Liebert PowerSure Personal – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
1
2
3
4
5
6
7
8
9
10
11
12
Table of Contents:
Page 2 – IMPORTANT SAFETY INSTRUCTIONS; SAVE THESE INSTRUCTIONS; Operate the UPS only from a properly grounded AC supply.
Page 3 – INTRODUCTION & SYSTEM DESCRIPTION; Reorient or relocate the receiving antenna.; MAJOR COMPONENTS; FRONT; BACK
Page 4 – PowerSure Personal; Line Diagram; INPUT
Page 5 – GENERAL INSTALLATION; Inches; T M
Page 6 – Before changing the supply fuse, turn off the UPS, and unplug the; Fuse Type
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
Page 2 - IMPORTANT SAFETY INSTRUCTIONS; SAVE THESE INSTRUCTIONS; Operate the UPS only from a properly grounded AC supply.
2 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important safety instructions that should be followed during the installation and maintenance of the UPS. Please read this manual thoroughly before attempting to install or operate this UPS. WARNING: To prevent the risk of ...
Page 3 - INTRODUCTION & SYSTEM DESCRIPTION; Reorient or relocate the receiving antenna.; MAJOR COMPONENTS; FRONT; BACK
3 INTRODUCTION & SYSTEM DESCRIPTION Congratulations on your choice of the Liebert PowerSure Personal Uninterruptible Power System (UPS). It provides conditioned power to microcomputers and other sensitive electronic equipment. NOTE: This equipment has been tested and found to comply with the lim...
Page 4 - PowerSure Personal; Line Diagram; INPUT
4 Normal Operation During normal operation, incoming utility power is supplied to the load as shown above. The utility power passes through the EMI/ RFI filters and TVSS circuitry and then through the transfer switch to the connected loads. The battery charger is operational whenever AC power is sup...
Page 5 - GENERAL INSTALLATION; Inches; T M
5 GENERAL INSTALLATION Liebert R Personal PowerSure TM Remove from Box Liebert R Personal PowerSure T M Check for Damage Liebert R Personal PowerSure T M 4 Inches 110 mm 32 0° - 40° C ° - 104° F Plug in Loads Plug UPS into AC Liebert R Personal PowerSure T M Liebert R Personal PowerSure T M Press ON...
Page 6 - Before changing the supply fuse, turn off the UPS, and unplug the; Fuse Type
6 MAINTENANCE The PowerSure Personal UPS requires very little maintenance. The batteries are valve regulated, nonspillable, lead acid, and require that they be kept charged to obtain their designed life. The UPS continuously charges the batteries when connected to the utility supply. W hen storing t...
7 COMMUNICATIONS The PowerSure™ Personal UPS contains a standard DB-9 receptacle located on the rear of the UPS unit. Several signals are provided on this port and are assigned as follows: PIN ASSIGNMENT DESCRIPTION 1 Low Battery (open collector) 2 No connection 3 No connection 4 On Battery Mode Shu...
Page 8 - TROUBLESHOOTING; PROBLEM
8 TROUBLESHOOTING If the UPS fails to operate properly, turn off the unit and repeat the steps in the installation section of this manual. If the problem persists, refer to the chart below: PROBLEM CAUSE SOLUTION UPS will not start Overload/Short Circuit Check fuse at rear of UPS. If blown, replace ...
Page 9 - LED & ALARM INDICATIONS; Startup
9 LED & ALARM INDICATIONS Startup Mode Green Red Alarm Action UPS Start Flash 1-2 sec. Flash 1-2 sec. Beep 1-2 sec. Press ON button for 2 seconds AC Mode Mode Green Red Alarm Indicates AC Normal ON OFF OFF UPS is on-line Check Battery ON Flash 10 sec. every 4 min. Flash 10 sec. every 4 min. Batt...
Page 11 - LIMITED WARRANTY
11 LIMITED WARRANTY Liebert Corporation extends the following LIMITED WARRANTY to the purchaser and to its customer (collectively referred to as the "Purchaser"): the enclosed Uninterruptible Power System (UPS) and components are free from defects in materials and workmanship under normal us...
Page 12 - Technical Support; OWER
12 Technical Support U.S.A. 1-800-222-5877 Outside the U.S.A. +1 614-841-6755 U.K. +44 1628 403 200 France +33 1 4 360 26 19 Germany +49 21669649340 Italy +39 2 98250 1 Netherlands +00 31 475 504050 E-mail [email protected] Web site www.liebert.com Worldwide FAX tech support +614-841-5471 The Comp...