Liebert DPN001599 REV 12/11 - Manual

Liebert DPN001599 REV 12/11

Liebert DPN001599 REV 12/11 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
Page: / 6

Table of Contents:

  • Page 2 – LIEBERT XD CHILLER (XDC) WITH iCOM CONTROLS; UNIT DIMENSIONAL DATA; MODEL
  • Page 3 – inches
  • Page 4 – LIEBERT XDC; LIEBERT; RETURN
  • Page 6 – Liebert XDC Extra Low Voltage field connection points
Loading the manual

REFER TO SL-16655, LIEBERT XTREME DENSITY SYSTEM DESIGN MANUAL, AND SL-16674, LIEBERT XDC USER MANUAL FOR ADDITIONAL DETAIL.

DPN001599

REV 12/11
REV 4

LIEBERT XD CHILLER (XDC) WITH iCOM CONTROLS

PAGE 1/6

STA ND AR D FEATU R ES

TANDEM COMPR ESSORS -

Scro ll with a sucti on g as coole d motor, vibr ation isola tors, the rma l over loa ds, man ua l re set high-pre ssure sw itch and pu mp

down low-p ressure swi tch .

REFRIGERATION SYSTEM -

Dua l R-407C r efrig er atio n circuits e ach i nclu din g liqui d line filter dryer s, r efriger an t sight glass wi th moisture in di cator ,

el ectro nic control va lve, ad justa ble exter na lly e qu al ized expa nsion va lves and liq ui d lin e sol enoid valves.

HEAT EXCHANGER -

Braze d pl ate d esign with interwoven circuiti ng co nstru cte d o f stain le ss steel pl ates, copper bra zed.

PU MPS -

Centrifugal type . Uses R-134a .

ST ANDARD CONTROL PROCESSOR

-

Th e standard co ntrol system is m icroprocessor-base d with an exter na l LCD nume rica l disp lay to allow

obser vation of spe ci fi ed se tta ble functions. Nor mal o pe rating condi ti ons are in di cated o n the LCD displa y panel, wh ich is mo un ted to th e unit. Th e con trol
system al so monitor s u nit op er atio n and activa tes an a larm whe n a ny of the specifie d factor y p reset condition s are excee de d.

CABINET A ND FRAME

-

C ustom powd er p ain ted steel pane ls. A hi nged contro l access panel op en s to a second front panel, wh ich i s a p ro tected

enclosure fo r all h igh voltage co mponents. Fram e is constr ucted o f 1 4 g au ge heli -ar c welded tubul ar steel an d pain ted u si ng a n a uto- de po siti on co ating
system.

CANBU S ISOLATOR

-

Electrically isola tes exter na l CAN BUS fr om in ternal CANBUS. Al lows for g re ater to ta l length o f e xternal CANBUS cables.


"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - LIEBERT XD CHILLER (XDC) WITH iCOM CONTROLS; UNIT DIMENSIONAL DATA; MODEL

REFER TO SL-16655, LIEBERT XTREME DENSITY SYSTEM DESIGN MANUAL, AND SL-16674, LIEBERT XDC USER MANUAL FOR ADDITIONAL DETAIL. DPN001599 REV 12/11REV 4 LIEBERT XD CHILLER (XDC) WITH iCOM CONTROLS PAGE 2/6 B Overall F Height of Unit A Overall SHADED AREAS INDICATE A RECOMMENDED CLEARANCE OF 36in (914mm...

Page 3 - inches

REFER TO SL-16655, LIEBERT XTREME DENSITY SYSTEM DESIGN MANUAL, AND SL-16674, LIEBERT XDC USER MANUAL FOR ADDITIONAL DETAIL. DPN001599 REV 12/11REV 4 LIEBERT XD CHILLER (XDC) WITH iCOM CONTROLS PAGE 3/6 DIMENSIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. 44in 1118 mm ~ 47in 1194 mm 6in 152 mm 23in 584 ...

Page 4 - LIEBERT XDC; LIEBERT; RETURN

REFER TO SL-16655, LIEBERT XTREME DENSITY SYSTEM DESIGN MANUAL, AND SL-16674, LIEBERT XDC USER MANUAL FOR ADDITIONAL DETAIL. DPN001599 REV 12/11REV 4 LIEBERT XD CHILLER (XDC) WITH iCOM CONTROLS PAGE 4/6 LIEBERT XDC RETURN SUPPLY LIEBERT XD COOLING MODULE Install Replaceable Filter Drier Assemblyin l...

Other Liebert Models