Maytag MLG32PD3- Installation Manual
Maytag MLG32PD3– Installation Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Retain This Manual In A Safe Place For Future Reference; “IMPORTANT NOTE TO PURCHASER”; Important
- Page 3 – IMPORTANT; (Occupational Safety and Health Administration); CHILDREN SHOULD NOT BE ALLOWED TO PLAY ON OR NEAR THE DRYERS.; CHILDREN SHOULD BE SUPERVISED IF NEAR DRYERS IN OPERATION.; DRYERS SHOULD NEVER BE LEFT UNATTENDED WHILE IN OPERATION.; CAUTION; DO NOT; DO NOT; USE DRYER IN THE PRESENCE OF DRY CLEANING FUMES.; WARNING
- Page 4 – DRYER MUST
- Page 5 – Table of Contents
- Page 7 – SECTION I; IMPORTANT INFORMATION; A. RECEIVING and HANDLING; The basket (tumbler) section of the dryer; ALL
- Page 8 – B. SAFETY PRECAUTIONS; For your safety, the information in this manual; service panels removed. PERSONAL INJURY or FIRE COULD RESULT.; Dry only water washed fabrics.
- Page 9 – Failure to do so will VOID THE WARRANTY.; WARNING: PERSONAL INJURY or FIRE COULD RESULT.
- Page 10 – SECTION II; SPECIFICATIONS
- Page 11 – GAS
- Page 12 – SECTION III; INSTALLATION PROCEDURES; should be; will be; needed throughout various phases in the installation of; B. LOCATION OF THE DRYER
- Page 14 – C. DRYER ENCLOSURE REQUIREMENTS; is; Allowances
- Page 16 – E. EXHAUST REQUIREMENTS; must not exceed
- Page 17 – must be; The duct; use screens or caps on the outside opening of the exhaust duct work.
- Page 18 – illustration; cannot
- Page 20 – F. ELECTRICAL INFORMATION; The use of aluminum wire will VOID THE WARRANTY.; For personal safety and proper operation, the dryer
- Page 22 – Contact factory for electrical information not listed.; LECTRIC; A separate circuit breaker
- Page 23 – VOIDING THE WARRANTY.; WARNING: FIRE or EXPLOSION COULD RESULT.; Any burner changes or conversions
- Page 24 – Gas Inlet Size
- Page 25 – at the gas valve pressure tap of each dryer for
- Page 26 – Test; H. PREPARATION FOR OPERATION
- Page 27 – During the purging period, check to be sure that; gas shutoff valves are open.; is not; established after the first attempt, the heat circuit in the DSI; column pressure
- Page 28 – BASKET COATING; J. SHUT DOWN INSTRUCTIONS
- Page 29 – SECTION IV; OPERATING INSTRUCTIONS; A. STARTING THE DRYER
- Page 30 – SECTION V; SERVICE/PARTS INFORMATION; When contacting the; Maytag Company; , be sure to give them the correct; model; and; serial; so that your inquiry is handled in an expeditious manner.
- Page 31 – SECTION VI; WARRANTY INFORMATION; installation date
- Page 32 – SECTION VII; ROUTINE MAINTENANCE; WARNING: LINT FROM MOST FABRICS IS HIGHLY COMBUSTIBLE; SUGGESTED CLEANING SCHEDULE
- Page 33 – OBSTRUCT THE FLOW OF COMBUSTION AIR and VENTILATION
- Page 35 – SECTION VIII; DRYER DATA LABEL INFORMATION; A. DATA LABEL LOCATION
- Page 38 – SECTION IX; PROCEDURE FOR FUNCTIONAL CHECK
Part No. 113158
MLG32PD3
30 lb. Stacked Model
Installation Manual
101000GS/rar
WARNING: For your safety the
information in this manual must be
followed to minimize the risk of fire or
explosion or to prevent property damage,
personal injury or death.
Do not store or use gasoline or other flammable
vapor and liquids in the vicinity of this or any
other appliance.
WHAT DO YOU DO IF YOU SMELL GAS
* Do not try to light any appliance.
* Do not touch any electrical switch; do not use
any phone in your building.
* Clear the room, building or area of all
occupants.
* Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
* If you cannot reach your gas supplier, call the
fire department.
Installation and service must be performed by a
qualified installer, service agency or the gas
supplier.
AVERTISSEMENT: Assurez-vous de bien
suivre les instructions données dans cette
notice pour réduire au minimum le risque
d’incendie ou d’explosion ou pour éviter tout
dommage matériel, toute blessure ou la mort.
Ne pas entreposer ni utiliser d’essence ni
d’autres vapeurs ou liquides inflammables dans
le voisinage de cet appareil ou de tout autre
appareil.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR
DE GAZ:
* Ne pas tenter d’allumer d’appareil.
* Ne touchez à aucun interrupteur. Ne pas
vous servir des téléphones se trouvant dans
le bâtiment où vous vous trouvez..
* Évacuez la pièce, le bâtiment ou la zone.
* Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions
du fournisseur.
* Si vous ne pouvez rejoindre le fournisseur
de gaz, appelez le service des incendies.
L’installation et l’entretien doivent être assurés
par un installateur ou un service d’entretien
qualifié ou par le fournisseur de gaz.
RETAIN THESE INSTRUCTIONS IN A SAFE
PLACE FOR FUTURE REFERENCE
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
Retain This Manual In A Safe Place For Future Reference This product embodies advanced concepts in engineering, design, and safety. If this product is properly maintained, it will provide many years of safe, efficient, and trouble-free operation. ONLY qualified technicians should service this equipm...
IMPORTANT YOU MUST DISCONNECT and LOCKOUT THE ELECTRIC SUPPLY and THE GASSUPPLY BEFORE ANY COVERS or GUARDS ARE REMOVED FROM THE MACHINETO ALLOW ACCESS FOR CLEANING, ADJUSTING, INSTALLATION, or TESTINGOF ANY EQUIPMENT per OSHA (Occupational Safety and Health Administration) STANDARDS. CHILDREN SHOUL...
WARNING The dryer must never be operated with any of the back guards, outer tops, or servicepanels removed. PERSONAL INJURY or FIRE COULD RESULT. IMPORTANT PLEASE OBSERVE ALL SAFETY PRECAUTIONS displayed on the equipment and/orspecified in the installation manual included with the dryer. The wiring ...