terminal Features:
Supports recipe management for easy manipulation
of complex data
Alarm management and messaging features
Supports time switching and scheduling of events
Supports trending and data sampling
Supports both local and global function operations
(keypad models only)
16 Levels of password protection (user and system levels)
Supports graphics, text and numerical data
Advanced F900GOT Maintenance Features:
(Supported by Mitsubishi FX Controllers only):
List Editor – Ability to read/write control logic of FX controllers
without a PC
Buffer Memory Monitor – Direct access to FX2N/2NC Special Function
Modules (SFM) and Buffer Memory (BFM) data locations
Controller Diagnostics – FX controller errors are displayed
Transparent Mode – Simultaneous serial communication of both HMI
and Mitsubishi controller from a PC (transparent mode is supported by
all Mitsubishi controllers)
Other embedded system menus and diagnostics – access to advanced
maintenance screens that require no user program development
(available only for Mitsubishi controllers)
F900GOT Pendant Terminal Features:
Hard wired redundant or single contact e-stop and function
keys available
Programmable 3 position grip switch or operator grip switch available
Programmable LEDs
Built-in communication interface
IP54F environmental rating
Class 1, Division 2, Group A, B, C and D environmental ratings
J_385_416 3/16/07 6:46 PM Page 399
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
400 HUMAN MACHINE INTERF ACES A C B B D A B C B D Cable made by user 3rd Party Manufacturer PULL USB Q25HCPU QX10 QJ71BR11 RUN T.PASS SD ERR MNGD.LINKRDERR RUN T.PASS SD ERR MNGD.LINKRDERR QX41 0123456789ABCDEF MODE RUN ERR USER BAT BOOT PULL QJ71BR11 QX41 POWER Q61P-A1 PULL USB Q25HCPU QX10 QJ71BR1...
Mitsubishi Electric Automation | Human Machine Interfaces 401 HUMAN MACHINE INTERF ACES Product Model Number Compliance Specifications Stk Item Text Terminal FX-10DM-E UL • cUL 2 line, 16 character backlit LCD display, 5 VDC powered S F920GOT F920GOT-BBD5-K-E CE • UL cUL 128 x 64 LCD display, 2 colo...
402 HUMAN MACHINE INTERF ACES Product Model Number Specification Stk Item Screen Data F9GT-40FMB Flash cassette (1 Mbytes) for transferring screen data to/from FGOT (F94 (W) only) S Transfer Board F9GT-40UMB Board for transferring user created screen data to / from the GOT to EPROM (F94 only) – EPRO...