Liebert DPN002400 - Manual
Liebert DPN002400 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – MODEL; Liebert DCP
- Page 3 – Unit Piping Outlet Connection Sizes, inches, Od Cu; Pipe Connection Point
- Page 5 – Liebert DCP Extra Low Voltage field connection points; TO REMOTE T/H SENSOR A; TO OPTIONAL
STANDARD FEATURES
HEAT EXCHANGER - Brazed plate desi gn wi th i nterwoven circuiting constr ucted of stainless steel plates, copper br azed.
PU MPS - Centrifugal type.
ST ANDARD CONTROL PROCESSOR -
The standard control system is m icroprocessor-based with an exter nal LCD numerical display to allow
observation of speci fi ed settable functions. Normal operating condi ti ons are indi cated on the LCD display panel,
which is mounted to the unit. The control system al so monitors unit oper ation and activates an alarm when any
of the specified factory preset conditions are exceeded.
CABINET A ND FRAME -
C ustom powder painted steel panels. A hi nged control access panel opens to a second front panel, which i s a
protected enclosure for all high voltage components. Fram e is constructed of 14 gauge heli -arc welded tubul ar steel
and painted usi ng an auto- depositi on coating system.
Liebert DCP
Page 1/5
DPN002400
REV DATE 11/11
REV 0
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
Unit Dimensional Data Unit Base D Unit Base E F Height of Unit C Side Panel Overall A Overall B Floor Cutout Dimensions The shaded area indicates a recommended clearance of 36" (914mm) be provided for component access. * Dimension Does Not Include the Bezel of the Disconnect Switch.** Represent ...
MODEL 50/60 HZ DCP200 Unit Piping Outlet Connection Sizes, inches, Od Cu Pipe Connection Point 2-5/8 2-5/8 2-5/8 2-5/8 A B C D REV 0 PAGE 4/6 REV DATE 05/11 Liebert DCP Bottom View Drip Tray Dimensions 7.2” 3.1” 19.5” 3.9” 3.8” 6.5” 34” 37” SECONDARY IN BCW OUT BCW IN SECONDARY OUT Liebert DCP Page ...
Liebert DCP Extra Low Voltage field connection points NOTES: 1. CONTROL WIRING MUST BE CLASS 2 AND INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE (NEC). 2. REQUIRES SHIELDED CABLE. K11COM COMMON WARNING OUTPUT K11NO K11NC K11 TO REMOTE ALARM CIRCUIT BY OTHERS K11 N.O. CONTACT BY OTHERS FO...