Lifebreath TFP3000 - Manual
Lifebreath TFP3000 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Lift the TFP into position.; Edge of TFP must be; TYPE 1 INSTALLATION; TFP; Figure 1; Figure 2
- Page 3 – TFP Connected to Heat Recovery Ventilator; LOCATION; F L O O R J O I S T S; TYPE 2 INSTALLATION; Figure 3; CAUTION
- Page 4 – Refer to “Mounting” under Type 2 Installations.; TYPE 3 INSTALLATION
1 TFP
4 mounting brackets
4 hanging straps
2 Red, 7” collar connections
4 8/32” X 3/4” sheet metal screws
8 8/32” X 3/8” sheet metal screws
4 pieces of mounting foam
1 set of installation \ operating instructions
1 warranty card
The TFP is equipped with a standard power supply,
on a 5’ 5” cable. Lighted ON/OFF switch.
Materials Supplied
Electrical
TFP-3000
0111
INSTALLATION MANUAL FOR TFP AIR CLEANER
Model TFP3000
Model TFP3000HEPA
The TFP can be installed in several different
ways. Please read all suggested methods before
attempting installation.
ATTENTION
The furnace fan and/or HRV must operate
continuously for Type 1 and Type 2 installations.
If they do not operate continuously, then
interlocking them electrically with the TFP is
acceptable. Consult a certified electrician.
ATTENTION
* LEAVE FOR HOMEOWNER
NOTE: Due to ongoing research and product development, specifications,
ratings and dimensions are subject to change without notice.
C US
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 TFP Directly Connected to Forced Air Heating System 1. Install 7” port collar (provided) on top and bottom of TFP (Fig. 1). Use (4) 8/32” X 3/8”screws (provided). 2. Remove protective backing from pieces offoam and stick them to the 4 corners of the TFPon the side being mounted against the plenum....
TFP Connected to Heat Recovery Ventilator LOCATION The TFP should be located in the main trunk of the fresh air to house line, after the Heat Recovery Ventilator (HRV) and before any branch lines. (Fig. 3) MOUNTING 1. Locate mounting bolts (4) on side of TFP cabinet for vertical hanging (Fig. 3) and...
TFP Independent Installation No HRV, Radiant Heating System LOCATION 1. A TFP is usually installed in a basement area where air flow noise will be negligible to the occupants. 2. A central location between the clean air supplygrille and return grille is recommended. MOUNTING Refer to “Mounting” unde...