Page 2 – IMPORTANT SAFETY INSTRUCTIONS; SAVE THESE INSTRUCTIONS
Page 3 – GENERAL INSTALLATION; Or
Page 4 – AUDIBLE ALARM CONDITIONS; CONDITION
Page 5 – MAJOR COMPONENTS; BACK; Output; Continuous
Page 6 – MAINTENANCE; FUSE REPLACEMENT PROCEDURES; Fuse Type
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
Page 2 - IMPORTANT SAFETY INSTRUCTIONS; SAVE THESE INSTRUCTIONS
2 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important safety instructions that should be followed duringthe installation and maintenance of the UPS and batteries. Please read thismanual thoroughly before attempting to install or operate this UPS. WARNING: § To preven...
Page 3 - GENERAL INSTALLATION; Or
3 GENERAL INSTALLATION 32 - 104 F 0 - 40 C 4 inches110 mm R Remove from box Check for damage Plug in loads Plug UPS into AC / Mains Press On button R Or
Page 4 - AUDIBLE ALARM CONDITIONS; CONDITION
4 INTRODUCTION & SYSTEM DESCRIPTION Congratulations on your choice of the Liebert PowerSure ProActiveUninterruptible Power System (UPS). It provides conditioned power tomicrocomputers and other sensitive electronic equipment. The PowerSure ProActive is a compact, “Automatic Voltage Regulation” U...
Page 5 - MAJOR COMPONENTS; BACK; Output; Continuous
5 MAJOR COMPONENTS R BACK FRONT AC / Mains Battery Mode ON / Standby UPS Test DB-9 Interfacefor SiteNetMultiLink cable Output Receptacles AC Input /Fuse Holder Phone / Fax / Modem / Network Interface Alarm Silence ! Overload Fault Continuous Flashing
Page 6 - MAINTENANCE; FUSE REPLACEMENT PROCEDURES; Fuse Type
6 MAINTENANCE The PowerSure ProActive UPS requires very little maintenance. The batteriesare valve regulated, nonspillable, lead acid, and require that they be keptcharged to obtain their designed life. When ON, the UPS continuously chargesthe batteries when connected to the utility supply. When sto...
7 COMMUNICATIONS You can use SiteNet® MultiLink™ to allow your UPS to communicate toyour computer via your DB-9 communications port. Download MultiLinkfrom our web site at www.liebert.com . Pin Configuration Pin # Function 9 On Battery (N.O.) 8 On Battery (Common) 6 On Battery (N.C.) 1 Low Battery 7...
Page 10 - LIMITED WARRANTY
10 LIMITED WARRANTY Liebert Corporation extends the following LIMITED WARRANTY to the purchaserand to its customer (collectively referred to as the "Purchaser"): the enclosedUninterruptible Power System (UPS) and components are free from defects inmaterials and workmanship under normal use, ...
Page 11 - Technical Support; OWER
11 Technical Support U.S.A. 1-800-222-5877 Outside the U.S.A. 614-841-6755 U.K. +44 (0) 1793 553355 France +33 (0) 1 43 60 01 77 Germany +49 89 99 19 220 Italy +39 2 98250 1 Netherlands +00 31 475 503333 E-mail [email protected] W eb site http://www.liebert.com W orldwide FAX tech support +614-841...