Radiance Multi-Rate Line Card Line Card: R380-SS ______ Multi-rate SFP to SFP Small Form-Factor Pluggable (SFP) Multimode Optics: O211-M5 ______ 1 Gbps SFP LC (multimode, 500 m)O221-M5 ______ Multi-rate SFP LC (multimode, 1.06 Gbps to 2.125 Gbps, 500 m)O280-M2 ______ Multi-rate SFP LC (multimode, 45...
Page 4 - Table of Contents; Radiance Multi-Rate Line Card Installation & User Guide
4 Table of Contents Radiance Multi-Rate Line Card Installation & User Guide Overview ............................................................................................................... 5 Installation Guide .................................................................................
Page 5 - Radiance Multi-Rate Line Card 5; Overview; or
Radiance Multi-Rate Line Card 5 Overview The Radiance multi-rate line card with dual small form-factor pluggable(SFP) optics provides a simple and versatile solution for converting betweentwo physical data formats. Use it to connect multimode to singlemode fiber, orsinglemode fiber with different wa...
Page 7 - Radiance Multi-Rate Line Card 7; • Manageable using Metrobility’s NetBeacon and WebBeacon element
Radiance Multi-Rate Line Card 7 • Operates in any Metrobility chassis enclosure such as the Radiance R5000, R1000, R400, R200, or RD-20. • Manageable using Metrobility’s NetBeacon and WebBeacon element management software, or any standard SNMP-based managementapplication.
Page 8 - Installation Guide; Unpack the Line Card; Default DIP Switch Settings; When setting DIP switches
8 Installation Guide Installation Guide * DIP switches can also be managed via console commands or through Metrobility NetBeacon orWebBeacon management software. Refer to the Command Line Interface Reference Guide, NetBeacon Element Management Software Installation & User Guide or WebBeacon Mana...
Page 9 - Radiance Multi-Rate Line Card 9; Configuring the Data Rate
Radiance Multi-Rate Line Card 9 Configuring the Data Rate SW2 is used to set the initial data rate on the R380. The data rate isdetermined by the 6-bit binary code derived from the position of theDIP switches. The table below describes the settings supported by themulti-rate line card. 1=UP, 0=DOWN....
Page 10 - Refer to
10 Installation Guide Loopback (LBCK) Switch Loopback is enabled independently on each port. When loopback isenabled, the port’s transmitter is connected to its receiver, thus return-ing incoming data back to the sender. Use LBCK1 to set loopback onPort 1, and LBCK2 for Port 2. By default, LBCK is d...
Page 11 - Radiance Multi-Rate Line Card 11; Install the SFP Optics; To install the optics, align the SFP module so the receiver (
Radiance Multi-Rate Line Card 11 Install the SFP Optics The R380 line card requires two small form-factor pluggable (SFP)optics. Optics are shipped separately. The table below lists the recom-mended optics to use based on the network protocol and fiber type. s c i t p O P F S d e d n e m m o c e R l...
Page 12 - Install the Line Card; • Grasp the card by the front panel as shown.
12 Installation Guide MULTIRATE 1 2 LB BP PWR SD RX TX RX TX RX TX SEC LK AT LB BP SD IMPORTANT: The multi-rate line card is designed and tested tooperate using only Metrobility-supplied SFP transceivers. Safety,performance, and reliability are guaranteed only when Metrobility-supplied transceivers ...
Page 13 - Radiance Multi-Rate Line Card 13; flush and even with the top and bottom edges of the chassis.; Connect to the Network
Radiance Multi-Rate Line Card 13 5 • Insert the card into a slot on the chassis making sure that the top and bottom edges of the circuit board are aligned with the top and bottomcard guides in the chassis. Do not force the card into the chassisunnecessarily. It should slide in easily and evenly. • S...
Page 14 - For more information about optics, refer to
14 Installation Guide Model # Fiber Type Max Distance O211-40 ........................... singlemode ................................... 40 kmO211-70 ........................... singlemode ................................... 70 kmO211-1A ........................... singlemode ..........................
Page 15 - Radiance Multi-Rate Line Card 15; For information on replacing the SFP transceiver, refer to
Radiance Multi-Rate Line Card 15 • The port’s receiver detects the presence of optical power andthe port’s CDR circuitry has locked onto the incoming signal. For information on replacing the SFP transceiver, refer to Changing the SFP Optics . BWDM InterfaceThe bidirectional wavelength division multi...
Page 16 - User Guide; LED Operation; The function of each LED is as follows:
16 User Guide User Guide This section contains information regarding the operating features of theRadiance multi-rate line card. LED Operation Several LEDs are visible on the front panel. These include the power (PWR),signal detect (SD), loopback (LB), and bypass (BP) LEDs. There are separatesignal ...
Page 17 - Radiance Multi-Rate Line Card 17; SFP Monitors
Radiance Multi-Rate Line Card 17 SFP Monitors Advanced management capabilities on the Radiance multi-rate line card enablesthe monitoring of the following parameters for each SFP port transceiver withdigital diagnostics. • Optical transmit power in dBm• Optical receive power in dBm• SFP transceiver’...
Page 18 - Loopback
18 User Guide Loopback The Radiance multi-rate line card features loopback testing capability to helpverify proper operation and to isolate problems within a particular segment ofthe network. During loopback, the LBK LED is yellow. Loopback is enabled/disabled in two ways: (1) setting the LBCK DIP s...
Page 19 - Radiance Multi-Rate Line Card 19
Radiance Multi-Rate Line Card 19 Dual-Port Loopback In this mode, data on both ports of the multi-rate line card are looped back totheir sending devices. Dual-port loopback is configurable through hardware orsoftware by enabling loopback on Port 1 and Port 2 simultaneously. Local Multi-Rate Line Car...
Page 20 - Link Loss Return
20 User Guide Link Loss Return Both ports on the Radiance multi-rate interface line card are designed with LinkLoss Return functionality for troubleshooting remote connections. When LLR isenabled * , the port’s transmitter shuts down if its receiver fails to detect a valid link signal. LLR should on...
Page 21 - Radiance Multi-Rate Line Card 21; Link Loss Carry Forward; , the ports do not transmit a signal
Radiance Multi-Rate Line Card 21 Link Loss Carry Forward The Radiance multi-rate line card incorporates LLCF to assist in troubleshootinga remote connection. When LLCF is enabled * , the ports do not transmit a signal until they receive a signal from the opposite port. When a lost link signal isretu...
Page 22 - Topology Solutions; Coarse Wavelength Division Multiplexing (CWDM); Connections to the end user are shown in dark gray.
22 User Guide Topology Solutions Enterprise Switch Workgroup Hub Fiber Optic Links Copper Links Switch Switch PC running NetworkManagement Software Servers Enterprise Radiance R5000 Central Service Platform with Multi-Rate Line Cards remote connection Radiance R5000 with R380 Line Cards Radiance R40...
Page 23 - Radiance Multi-Rate Line Card 23
Radiance Multi-Rate Line Card 23 Central Office Drop & Insert Drop & Insert Drop & Pass Drop & Pass Drop & Pass Radiance R5000 with R380 Line Cards Radiance R4000with 4-Channel CWDM Mux/Demux Modules RING TOPOLOGY Radiance R1000with R380 Line Card Radiance R1000with R380 Line Car...
Page 24 - Changing the SFP Optics; WARNING: Avoid looking into the laser or cable.; Align the new SFP module so the receiver (
24 User Guide Changing the SFP Optics The multi-rate line card supports two replaceable small form-factor pluggable(SFP) transceivers. This section explains how to remove and install the optics onthe card. Metrobility SFP transceivers are hot-swappable. IMPORTANT: Use only Metrobility-supplied SFP t...
Page 25 - Radiance Multi-Rate Line Card 25; Technical Specifications; m multimode
Radiance Multi-Rate Line Card 25 Technical Specifications Data Rate ____________________ 44.7 Mbps to 2.7 Gbps, depending on optics Power Requirements _______________________________ 5 V DC @ 1 A, 5 W EnvironmentalOperating Temperature _____________________________________ 0 to 50 ° C Storage Temper...
Page 27 - Radiance Multi-Rate Line Card 27; m singlemode
Radiance Multi-Rate Line Card 27 Singlemode Fiber Optic Plug-in (O383-20-55) for BWDMConnector _____________________________________________________ SCTX Wavelength ____________________________________________ 1550 nmRX Wavelength ____________________________________________ 1310 nmData Rate _______...
Page 29 - Radiance Multi-Rate Line Card 29
Radiance Multi-Rate Line Card 29 Singlemode Fiber Optic Plug-in (O281-80)Connector _____________________________________________________ LCWavelength _______________________________________________ 1550 nmData Rate ____________________________________ 125 Mbps to 155 MbpsRX Input Sensitivity __ -34 ...
Page 31 - Radiance Multi-Rate Line Card 31
Radiance Multi-Rate Line Card 31 s h t g n e l e v a W s c i t p O M D W C l e d o M r e b m u N h t g n e l e v a W s r e b m u N l e d o M h t g n e l e v a W 1 3 - 0 8 - 1 1 4 O m n 0 1 3 1 , 7 4 - 0 4 - 3 1 4 O , 7 4 - 0 8 - 1 1 4 O 7 4 - 0 8 - 3 8 4 O , 7 4 - 0 8 - 3 1 4 O m n 0 7 4 1 3 3 - 0 8...
Page 32 - Acronyms and Abbreviations
32 User Guide Acronyms and Abbreviations BP Bypass BWDM Bidirectional Wavelength Division MultiplexingCDR Clock and Data Recovery CDRB Clock and Data Recovery BypassCWDM Coarse Wavelength Division MultiplexingdB Decibel dBm Decibels relative to 1 mW of power (0 dBm equals 1 mW) DS Digital Signal ESC...
Page 33 - Radiance Multi-Rate Line Card 33; Product Safety, EMC and Compliance Statements; This equipment complies with the following requirements:
Radiance Multi-Rate Line Card 33 Product Safety, EMC and Compliance Statements This equipment complies with the following requirements: • UL• CB• CSA• EN60950 (safety)• FCC Part 15, Class A• EN55022 Class A (emissions)• ICES-003 Class A (emissions)• EN55024: 1998 (immunity)• IEC 825-1 Classification...
Page 34 - Warranty and Servicing; . If product was not purchased directly from Metrobility,
34 User Guide Warranty and Servicing Three-Year Warranty for the Radiance Multi-Rate Line CardMetrobility Optical Systems, Inc. warrants that every Radiance multi-rate linecard will be free from defects in material and workmanship for a period ofTHREE YEARS from the date of Metrobility shipment. Thi...
Page 35 - Radiance Multi-Rate Line Card 35
Radiance Multi-Rate Line Card 35 ADDITIONAL IMPORTANT WARRANTY INFORMATION:The Radiance multi-rate line card is designed to operate using only theMetrobility-supplied small form-factor pluggable (SFP) transceivers specified inthis manual. The use and installation of parts not included in this docume...
Page 36 - Product Manuals; Product Registration
Product Manuals The most recent version of this manual is available online at http://www.metrobility.com/support/manuals.htm Product Registration To register your product, go to http://www.metrobility.com/support/registration.asp 25 Manchester Street, Merrimack, NH 03054 USA tel: 1.603.880.1833 • fa...