Liebert LM250120YARCE - Manual

Liebert LM250120YARCE

Liebert LM250120YARCE – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
Page: / 1
Loading the manual

Liebert Corporation • 1050 Dearborn Drive • PO Box 29186 • Columbus, OH 43229
Phone 607-724-2484 • Fax 607-722-8713 • US & Canada 800-288-6169
EMAIL: info@control-concepts.com • Web Site: www.Liebert.com

82241 Rev 1

Example Part Number:

LM250120YARCE

500kA per Phase (250kA per Mode),
120/208V 3-Phase Wye, All Mode,
Rotary Disconnect, LED’s, Alarm,

Counter, & Dual Form C Contacts,
NEMA 12 Enclosure

Liebert LM Series TVSS

Technical Specification

Maximum Continuous
Operating Voltage (MCOV)
...................... 120V 125%, all others 115%
Fault Current Rating (AIC) ....................... 200 kAIC
Operating Frequency Range ................... 47 – 63 Hz
Response Time ........................................ <0.5 ns
Operating Humidity.................................. 0% to 95%
Status Indication ...................................... LEDs, Audible Alarm, Dry Contacts
Certifications ............................................ UL 1449 & 1283, CUL, NEMA LS1,
ISO 9001:2000
Enclosure ................................................ NEMA 12
Warranty ................................................... 5 Years Parts

UL 1449 second edition clamping data

Configuration

L-N

L-G

L-L

N-G

120S, 120Y

400

400

700

400

240D

X

700

700

X

346Y

1200

1200

2000

1200

230Y, 277Y

700

700

1500

700

480D

X

1500

1500

X

600D

X

1800

2000

X

Job Name ____________________________

Model# ______________________________

Date ________________________________

Qty _________________________________

Quote# ______________________________

Source Configuration

1 Phase, L-N, 2W+G

N

1 Phase, L-L, 2W+G

L

Split Phase, 3W+G

S

3 Phase, WYE, 4W+G

Y

3 Phase, WYE, 3W+G

(No Neutral)

X

3 Phase, Delta, 3W+G

D

3 Phase, Delta Hi-leg, 4W+G

H

Surge Rating

60kA /
mode

060

80kA /
mode

080

100kA /
mode

100

125kA /
mode

125

150kA /
mode

150

200kA /
mode

200

225kA /
mode

225

250kA /
mode

250

Model # LM

__ __ __ __ __ __ __ __ __ __ __

Modes of Protection

All

A

L-G Voltage

120V

120

208V

208

220V

230

230V

230

240V

240

277V

277

480V

480

600V

600

Connection Options

Wire Lug

N

Disconnect

R

Enclosure

NEMA 12

(Standard)

E

NEMA 3R

R

NEMA 4

T

NEMA 4X

X

Monitoring Options

Standard Monitoring System,
LEDs, Audible Alarm,
Dual Form C Contacts

S

LEDs, Audible Alarm,
Surge Counter,
Dual Form C Contacts

C

Dimensional data in inches and shipping weight in pounds

Unit

Options

A

B

C

D

E

F

G

Wt.

LM060
LM080

All

16

14

8

16.75

12

0.31

1.35

32

LM100
LM125
LM150

All

16

14

8

16.75

12

0.31

1.84

41

LM200
LM225
LM250

All

20

16

9

21.25

10

0.44

1.84

56

Life Cycle Surge Testing

10kA, 20kV, IEEE Cat. C3

Unit

Per Mode

Per Phase

060-080

8,000

16,000

100-150

16,000

32,000

200-250

24,000

48,000

EMI/RFI Noise Rejection

Single

Unit

Frequency

System

Installation

34dB

100kHz

51dB

51dB

1MHz

94dB

54dB

10MHz

114dB

48dB

100MHz

120dB

E

D

C

B

G

A

F

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.