Meyer Sound galileo 616 - Manual

Meyer Sound galileo 616

Meyer Sound galileo 616 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
57 Page 57
58 Page 58
59 Page 59
60 Page 60
61 Page 61
62 Page 62
63 Page 63
64 Page 64
65 Page 65
66 Page 66
67 Page 67
68 Page 68
69 Page 69
70 Page 70
71 Page 71
72 Page 72
73 Page 73
74 Page 74
75 Page 75
76 Page 76
77 Page 77
78 Page 78
79 Page 79
80 Page 80
81 Page 81
82 Page 82
83 Page 83
84 Page 84
85 Page 85
86 Page 86
87 Page 87
88 Page 88
89 Page 89
90 Page 90
91 Page 91
92 Page 92
93 Page 93
94 Page 94
95 Page 95
96 Page 96
97 Page 97
98 Page 98
99 Page 99
100 Page 100
101 Page 101
102 Page 102
103 Page 103
104 Page 104
105 Page 105
106 Page 106
107 Page 107
108 Page 108
109 Page 109
110 Page 110
111 Page 111
112 Page 112
113 Page 113
114 Page 114
115 Page 115
116 Page 116
117 Page 117
118 Page 118
119 Page 119
120 Page 120
121 Page 121
122 Page 122
123 Page 123
124 Page 124
125 Page 125
126 Page 126
127 Page 127
128 Page 128
129 Page 129
130 Page 130
131 Page 131
132 Page 132
133 Page 133
134 Page 134
135 Page 135
136 Page 136
137 Page 137
138 Page 138
139 Page 139
140 Page 140
141 Page 141
142 Page 142
143 Page 143
144 Page 144
145 Page 145
146 Page 146
147 Page 147
148 Page 148
149 Page 149
150 Page 150
151 Page 151
152 Page 152
153 Page 153
154 Page 154
155 Page 155
156 Page 156
157 Page 157
158 Page 158
159 Page 159
160 Page 160
161 Page 161
162 Page 162
163 Page 163
164 Page 164
165 Page 165
166 Page 166
167 Page 167
168 Page 168
169 Page 169
170 Page 170
171 Page 171
172 Page 172
173 Page 173
174 Page 174
175 Page 175
176 Page 176
177 Page 177
178 Page 178
179 Page 179
180 Page 180
Page: / 180

Table of Contents:

  • Page 3 – TABLE OF CONTENTS
  • Page 5 – List of Figures
  • Page 7 – List of Tables
  • Page 9 – PREFACE : DOCUMENTATION OVERVIEW; About this Document; Compass; Audience
  • Page 10 – Organization; This manual comprises the following chapters:; Related Documentation
  • Page 14 – Strong emphasis; Data to be typed; Control Label; Filename
  • Page 16 – About Meyer Sound; COMPASS; With all the features and power offered by Galileo
  • Page 17 – You may also contact us directly:; Technical Support; Web Site Support
  • Page 18 – Before Using Technical Support; A precise description of the problem.
  • Page 19 – CHAPTER 1: START HERE; System Requirements; Mac OS X
  • Page 20 – Installing Compass and Virtual Galileo; Microsoft Windows
  • Page 21 – Running Compass with Virtual Galileo
  • Page 22 – Using the Built-In Virtual Galileo for Stand-alone Development; Select the Galileos tab.
  • Page 23 – Using the Stand-Alone Virtual Galileo
  • Page 24 – Running Compass with Galileo; Network Connections; Auto-discovery Connection of Galileo 616 Units
  • Page 27 – CHAPTER 2: COMPASS OVERVIEW; Compass Capabilities
  • Page 28 – Compass Controls; The following sections discuss the major controls in more detail:; Using Tabs
  • Page 29 – Using Value Boxes
  • Page 31 – Using Encoders
  • Page 32 – Using Faders; label will set the gain to full attenuation. As well, clicking above; Using Meters
  • Page 34 – General Workflow; The following steps outline a typical Compass workflow.
  • Page 37 – Atmospheric Correction and Array Correction
  • Page 41 – CHAPTER 3: USING COMPASS TOOLS; Navigating the Tabbed Window Interface; ms.” Finally, where instructions reference a; Windows Keyboard
  • Page 42 – Using Shortcuts; When using the mouse, hold ‹ Cmd › when dragging or clicking a control.
  • Page 44 – Setting Compass and Channel Preferences
  • Page 46 – Configuring Audio Inputs and Outputs
  • Page 47 – Configuring the Galileo 616 for Analog Audio Input; Select the appropriate Input Voltage Range for the input source.; Configuring the Galileo 616 for Digital Audio Input
  • Page 48 – Configuring Many Galileos Simultaneously; On the Galileos page:; Configure the Galileos as described in the previous procedures.; Using the Summing Matrix; Using the Summing Matrix as a Signal Router; Select Router Mode, located at the top left of the page.
  • Page 49 – Creating a Custom Summing Matrix; Clear Router Mode, located at the top left of the page.; Resetting Matrix Values
  • Page 56 – x8.galileoSummingMatrix
  • Page 58 – Diagonal.galileoSummingMatrix
  • Page 59 – All Off.galileoSummingMatrix
  • Page 60 – Linking Channels; Linking Arbitrary Channels via Select
  • Page 61 – Set Isolate Linking Behavior:
  • Page 62 – Quickly See Which Channels Are Linked
  • Page 63 – Set Gain Control Linking Mode:
  • Page 64 – Linking Galileos; Linking Galileo Units
  • Page 65 – Atmospheric Correction and M Series Array Correction; Atmospheric Correction
  • Page 66 – Setting Environment Conditions for a Single Galileo Unit; Select the Galileo Map page for the Galileo.; Setting Loudspeaker Distance for a Single Channel
  • Page 68 – M Series Line Array Correction; Configuring M Series Array Correction
  • Page 69 – Set TruShaping to LD-2 Array.galileoTruShapingEq; Connecting and Configuring for use with SIM3
  • Page 70 – Configuring Galileo for SIM3; Select a SIM3 Trim mode:
  • Page 71 – Using Signal Processing; When working with multiple EQ plots:; Enable the Settings control, located in the top right corner.; Maximizing the EQ Plot Area
  • Page 72 – Clear the Dual View setting.; Screen-splitting the Processing Window; Enable the Dual View control, located in the top right corner.; Displaying Multiple EQ Plots
  • Page 73 – Parametric EQ; Hold ‹ Alt › while dragging to adjust the bandwidth/gain plane.
  • Page 74 – TruShaping EQ; Drag a horizontal handle to adjust gain.; Type values in the Gain and Freq boxes.
  • Page 75 – Graphic EQ; Type a value in the Gain box.
  • Page 76 – Subwoofer Filtering; Using Low Pass Filtering; In the selection box beside the Freq control, select Low Pass.; Using High Pass Filtering; In the selection box beside the Freq control, select:; Delay; Up to two seconds of delay may be applied to inputs and outputs.
  • Page 77 – Setting Input Channel Delay
  • Page 78 – Copy/Reset an Individual Channel Control Value; Copy/Reset Summing Matrix Control Values; Save and Load file names have the form; or; Save and Load file names have the form; dependent on the choice you make.
  • Page 79 – Copy/Reset All Control Values of an Input or Output Channel; Right-click the Input Masters or Output Master page tab.; and; Copy/Reset All Control Values of Galileo System Settings; Copy/Reset All Control Values of an Galileo Unit; Saving and Loading Projects and Snapshots
  • Page 80 – Snapshots; Creating a Snapshot; Click Create. The Create New Snapshot window will be displayed.; Recalling a Snapshot; From the Snapshot Library, select the desired snapshot.
  • Page 81 – Locking a Snapshot
  • Page 82 – Saving a Snapshot; Loading a Snapshot; In the button row below the library list, click Load....; The loaded snapshots are added to the library list.
  • Page 83 – Using Snapshots for Tour Setup; Projects; Creating a New Project; In the Current Project box, click Save As....; Saving a Project
  • Page 84 – An extra set of controls will now be shown.; In the Current Project box, click More
  • Page 86 – Restricting Access to Compass Settings; Locking Galileo Controls; Click Change Access Code to lock-down the Galileo unit.; Unlocking Galileo Controls; Changing Galileo Access Control; In the Access Code boxes, type the previously-assigned access code.
  • Page 87 – Click Change Access Code to lock-down the Galileo unit again.; Removing Galileo Access Control; Recovering a Lost Access Password
  • Page 89 – CHAPTER 4: USER INTERFACE REFERENCE; Compass Tab; Compass Preferences
  • Page 91 – Recommended Scale; Plotter Control Handle Scale; Value Controller Type; Encoder; Input Device Type; Mouse
  • Page 92 – loading or saving files during a performance.
  • Page 93 – Show Meter Values; Startup Galileo Discovery and Connection Options:; Find available Galileos on startup; Sets the measurement unit for delay values.; Equalization Bypass on System Map is read-only
  • Page 94 – Clip Indicator Clear Mode; Channel Linking Preferences; Help; Displays contextual help for this page.
  • Page 95 – Gain Control Linking Mode:
  • Page 96 – Isolate Linking Behavior:; All selected channels on selected Galileos are globally linked
  • Page 99 – Isolated channels have two possible behaviours, described below.
  • Page 101 – Isolated channels have two possible behaviors:; Enable global linking of isolated channels
  • Page 102 – Disable global linking of isolated channels; Galileo; System Settings - Enable Linking Across Selected Galileos:
  • Page 104 – Galileos Tab; Galileo 616 List Control:; Find Galileos; Updates the status of the listed Galileos.
  • Page 106 – projects have; .galileoGlobalProject; appended to the file name.; Project
  • Page 107 – Disconnected Galileos do not participate in global saves.; Include in Global Project; Selects Galileos for inclusion in the global project file.; Save Individual Project Files; form; Retrieve Projects
  • Page 108 – Shows information about connected Galileo units.
  • Page 110 – Select Connect to connect to the Galileo.
  • Page 111 – Select Show to restore the Galileo tab at the top of the window.; Global Atmospheric Correction Control:; Temperature; Sets the facility temperature.; Humidity; Sets the facility humidity.; Altitude; Sets the facility altitude.; Named Galileo Tabs; Status Bar
  • Page 114 – Shows information about the currently active snapshot.; Not Modified / Modified
  • Page 115 – Shows information about the current project.; Modified
  • Page 116 – Displays or hides additional project controls:; Notes; Saves a duplicate of the project file to; Open; When connected to live amplified loudspeakers, loading Galileo
  • Page 118 – Removes the selected, unlocked snapshot from the library.
  • Page 119 – Paste; into the current library. Snapshot file names have the form; Settings
  • Page 120 – Network; Galileo Device Type, Galileo Device Nickname, IP Address; Firmware file names have the form
  • Page 121 – Input and Output
  • Page 122 – Enable Linking Across Selected Galileos; Output Voltage Range:
  • Page 124 – SIM3 Trim Disabled / SIM3 Trim Enabled; SIM3 Output Probe Point; Output Post Delay
  • Page 125 – Environment; Sets the humidity for the venue.
  • Page 126 – Sets the altitude range for the venue.; Atmospheric Correction Distance Linked; Access
  • Page 127 – Displays the status of this page.
  • Page 128 – Array Correction; Displays the name of this type of array. You may type a new name.
  • Page 129 – Status; Enables or disables loudspeaker array correction.; Type; Selects the type of Meyer Sound M Series loudspeaker array.; Size; Selects the number of loudspeaker units in the array.; Array Correction Output Assignments
  • Page 130 – Link Groups; Link Group Input Assignments:; Group Name; Displays the name of the link group. You may type a new name.
  • Page 131 – Enables and disables the link group.
  • Page 132 – Galileo Map; Select
  • Page 133 – Displays the channel label. You may type a new label.; Displays the appropriate Input Processing page.
  • Page 134 – Selects the signal polarity.
  • Page 136 – Closes the Galileo Map Control window.; Displays context help for this window.
  • Page 137 – Atmospheric Correction:; Sets the altitude for the venue.
  • Page 138 – Input Processing; Located along the top of the window, below the tab bar.
  • Page 141 – Handles
  • Page 143 – Channel Settings
  • Page 144 – Parametric; Parametric Enabled / Parametric Bypassed
  • Page 145 – TruShaping; TruShaping Enabled / TruShaping Disabled; Enables or bypasses TruShaping EQ.; Equalization Enabled / Equalization Bypassed; Enables or bypasses all EQ.; Gain; Sets the gain value for a TruShaping EQ band.; Freq; Sets the frequency value for a TruShaping EQ band.
  • Page 146 – Graphic EQ Enabled / Graphic EQ Bypassed; Enables or bypasses graphic EQ.; Sets the frequency value for a graphic EQ band.; Sets the gain value for a graphic EQ band.
  • Page 147 – Output Processing; Output Channel; Selects the output channel by channel label.
  • Page 149 – Label; Displays the channel label. You may rename the channel.; Sets the channel gain value.
  • Page 150 – Displays the Array Correction settings page.
  • Page 153 – Summing Matrix; Router Mode; Toggles the matrix crosspoints between switches and knobs.
  • Page 154 – Input Masters; Channel Label; Processing Shortcut
  • Page 155 – Adjusts the input signal level.; Mute
  • Page 156 – Output Masters
  • Page 157 – Additional User Interface Details; Setting
  • Page 158 – Displays contextual help.; Cancel
  • Page 159 – Keyboard Modifiers and Shortcuts; Action; Colors
  • Page 160 – Tab Colors; Background Colors; Meaning
  • Page 161 – Channel Colors
  • Page 163 – APPENDIX A: COMPASS SOFTWARE FILE LOCATIONS; Table A.1. OS X Compass Software Installation Locations; Project Backups; Backup file names take the form
  • Page 164 – Factory Presets; Matrix controls. The presets files are located in the
  • Page 165 – APPENDIX B: NETWORK INFORMATION; Virtual Galileo
  • Page 167 – High-Frequency Equalization Strategies; frequencies need less correction in this zone.
  • Page 168 – Low-Frequency Equalization Strategies; Directionality decreases.
  • Page 169 – Example Curves; Simple Flat Response Curve
  • Page 171 – High-Frequency Response Curves
  • Page 172 – Low-Frequency Response Curves
  • Page 173 – Combined Response Curves
  • Page 175 – INDEX
Loading the manual

COMPASS USER GUIDE

Galileo

616

Keep these important operating instructions.

Check www.meyersound.com for updates.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 3 - TABLE OF CONTENTS

TABLE OF CONTENTS Documentation Overview ix About this Document ix About Meyer Sound xvi Technical Support xvii Chapter 1: Start Here 1 System Requirements 1 Installing Compass and Virtual Galileo 2 Running Compass with Virtual Galileo 3 Running Compass with Galileo 6 Chapter 2: Compass Overview 9 C...

Page 5 - List of Figures

List of Figures Illustrated User Interface Element Names 10 Low Pass 58 2nd Order High Pass 58 Elliptical High Pass 58 Compass Preferences Page 71 Channel Linking Preferences Page 76 Galileos Page 86 Galileo Project Page 96 Galileo Network Settings Page 102 Galileo I/O Settings Page 103 Galileo SIM3...

Page 7 - List of Tables

List of Tables Modifier Key Name Conventions xi User Interface Element Name Conventions xi Mouse Action Conventions xiii Keyboard Action Conventions xiv Typographic Conventions xiv Symbol Conventions xv Delay Unit Ranges 59 Screen Resolutions and Recommended User InterfaceScales 73 Keyboard Modifier...

Other Meyer Sound Models

All Meyer Sound Other