Loading the manual

7629661 BIN THERMOSTAT

WATER SHIELD ASSY.

QM-30 Installation Instructions Only


IF USED ON A QM-20, REPLACEMENT BRACKET AND SHIELD ARE NOT USED.

INSTALL BIN THERMOSTAT ONLY.

1.

Remove back panel.

2.

Remove the two screws holding the bin thermostat to the bracket. Drill out the rivets that hold the bracket to the cabinet.
Remove and discard the bracket.

3.

Drill new 9/64” [3.5mm] diameter holes in the cabinet exterior flange 1.25” [31.75mm] above the existing holes. Attach the
thermostat to the shield using the M4 x 7 screws supplied. Attach the shield to the cabinet using the 8-32 x .500” screws
supplied.

4.

Press the shield firmly into the foam. Seal the top, left side, and right seams with RTV.

5.

Locate and drill 3/16” [4.76mm] diameter holes in the lower back panel above the water inlet valve. Install the water inlet
valve shield using two 10-24 x .500” hex head screws supplied.

6.

Install the back panel.





































Manitowoc Ice, Inc.

2110 South 26 Street, P.O. Box 1720, Manitowoc, WI 54221-1720 USA
Telephone 920-682-0161, Fax - Sales: 920-683-7589, Service/Parts: 920-683-7585, Other: 920-683-7879

8012133

Web Site - www.manitowocice.com

Rev. 07/09/04

Bin Thermostat Shield

Water Inlet Valve Shield

3.875”

[98.43mm]

.625”

[15.88mm]

1.375”

[34.93mm]