TECHNICAL INFORMATION

F4710

Installation & Operating Instructions for the

Owner’s Installation ,Manual

WARNING:SHUT

POWER

OFF

AT

FUSE

OR

CIRCUIT

BREAKER

THANK YOU FOR YOUR PURCHASE

SAFETY RULES

SKU

Light CCT.

110-120V AC

E12 6*25W(MAX) EXCLUDE

F4710

40W

Thank you for purchasing this quality product. To ensure correct function and safety, please read and save all

instructions before using the product

1. Mounting Bracket
2. Canopy screws
3. Canopy
4. Decorative canopy cover
5. Downrod&hanger ball
6. Bolt
7.Coupling cover

8. Lock pin
9. Top housing
10. Blades
11. Base plate
12. Light kit
13.

Garnish nut

14. Crystal strip

15.
16.
17.

Wood screws

18.

Expansion screws

19.

Plastic anchor

20.

Balance tapes
Remote control set

BEFORE INSTALLATION

Unpack your fan and check the contents.You should have followings:









1.

To reduce the risk of electric shock, insure electricity has been turned off at the circuit breaker or fuse

box before beginning.

2.

All wiring must be in accordance with the National Electrical Code and local electrical codes. Electrical

installation should be performed by a qualified licensed electrician.

3.

WARNING: To reduce the risk of electrical shock and fire, do not use this fan with any solid-state fan

speed control device.

4.

WARNING: To reduce the risk of fire, electric shock, or personal injury, mount to outlet box marked

"Acceptable for Fan Support of 45kg (99.12 lbs.) Or Less" and use mounting screws provided with the
outlet box. Most outlet boxes commonly used for the support of light fixtures are not acceptable for fan
support and may need to be replaced. Due to the complexity of the installation of this fan, a qualified

5.

The outlet box and support structure must be securely mounted and capable of reliably supporting a

minimum of 45KGS. Use only UL Listed outlet boxes marked FOR FAN SUPPORT.

6.

The fan must be mounted with a minimum of 7 feet clearance from the trailing edge of the blades to

7.

Avoid placing objects in the path of the blades.

8.

To avoid personal injury or damage to the fan and other items, be cautious when working around or

cleaning the fan.

9.

Do not use water or detergents when cleaning the fan or fan blades. A dry dust cloth or lightly dampened

cloth will be suitable for most cleaning.

10.

After making electrical connections, spliced conductors should be turned upward and pushed carefully

up into the outlet box. The wires should be spread apart with the grounded conductor and the equipment-

grounding conductor on one side of the outlet box.

11.

Electrical diagrams are for reference only.

12.

The fan is suitable for indoor use only.

13.

Please do not use the fan in a specific environment like high temperature envitonmet,high

radiation environment,lampblsck or other abnormal use environments.

INSTALLING THE FAN

Tools Required: Phillips screwdriver, Pair of pliers, straight slot screwdriver, adjustable wrench, step ladder, and wire cutters.

INSTALLLING THE MOUNTING BRACKET

The ceiling fan must be installed in a location so that the blades are 12”( 300mm) spacing from the tip of the blade to the nearest objects or walls. When hanging the Fan

REMEMBER to turn off the power. Follow the instruction below to hang your fan properly:

NOTE:Hanger after the installation must be able to withstand the weight of 45kg or more

1. For concrete ceiling, drill two holes

in

the ceiling and secure the mounting

bracket to the ceiling with two

φ0.32″(8mm)

distance between

the two holes should be appropriate

expansion screws, flat washers,nuts

provided and tighten with a spanner.

2. For wood ceiling, Secure the

mounting bracket to the ceiling is

capable of carrying a load of at least

100lbs(45kgs) with two long mounting

screws and washers provided. Be sure

at least 0.12”(30mm) of the screw is

threaded into the support.

3. For installing to outlet box, secure the outlet box

directly to the building structure. Use appropriate

fasterners and building materials. The outlet box

and its support must be able to fully support the

moving weight of the fan(at least 100lbs). Use a UL

listed metal outlet box. Do not use a plastic outlet

box. Figure 1& 2 examples to mount the outlet box.

4. Refer to the Fig. in right for mounting

when the ceiling is angled max. 15

degree angle.

licensed electrician is strongly recommended.

the floor.

Rated Voltage

Rated power(motor)

F4710

Installation & Operating Instructions for the

Owner’s Installation ,Manual

WARNING:SHUT

POWER

OFF

AT

FUSE

OR

CIRCUIT

BREAKER

BEFORE INSTALLATION

Unpack your fan and check the contents.You should have followings

1. Mounting Bracket
2. Canopy screws
3. Canopy
4. Decorative canopy
cover
5. Downrod&hanger ball
6. Bolt
7. Coupling cover
8. Lock pin
9. Top housing
10. Blades
11. Base plate
12. Light kit
13.

Garnish nut

14. Crystal strip
15.
16.
17.

Wood screws

18.

Expansion screws

19.

Plastic anchor

20.

Balance tapes
Remote control set

All rights reserved.

Made in China

All rights reserved.

Made in China

1

7

9

2

3

4

6

5

8

10
11

12

13

14

15

1

7

9

2

3

4

6

5

8

10
11

12

13

14

15

16 17 18 19

2 4 8

hr

1

2

3

20

Crystal hook

16 17 18 19

2 4 8

hr

1

2

3

20

Crystal hook

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Matrix Decor Fans Models

All Matrix Decor Fans