Page 2 - End User Software License agreement; to change without notice to User.
2/94 End User Software License agreement Mitsubishi Electric Corporation and the third party as original development company reserve all the intellectual property rights to this Software for DX-PC200 (“Software”) and its associated operation manual (“Operation Manual”). Mitsubishi Electric Corporati...
Page 3 - Contents
3/94 Contents 1 Introduction ................................................................................................................................................................................ 7 1.1 Features ..................................................................................
Page 6 - agreement of Kakadu Software.
6/94 6.3.9. Calling layouts of camera windows that display copied data <Grouping function> ............. 89 6.3.10. Option settings .............................................................................................................................................. 90 6.3.11 Convertin...
Page 7 - Introduction; DVR status; System requirements
7/94 1 Introduction DX-PC200 is application software to replay video data recorded by Mitsubishi’s digital recorder on Windows 2000 or Windows XP. In combination with DVR series having network function, you can set and operate the recorder and load recorded images and the latest live image from the ...
Page 8 - Compatible digital recorders; Notice
8/94 used.) • NIC that operates correctly under the condition satisfying the above-mentioned requirements (Necessary when the network function is used.) Notice • Operation of this software is not always guaranteed in any environment that satisfies the above-mentioned system requirements. 1.3 Compati...
Page 9 - Setup
9/94 2 Setup 2.1 Setup (Installation) To install this software, start the Setup Launch.exe file contained in the DX-PC200 folder of this CD. Follow the instructions displayed on the screen, and the setup will automatically start. The default setup location is C: ¥Program Files¥DXPC200. Before instal...
Page 10 - Three main screens; screen enables remote monitoring of various scenes.
10/94 3 . Three main screens The DX-PC200 has three main function screens. Switch these screens as required. Each screen enables remote monitoring of various scenes. Main View screen Single View screen Multi View screen
Page 12 - If it is not necessary to log in, click the
12/94 If it is not necessary to log in, click the button. When a first user name is entered, the message shown in the following figure will appear. Click [Yes] to register the manager entered user name in the DX-PC200. Notice You can log in the DX-PC200 without entering the user name and the passwor...
Page 14 - registration are overwritten.
14/94 3.2.1 Screen selector buttons At the upper center of the Main View screen, there are three screen selector buttons. Use these buttons to go to the desired screen. On the Single View screen and the Multi View screen, these buttons are also displayed at the same position. 3.2.2 Recorder list con...
Page 15 - Recorder operation buttons
15/94 3.2.3 Recorder operation buttons At the lower center of the Main View screen, there are recorder operation buttons. Use these buttons to operate each recorder. Starting from the left, the Search button, Recorder Control button, Data Manager button, Recorder Settings button, and System Log List...
Page 16 - System Log List button; Filter Settings button; set various filters.
16/94 • System Log List button When you want to look through the logged data of a recorder stored in the system log list, select the recorder from the list, and then click this button. The System Log List panel will be opened. For a detailed description of the system log list, refer to Sec. 4.6. 3.2...
Page 17 - Options button; Filtering
17/94 3.2.5 Options button The Options button is at the lower section of the Main View screen. Use this button to display the Options panel. Using the Options panel, you can set the detailed operations of the DX-PC200. For a detailed description of options, refer to Sec. 4.7. Filtering To use the fi...
Page 18 - Recorder list
18/94 3.2.6 Recorder list The connection status, operation status, etc. of each recorder are displayed on the recorder list. There are radio buttons at the lower right section of the list. Use these radio buttons to enable or disable the filter function. For a detailed description of the filter func...
Page 19 - Event list
19/94 3.2.7 Event list The DX-PC200 receives the IP issued events sent from the recorders to display the event list (refer to Sec 5.9). When the DX-PC200 receives an event, the bell displayed under the list will sound. Click the bell to stop sounding the bell. On the Single View and Multi View scree...
Page 20 - Connect button and Disconnect button; Connect button
20/94 3.2.8 Connect button and Disconnect button Use these buttons to connect or disconnect each recorder to the DX-PC200. The Connect/Disconnect panel will appear. When the Connect button is pressed, the DX-PC200 will select disconnected recorders from all the registered recorders to display the di...
Page 21 - button on the right side of the list to disconnect the recorder.
21/94 To display the newly connected recorder, refer to Sec. 5.3.4. When the Disconnect button is pressed, the DX-PC200 will select connected recorders from all the registered recorders to display the connected recorders only. From the displayed list of connected recorders, select a recorder you wan...
Page 23 - Camera window
23/94 Camera Window Panel button (Sec. 3.3.2): Displays the Camera Window panel. Scene Capture button (Sec. 4.10.2): Stores the currently displayed image in the specified place. Recent Play button (Sec. 4.10.3): Displays the last scene you have seen just now. NET Alarm Input button (Sec. 4.10.4): Se...
Page 24 - Camera Window panel
24/94 Next Page button 3.3.2 Camera Window panel On the right side of the Camera window, click the Camera Window Panel button to display the Camera Window panel. If the Camera Window Panel button is not displayed due to the optional setting, click the image display area of the Camera window to displ...
Page 26 - Camera list
26/94 Group name: Use the dropdown menu to switch the group name. 3.3.3 Camera list On the camera list, the statuses of the currently displayed cameras are displayed. For the camera list, there are two display modes: the “all cameras” display mode and the “grouping” display mode. Use the radio butto...
Page 27 - Screen layout buttons
27/94 User grouping button Specified grouping button Patrol setting/start button User grouping setting button 3.3.4 Screen layout buttons Use the grouping function to store all the screen layout data, such as the displayed camera position data and the camera size data, at a time. Display the desired...
Page 28 - Obtained data control area; speed will reduce the image quality.; DVR selector button; execute button on the right.
28/94 3.3.5 Obtained data control area In this area, there are buttons that can control the images and sounds sent from the recorders. On the left side, there are slide bars and the list box that can display the dropdown menu. Use one of the slide bars to determine the image updating speed, and use ...
Page 31 - Various function screens
31/94 Detailed Information button OK button User ID box Password box 4 . Various function screens 4.1. Register/Edit Recorder panel Use this panel to register recorders in the DX-PC200 or to edit the recorder data. At the lower left section of the Main View screen, click the Edit Recorder List butto...
Page 34 - Time Search tab
34/94 Execute Searching button 4.2.1 Time Search tab Use this tab to search the recorder images for the specified date and time. Using the slide bar displayed at the lower section, roughly specify the date and time. After that, using the dropdown menu and the spin control function, specify the detai...
Page 35 - Alarm List Search tab; Click the Update button
35/94 4.2.2 Alarm List Search tab Use this tab to search the alarm list for the desired alarm image of the recorder. Click the Update button to obtain the latest alarm list from the recorder. Some recorders enable specification of the list obtainment range, camera channel, total number of alarms to ...
Page 37 - Bookmark Search tab; from the list using the bookmark.
37/94 4.2.3 Bookmark Search tab When a regenerated recorder image is being displayed, a bookmark can be attached to the image (refer to Sec. 5.6.1). If a bookmark is attached, the image can be easily searched out from the list using the bookmark. Select a bookmark from the list, and then click the S...
Page 38 - Protected Data Search tab
38/94 4.2.4 Protected Data Search tab Use this tab to obtain data from the recorder equipped with the data protective function. Click the Update button to obtain the protected data list from the recorder, and then specify the desired record area. After that, click the Search button to carry out sear...
Page 42 - Obtainment of specified file and registration of set data; start recording operation again.; Following items are set in a unique way to DX-PC200.
42/94 4.4.1. Obtainment of specified file and registration of set data Click the Read button in the Recorder area to obtain the previously set menu data from the connected recorder. After editing the obtained data, click the Register button in the Recorder area to register the set menu data in the r...
Page 44 - maximum number of characters.
44/94 Notice If the registration operation is performed with full-size characters for the item (POP server, SMTP server, etc.) where the use of 2 byte code characters is prohibited on the recorder side, abnormality may occur in the subsequent related operation. If such an abnormality takes place, yo...
Page 46 - General; “Control description”:
46/94 4.7. Options panel Click the Options button on the Main View screen. The Options panel will be opened. On the Options panel, select an item from the dropdown menu at the top of the screen, and then set or change the operation data on the application software. 4.7.1 General “Language setting”: ...
Page 49 - Camera Window; “Information setting”:
49/94 4.7.3 Camera Window “Control setting”: Enter a check in the check box of each button to display the button on the right side of the Camera window. If it is not necessary to display a button, delete the check from the check box. After entering/deleting a check in/from the check box of a button,...
Page 50 - Scene Capture; during the scene capture operation.; “Do you want to overwrite the data?” will not appear.
50/94 4.7.4 Scene Capture “Folder path”: Set a folder name in this box. The image data will be stored in the set folder during the scene capture operation. “File Name”: Set a file name in these boxes. The image data will be stored in the set files during the scene capture operation. “File format”: S...
Page 51 - DB Maintenance; Event retention period
51/94 4.7.5 DB Maintenance “ Event retention period “ Click the checkbox and then set how many days the data base of the event list is maintained.
Page 52 - Schedule List tab
52/94 Downloading schedule list Add Download Data button Refer to Sec.4.8.3. Edit Download Data button Filtering Delete Download Data button 4.8. Data Manager panel Click the Data Manager button at the lower section of the Main View or Single View screen. The Data Manager panel will appear. Using th...
Page 53 - Data List tab
53/94 Copy data list Import Data button Export Data button DataViewer button Filtering Delete Copy Data button 4.8.2 Data List tab
Page 54 - Section Download panel
54/94 4.8.3 Section Download panel Click the Add/Edit Download Data button at the lower section of the Schedule List screen of the data manager (refer to Sec. 4.8.1). The Section Download screen shown below will appear. Set the following items in areas ① through ⑩ : Area ① : Set the download start t...
Page 55 - condition. Therefore, the section download isn
55/94 Notice In the data downloaded by this function, frame loss may occur depending on the communication condition. Therefore, the section download isn ’ t recommended for backup use. To download a large amount of data from the recorder for a long period, it is recommended to use the copy function ...
Page 57 - Call of registered Grouping; There are 3 methods to make a call of the Grouping.
57/94 4.9.2 Call of registered Grouping There are 3 methods to make a call of the Grouping. When a call of the Grouping is made, the dropdown section of the camera list and the display of the camera list are changed simultaneously. 1. Call from camera list Select a desired Grouping in the Dropdown s...
Page 58 - Sequential display in stored screen layout ; Click the trash bin button in the right section of the panel to
58/94 4.9.3 Sequential display in stored screen layout <Patrol function> With a click on the patrol/monitor button below the camera list, you can patrol/monitor the registered Groupings at a specific time intervals. During patrolling/monitoring, the button arrows are animated as if they revolv...
Page 59 - Allocating Groupings to Grouping buttons; list, select a Grouping which you want to allocate to that button.
59/94 4.9.4 Allocating Groupings to Grouping buttons Groupings can be allocated to the 8 numeric buttons below the camera list by users. With a click on the user button to which Grouping is not yet allocated, the “Grouping Select” dialog opens. As Groupings which have already been registered are dis...
Page 60 - Various operations on Camera window; move it to an easily viewable position.; Capturing the currently displayed image ; button at the right of the window.; Viewing preceding recorded images
60/94 4.10 Various operations on Camera window 4.10.1. Facilitating visibility of the Camera window <Gaze window function> When the Camera window is small and is displayed on the edge of the PC screen, you can move it to an easily viewable position. With a click on the button in the upper sect...
Page 62 - alarm-recorded during live image viewing.; Controlling the PTZ camera ; Column to display information
62/94 4.10.4. Starting alarm recording manually <NET alarm recording function> You can start alarm recording by clicking the button if you find an important scene to be alarm-recorded during live image viewing. In this case, the alarm recording duration set in the recorder is applied. You can ...
Page 65 - with printer drivers not supporting multiple copy printing.
65/94 4.10.7 Printing out with a printer With a click on the button of the Camera window, the Print window below opens. By pressing the print button at the lower right, you can print using the printer. ● [Preview]・・・・・・Print preview is displayed. ● [Margins]・・・・・・・・・・・Enter margins in millimeters. ●...
Page 66 - Operation via network; network function by reading this chapter from the beginning.; Connecting hardware; an example of simple connection.; When connecting one PC and one recorder using a cross cable (LAN):
66/94 5. Operation via network In this chapter, the network function of the DX-PC200 is explained from a usage point of view. Even if you are using the DX-PC200 for the first time, you will get to learn the full scope of the network function by reading this chapter from the beginning. 5.1 Connecting...
Page 67 - Setting for communication between the recorder and PC; Setting the IP address of the recorder; Internet
67/94 5.1.3. When connecting one PC and more than on recorder using an ADSL router (via the Internet): 5.2. Setting for communication between the recorder and PC Following settings are required for communication between the recorder and PC. This section describes an example of networking using a swi...
Page 68 - Setting the port number of the recorder; shown by [USER ACCESS] port of the recorder is 53705. You don; Setting the IP address of the PC; ADSL routers don
68/94 5.2.2 . Setting the port number of the recorder For communication between the recorders and PC, it is required to set a port number. You can find this port number by [USER ACCESS] port in the Network menu of the recorder. The default port number shown by [USER ACCESS] port of the recorder is 5...
Page 70 - Viewing LIVE after registering the recorder; Registering the recorder; When
70/94 5.3. Viewing LIVE after registering the recorder On completion of physical connection and setting of the recorder, PC, and the recorder, register the recorder which you want to connect to the DX-PC200. For the registration, information regarding the IP address of the recorder which you want to...
Page 71 - Connecting network to an arbitrary recorder; are registered in the recorder and click the OK button.
71/94 5.3.2 Connecting network to an arbitrary recorder In order to connect to an arbitrary recorder, select a desired recorder from the recorder list (refer to Sec. 3.2.6) on the MainView screen and attach a check to the Connection Check Box. As the Recorder Login dialog (figure below) is displayed...
Page 72 - Changing display to the SingleView (MultiView) screen; renewal of the live images of 4 screens starts automatically.; Changing the screen layout; As for the DX-PC200, 7 types of basic layouts are available. When the
72/94 5.3.3 Changing display to the SingleView (MultiView) screen With a click on the selector button of the SingleView screen of the MainView screen, go to the SingleView screen or the MultiView screen. When the screen goes to the SingleView screen, renewal of the live images of 4 screens starts au...
Page 73 - Changing the displayed camera; by setting the camera list to the All Camera display mode.; recorded at a low picture quality level.
73/94 5.3.5 Changing the displayed camera In order to change the camera image displayed in an individual Camera window, drag a desired camera from the camera list at the right of the screen and drop it in the Camera window where you want to change the display camera. Not only you can change the disp...
Page 74 - reduce the refresh speed.; Starting the live operation with other method; view on the SingleView screen.
74/94 When the recorder’s communication operation is unstable or the network band is insecure, reduce the refresh speed. When a PC to be used does not have sufficient processing power, reduce the refresh speed. 5.3.6 Starting the live operation with other method In addition to the procedures mention...
Page 75 - What you can do during the live monitoring operation; monitoring operation.; Listening to live sound; deploying to the right, the same sound control is provided in the 3
75/94 5.5. What you can do during the live monitoring operation The following functions can make live monitoring more effective when used during the live monitoring operation. ・ Scene capture (Sec. 4.10.2) ・ Recent play (Sec. 4.10.3) ・ NET alarm record (Sec. 4.10.4) ・ PTZ (Sec. 4.10.5) ・ MODEOUT (Se...
Page 76 - s capacity may affect loading of
76/94 Notice When band control is being applied to the recorder, ample communication band is not secured, or internal processing with heavy load (such as recording, copying, motion detection by the recorder) is underway, it may be impossible to load clear live audio. Further, the PC ’ s capacity may...
Page 77 - Registering a book mark; recorder and these marks are stored after the DX-PC200 is closed.
77/94 5.6. Searching for a desired image from the image data stored in a recorder Vast amounts of image data are recorded in the recorder. Use the following methods to search for the desired data. ・ Search by time (Sec. 4.2.1) This serves to search for the desired image by date and time. Search thro...
Page 78 - Storing images obtained from a recorder in a PC and printing
78/94 5.7. Storing images obtained from a recorder in a PC and printing <How to store> With a click on the Scene Capture button adjacent to the Camera window, the image displayed there is stored in the PC. The image data is stored in the cap_img folder in the MyDocuments as default. The name o...
Page 80 - Receiving IP AlarmNotify of the recorder; Setting IP AlarmNotify of the recorder
80/94 5.9. Receiving IP AlarmNotify of the recorder With the DX-PC200, you can be notified of occurrences of events on the PC by utilizing IP AlarmNotify from the recorder. In addition, you can confirm the event on a displayed list and search for the recorder image at the corresponding time as requi...
Page 81 - acknowledgment to users (Display on the PC screen and alarm sound).
81/94 The DataManager screen is displayed and at the same time residing in the task tray starts. Even if the DataManager screen is closed with the x button in this state, residing in the task tray is not released. This panel serves to segmentalize the contents notified from the recorder and acknowle...
Page 82 - Receiving IP AlarmNotify; The massage with a button below is displayed near the task tray.
82/94 5.9.3 Receiving IP AlarmNotify When an event worthy of notification occurs on the recorder and IP AlarmNotify is sent to the PC installed with the DX-PC200, two types of information are informed according to current status of the PC. <When DX-PC200 is not active> The massage with a butto...
Page 83 - Confirming the recorder image at the time of AlarmNotify event; displayed when no recorder image exists for the event.; Adjusting the event list display (Filtering)
83/94 Filter OFF Filter ON 5.9.4 Confirming the recorder image at the time of AlarmNotify event With a double-click on the item line of the event list, you can call the recorder image of the recorder at the time when that event has happened. When the Time Search panel in which event time has been se...
Page 84 - Playing back the copy data; Placing copy data under control of DataManager
84/94 6. Playing back the copy data The DX-PC200 can play back, by using the designated viewer, data which are directly copied to a copy media such as a DVD-R and USB memory, or data which are copied from a recorder through network by section-downloading. 6.1 Placing copy data under control of DataM...
Page 85 - Playing back copy data
85/94 6.2 Playing back copy data Selecting, from the list, the copy data which you want to play back with the data list tab of DataManager, click the Data Playback button. The viewer software for data playback starts up and stands by in the status where the data is read. After that, only with the Pl...
Page 86 - Playing back audio data; 【Not Synchro. playback】; • The settings on this panel remain intact for the next startup.
86/94 6.3.1 Playing back audio data You can play back audio data contained in the copied data using the following procedure. 【Not Synchro. playback】 Put a checkmark to [Output] on the FSMPlayer panel and select a playback channel from the drop-down menu. Then select [Not Synchro.] in the [Playback] ...
Page 88 - Searching for an image
88/94 6.3.5. Displaying the recording date and alarm on the copied data playback window To select items you want to display on the window, use the [Title Bar] command in the [View] menu. 6.3.6. Searching for an image Click [Search...] in the [Search] menu on the FSMPlayer window. The following searc...
Page 90 - Option settings; You can set following three options using this box.
90/94 When you click the buttons on the right of the pattern buttons, the grouping setting dialog box appears. Using this dialog box, you can change the cameras displayed on respective windows. Click a window position to select a camera you want to display in that position. 6.3.10. Option settings C...
Page 91 - Converting the format of the copied video data collectively;
91/94 6.3.11 Converting the format of the copied video data collectively You can convert the formats of the copied video data into general formats such as JPEG and AVI collectively. Click [Convert] in the [File] menu of FSMPlayer. Specify the range of data you want to convert collectively by date an...
Page 93 - Appendix
93/94 7. Appendix 7.1 Restrictions • • Functions supported by this software depend on the type of your Mitsubishi digital recorder. For models supported by this software, refer to the section of “ Compatible digital recorders ” in this manual. • • If an operation problem should occur and you can ’ t...