Lowrance EP-80R TH - Manual

Lowrance EP-80R TH

Lowrance EP-80R TH – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
Page: / 32

Table of Contents:

  • Page 2 – The NMEA 2000 red female to blue female adapter cable allows users; Caution; Tools and Supplies; Setup and Installation of NMEA 2000 Net-
  • Page 3 – LowranceNET Node Kit for a NMEA 2000 network. Includes a 2-foot; Recommended Tools and supplies; high quality, marine grade; Installation; The EP-80R TH thru-hull temperature sensor can be mounted in any; the transom. The hole should be below the waterline.
  • Page 4 – module, add sealant on the inside of the hull and tighten the nut; Do not use a wrench to tighten the nut!
  • Page 5 – Cross section of transom showing EP-80R TH installed; Connecting to a NMEA 2000 Network; There are two types of LowranceNet red connectors: the single T con-
  • Page 6 – Network Backbone and Network Nodes; To pick up a phone and be able to hear a conversation from another; NMEA 2000 network node located at the end of a NMEA 2000 backbone.; If you have a double T Connector on your network that is not at-
  • Page 7 – Adding a Network Node; In this example, a new device is added to the NMEA 2000 bus by install-; Additional Network Information
  • Page 8 – Notes
  • Page 9 – Temp Configuration; Boat Setup; To execute Boat Setup:
  • Page 10 – Boat Setup Reset; Hit menu to reset Eng/Tnk; EP-80R TH Configuration; Hit Menu to Cfg Temp Sns
  • Page 12 – Displaying EP-80R TH Temp Sensor Data; Page Screen Rotation
  • Page 13 – Customizing Pages
  • Page 16 – Press ENTER to reset Eng/Tnk Cfg; Press Enter to Configure Temp Sen-
  • Page 17 – Press Menu to UnConfig Device Name; Bus Devices highlighted in the System Setup menu (left). Searching; Name Already Selected
  • Page 19 – Press Enter to add the selected page
  • Page 23 – The LMS-525cDF is one of many Lowrance display units that may be; NMEA 2000 Menu/Networking Menu
  • Page 24 – EP-80R TH Temp Sensor Configuration; Device Name; You do not have to change the device name to
  • Page 25 – Are you sure you wish to change this
  • Page 26 – Unconfiguring a Temp Sensor; Are you sure you wish to change this device's configuration?; Reconfiguring a temp sensor
  • Page 27 – Displaying EP-80R TH Temp Sensor Information; NOTE
  • Page 31 – LOWRANCE ELECTRONICS
  • Page 32 – How to Obtain Service...; ...outside Canada and the USA:; Accessory Ordering Information
Loading the manual

1

Pub. 988-0154-442

EP-80R TH

Electronic Thru-Hull Temp Sensor

Installation and Configuration Instructions

This document shows how to install an EP-80R TH thru-hull temp sen-

sor and how to connect it to a NMEA 2000

®

network. It also provides

instructions on how to configure your temp sensor with Lowrance digi-

tal gauges (LMF-200 & LMF-400) and display units.
NMEA 2000 is the communication bus standard developed by the Na-

tional Marine Electronics Association (NMEA) for use in boats.

Lowrance has introduced a line of products that can communicate over

a NMEA 2000 network (LowranceNet).
All Lowrance NMEA 2000 capable devices are either NMEA 2000 certi-

fied or certification is pending.

CAUTION:

Installing LowranceNET NMEA 2000 devices is

significantly

different

from installing earlier Lowrance components without

NMEA 2000 features. You should read all of the installation in-
structions before proceeding. Decide where you want to install
all components before drilling any holes in your vessel.

Some sonar or GPS units may require a software upgrade to display

NMEA 2000 data correctly. For free software upgrades or additional

information on the LowranceNet NMEA 2000

®

network system, visit

our web site, www.lowrance.com.

The EP-80R TH temperature sensor.

Red NMEA 2000
connector

Thru-hull
temp sensor
module

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - The NMEA 2000 red female to blue female adapter cable allows users; Caution; Tools and Supplies; Setup and Installation of NMEA 2000 Net-

2 Some sonar or GPS units may require a software upgrade to display NMEA 2000 data correctly. For free software upgrades or additional information on the LowranceNet NMEA 2000 ® network system, visit our web site, www.lowrance.com. The EP-80R TH consists of the temp sensor module, a red cable connec...

Page 3 - LowranceNET Node Kit for a NMEA 2000 network. Includes a 2-foot; Recommended Tools and supplies; high quality, marine grade; Installation; The EP-80R TH thru-hull temperature sensor can be mounted in any; the transom. The hole should be below the waterline.

3 LowranceNET Node Kit for a NMEA 2000 network. Includes a 2-foot extension cable, T connector and two 120-ohm terminators. Recommended Tools and supplies Recommended tools for this job include: drill, 1/8" (3 mm) drill bit for pilot hole, 1-1/16 (27 mm) hole saw with a blade type appropriate fo...

Page 4 - module, add sealant on the inside of the hull and tighten the nut; Do not use a wrench to tighten the nut!

4 Afterwards, clean the area around the hole with detergent or alcohol. This will establish a good surface for the adhesive. 5. Using a high quality, marine-grade above- or below-waterline seal- ant/adhesive compound, apply a 1/8" (3 mm) bead of sealant around the lip of the EP-80R TH housing. 6...

Other Lowrance Models

All Lowrance Other