Liebert MP-C5120 - Manual
Liebert MP-C5120 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – default = no password
- Page 3 – MP A; port of the MP-DS62 card on your MP Advanced Access Server.; None; HYPERTERMINAL SETTINGS
- Page 4 – Liebert Corporation; IP A; DDRESS; Press Enter to return to the Network Port Configuration menu.; THE; ping
1
L
IEBERT
MP™ A
DVANCED
P
OWER
S
TRIPS
Q
UICK
-S
TART
G
UIDE
: O
PEN
C
OMMS
EM
OR
MP A
DVANCED
A
CCESS
S
ER VER
W
HAT
’
S
I
NCLUDED
Make sure you have all the items that should be included with your Liebert MP Advanced Power Strip. If
any item is missing or damaged in shipping, file a damage claim immediately—see the user manual for
details.
• RJ-45 to RJ-45 configuration cable, 5 ft. (1.5m)
• RJ-45 to DB9 adapter for configuration cable
• 2 mounting brackets and 4 screws
• Quick-start guide
C
ONFIGURATION
WITH
O
PEN
C
OMMS
EM
1. Connect power to the DCN port on the OpenComms EM and to your MP Advanced Power Strip.
2. Connect the six-wire end of the serial cable provided with the OpenComms EM to the EIA-232 port of
your MP Advanced Power Strip.
3. Connect the other end (eight-wire) of the serial cable to either Serial 1 or Serial 2 of the
OpenComms EM.
4. Connect a straight-through CAT5 Ethernet cable from your network to the Ethernet port on the back
of the OpenComms EM.
A
SSIGN
AN
IP A
DDRESS
If your network uses static IP addresses and your computer has a Windows operating system, follow the
steps below. Otherwise, consult the OpenComms EM user manual (SL-28210).
1. Obtain an IP address for the OpenComms EM from your network administrator.
2. Insert the OpenComms EM CD in your computer’s CD drive.
3. Click on the
Start
button, then on
Run
, then
Browse
to the file
IPSET.exe
on the CD and click
Open
.
NOTE
These steps must be done on the same network segment where the OpenComms EM is connected.
POWER
1
2
3
4
5
6
8
8
EIA-232
Sensor
2
Sensor
1
Serial
2
Serial
1
Modem
DCN
Ethernet
Liebert MP
Advanced
Power Strip
(MP-C5120)
EIA-232 Port
Ethernet
Port
Serial Ports - Connect either
to Power Strip EIA-232 Port
Liebert OpenComms EM
(EM PDU Controller)
DCN Power Port
Mounting
Bracket on
either side
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 4. Click OK to open the IPSet window (at right). 5. In the Target area: a. Enter the OpenComms EM IP addressb. Enter your network’s Subnet Maskc. Enter your router’s IP address in the Default box. d. Enter the MAC address found on the bottom of your OpenComms EM. 6. Apply the changes. If the devic...
3 C ONFIGURATION WITH L IEBERT MP A DVANCED A CCESS S ERVER M AKE C ONNECTIONS 1. Connect power to the Liebert MP Advanced Access Server and turn the unit On (the On/Off switch is on the rear of the unit; some units do not have this switch; they are energized whenever their power cord is plugged int...
4 © 2005 Liebert CorporationAll rights reserved throughout the world. Specifications subject to change without notice. ® Liebert and the Liebert logo are registered trademarks of Liebert Corporation. All names referred to are trademarks or registered trademarks of their respective owners. SL-20812 (...