Page 3 - List of Contents; Conference equipment and channel selectors . 8; Maximum number of units to be connected .. 25
Danish Interpretation Systems User Manual Copyright © 2007 DIS CU6005 6010 6011 REV V.DOC 16-07-2007 No part of this publication may be reproduced or utilised in any form or by any means without permission in writing from the publisher. List of Contents List of Contents ................................
Page 5 - Important; Compliancy; The equipment must be connected to earth; Labels
Danish Interpretation Systems User Manual Manual 01 18 04438 5 Important Compliancy The equipment has been tested and found to comply with the limits of the following standards for digital devices: • EN55103-1 (Emission) • EN55103-2 (Immunity) • EN60065 safety • UL6500 safety • FCC rules part 15, cl...
Page 6 - Cleaning & Repacking
Danish Interpretation Systems User Manual Manual 01 18 04438 6 To avoid moisture condensations do not install the unit where the temperature may rise rapidly. When installing the unit inside a 19” rack, observe that the rack is properly ventilated. The maximum allowed temperature inside the rack is ...
Page 7 - Description of the DCS 6000 system; Features
Danish Interpretation Systems User Manual Manual 01 18 04438 7 Description of the DCS 6000 system Features The DCS 6000 system has the following main features: • Fully digital • Excellent sound quality • “State of the Art” fully digital integrated interpretation, discussion and voting system offerin...
Page 8 - System components; Central equipment etc.
Danish Interpretation Systems User Manual Manual 01 18 04438 8 System components The CU 6005/6010/6011 Central Unit supports all available units in the DCS 6000 series: Central equipment etc. EX 6010 Extension Unit PS 6000 Power Supply AO 6004 Audio Output box AO 6008 Audio Output box RP 6004 Repeat...
Page 9 - Operating instructions; General description; This manual describes all features available
Danish Interpretation Systems User Manual Manual 01 18 04438 9 Operating instructions CU 6010 Central Unit General description The CU 6010 Central Unit for the DCS 6000 is the heart of the system. One CU 6010 is needed in each DCS 6000 system. The CU 6010 consist of four main parts: • Main processor...
Page 10 - Front plate layout; Front plate controls
Danish Interpretation Systems User Manual Manual 01 18 04438 10 User Controls, indications & connectors Front plate layout The front plate layout of the CU 6010 Central Unit consists of a large illuminated LCD display and 8 buttons for setting up/controlling the system: Details of display -Audio...
Page 11 - Symbols
Danish Interpretation Systems User Manual Manual 01 18 04438 11 Buttons The buttons below and to the left of the display are used when stepping through the different menus and for setting up the system: • Four select buttons Four buttons placed on the left-hand side of the display. Each button is as...
Page 12 - Back Panel Layout
Danish Interpretation Systems User Manual Manual 01 18 04438 12 Back Panel Layout Back Panel Connectors Mains Power connector Connection for mains power. See specs. Analog Audio Line input XLR Input connector. For connection of external Line input signal i.e. the Floor (Speaker) signal from another ...
Page 13 - Audio control
Danish Interpretation Systems User Manual Manual 01 18 04438 13 A selection is made in the Main menu by scrolling through the menu items with the Up/Down buttons, and pressing the Select button associated with the desired menu item. When scrolling through the menu items, the Main menu wraps around t...
Page 14 - Delegate setup
Danish Interpretation Systems User Manual Manual 01 18 04438 14 Delegate setup The “Delegate setup” menu comprises the following entries: • Max Speakers • Max. Requests • Operation Mode • Voice Detection • Auto Off Setup Max Speakers This menu point has two settings: • Max. Total Speakers • Max. Del...
Page 15 - This menu point has two settings:
Danish Interpretation Systems User Manual Manual 01 18 04438 15 More delegates will be put in the request queue when they press their ON/OFF buttons, until the maximum of requests is reached. Their green ‘Request’ lamps will light up steadily. When one of the turned ON microphone units is switched o...
Page 16 - Interpretation setup
Danish Interpretation Systems User Manual Manual 01 18 04438 16 This setting is used to set the time from the delegate stops talking until the microphone turns off. The default value is 4 sec. Auto Off Setup This menu point has two settings: • Auto Off • Auto Off time Those settings determine the be...
Page 17 - A interrupt A; Ambient microphone
Danish Interpretation Systems User Manual Manual 01 18 04438 17 • Complete Lock With this setting an interpreter cannot switch on his microphone to any occupied interpreter channel. This is the default setting. • No Lock With this setting an interpreter turning on his microphone to any occupied inte...
Page 18 - Security setup
Danish Interpretation Systems User Manual Manual 01 18 04438 18 The Chain info menu displays information to the user about units connected to the CU. The information is divided into Chain A, Chain B and total. Found units are connected units, where the communication is maintained, and expected units...
Page 19 - License info menu; VOX option; Firmware info menu
Danish Interpretation Systems User Manual Manual 01 18 04438 19 The load is aborted with the Menu button and accepted with the Enter button. In both cases, the menu system returns to the Main menu. Save configuration If the “Save configuration” item is chosen this confirmation display is shown: If t...
Page 20 - Normal Operation; Please refer to the SW 6000 manuals.; Schematics volume/gain settings; Set the Mic>Loudspk to 0dB; Apply the signal to the Input connector
Danish Interpretation Systems User Manual Manual 01 18 04438 20 The user returns to the main menu by pressing either the Menu button or the Enter button. Normal Operation Powering up Switch on power at the CU 6010. After powering up, the display on the CU 6010 is showing the Start-up screen: After i...
Page 22 - Main processor board with Power PC and DSP
Danish Interpretation Systems User Manual Manual 01 18 04438 22 CU 6005 Central Unit General description The functionality of CU 6005 is basically identical to the CU 6010 Central Unit; however the main parts are slightly different: • Main processor board with Power PC and DSP • DCS-LAN Network Cont...
Page 23 - Identical to the CU 6010 Central Unit.
Danish Interpretation Systems User Manual Manual 01 18 04438 23 User Controls, indications & connectors Front plate layout Identical to the CU 6010 Central Unit. Front plate controls Identical to the CU 6010 Central Unit. Back Panel Layout Back Panel Connectors As the CU 6010 Central Unit with t...
Page 24 - System Setup; General guidelines; Please observe the following guidelines:; Built into 19” Racks
Danish Interpretation Systems User Manual Manual 01 18 04438 24 System Setup General guidelines Connect the CU 6005/6010/6011 to the various DCS 6000 units using Cat5 or Cat5e FTP or STP screened cables. The operation of the DCS 6000 units is found in the User Manual for the specific units. Please o...
Page 25 - Maximum number of units to be connected
Danish Interpretation Systems User Manual Manual 01 18 04438 25 Maximum number of units to be connected The following table shows the maximum number of units, which can be connected to each of the four outputs (A1, A2, B1 or B2) on a CU 6010/6011 Central Unit or on each output on an EX 6010 Extensio...
Page 28 - on a CU
Danish Interpretation Systems User Manual Manual 01 18 04438 28 MU 6040C/D and MU 6042D without connected loudspeaker – CU 6010/6011 This table shows the maximum number of MU 6040 Microphone Units, which can be connected to each of the four outputs (A1, A2, B1 or B2) on a CU 6010/6011 Central Unit o...
Page 30 - Typical schematics; The following schematics are showing various configurations:; Small conference microphone system with CU 6005
Danish Interpretation Systems User Manual Manual 01 18 04438 30 Typical schematics The following schematics are showing various configurations: Small conference microphone system with CU 6005 Small conference microphone system with CU 6010
Page 31 - Large size conference microphone system
Danish Interpretation Systems User Manual Manual 01 18 04438 31 Large size conference microphone system Microphone conference system with interpretation CU 6010
Page 34 - Small system with SW 6000 Conference Management Software
Danish Interpretation Systems User Manual Manual 01 18 04438 34 Small system with SW 6000 Conference Management Software
Page 35 - Large system with SW 6000 Conference Management Software
Danish Interpretation Systems User Manual Manual 01 18 04438 35 Large system with SW 6000 Conference Management Software
Page 36 - Appendix; Technical appendix; Cabling; Pin Function; RS 232 Serial connection; RS 422 Serial connection; Pin
Danish Interpretation Systems User Manual Manual 01 18 04438 36 Appendix Technical appendix Cabling CAT5 The DCS 6000 system uses CAT5, CAT5e or CAT6 FTP or STP cables with screened RJ45 connectors. EIA 568-B wiring shall be used. It is important to use only FTP or STP (screened) cables and screened...
Page 38 - Technical specifications; Connectors
Danish Interpretation Systems User Manual Manual 01 18 04438 38 Technical specifications Digital Section Sound quality ......... 24 bit audio @ 32 kHz sampling frequency Analogue Section Floor output signal type ......................... electronically balanced Nominal output level ....................