Page 3 - Contents; iii
Contents Safety information . . . . . . . . . . iii Chapter 1. General information . . . . . 1 Introduction . . . . . . . . . . . . . . . . . 1 Server documentation . . . . . . . . . . . . . 2 Chapter 2. Server setup road map . . . 5 Chapter 3. Product overview . . . . . . 7 Server package . . . . ....
Page 4 - ii
Installing or removing the ThinkServer RAID100 or RAID 300 upgrade key for AdvancedRAID . . . . . . . . . . . . . . . . . 112 Installing or removing the ThinkServerManagement Module Premium . . . . . . 116 Installing or removing the ThinkServer TrustedPlatform Module . . . . . . . . . . . . 119 Inst...
Page 5 - Safety information; documentation DVD that comes with the product.; 제품을 사용하기 전에 제품과 함께 제공되는 문서 DVD의 다국어 안전 지침을 주의 깊게 읽어보십시오.
Safety information Note: Before using the product, be sure to read and understand the multilingual safety instructions on the documentation DVD that comes with the product. Antes de usar o produto, leia e entenda as instruções de segurança multilíngues no DVD de documentaçãoque o acompanha. Преди да...
Page 6 - iv
Przed skorzystaniem z produktu należy zapoznać się z wielojęzycznymi instrukcjami bezpieczeństwaznajdującymi się na płycie DVD z dokumentacją dostarczoną wraz z produktem. Antes de utilizar o produto, leia atentamente as instruções de segurança multilingues que constam noDVD de documentação fornecid...
Page 11 - ix
Statement 16 CAUTION:To reduce the risk of electric shock or energy hazards: • This equipment must be installed by trained service personnel in a restricted-access location, as defined by your local electrical code and the latest edition of IEC 60950. • Connect the equipment to a reliably earthed sa...
Page 13 - Chapter 1. General information; Introduction; ThinkServer EasyStartup
Chapter 1. General information This chapter provides some general information about your product. This chapter contains the following items: • “Introduction” on page 1 • “Server documentation” on page 2 Introduction This user guide for your Lenovo ® ThinkServer ® product contains information about t...
Page 14 - Server documentation; Printed document; Read Me First; Documentation DVD; Windows
Record information about your server in the following table. You will need the information if you ever needto have your server serviced. For where to find the product information label on the chassis, see “Machine type, model, and serial numberlabel” on page 13. Product name ________________________...
Page 17 - Chapter 2. Server setup road map
Chapter 2. Server setup road map This chapter provides a general road map to guide you through setting up your server. The server setup procedure varies depending on the configuration of the server when it was delivered. Insome cases, the server is fully configured and you just need to connect the s...
Page 19 - Chapter 3. Product overview; Server package; Features
Chapter 3. Product overview This chapter provides information about the server package, features, specifications, software programs,and component locations. This chapter contains the following items: • “Server package” on page 7 • “Features” on page 7 • “Specifications” on page 12 • “Software” on pa...
Page 21 - Expansion slots; • One serial connector on the rear panel; Video subsystem; Your server has the following RAS features:
Note: The term “2.5-inch hot-swap hard disk drives” or “2.5-inch hard disk drives” hereinafter refers to all the supported types of 2.5-inch hard disk drives, including the solid-state drives. • Optical drive – Up to two 5.25-inch SATA optical drives – The server has two optical drive bays. The lowe...
Page 22 - ThinkServer Management Module User Guide
• Security features – Server locks (see “Server locks” on page 25) – Administrator password and user password to help protect unauthorized access to the server (see “Using passwords” on page 65) – ThinkServer Trusted Platform Module (TPM), which is a security chip, to help enhance server security No...
Page 23 - Advanced system management features; ThinkServer Management Module
For more information about the LEDs for your server, refer to the related topics in “Locations” onpage 13. – Software programs For more information about the software programs, see “Software” on page 12. – Wake on LAN When the Wake on LAN feature is enabled on a computer that is connected to a local...
Page 24 - Specifications; This topic lists the physical specifications for your server.; Software; ThinkServer EasyUpdate Firmware Updater
Specifications This topic lists the physical specifications for your server. Dimensions Width: 195 mm (7.68 inches) Height: 430 mm (16.93 inches) without foot stands; 445 mm (17.52 inches) with foot stands Depth: 595 mm (23.43 inches) including the front bezel Weight The product weight varies depend...
Page 27 - Front view of the server; The following illustration shows the front view of the server.; Front panel
Front view of the server This topic provides information to help you locate the parts on the front of the server. The following illustration shows the front view of the server. CPU MEM PSU 1 2 Figure 3. Front view of the server 1 Front panel 6 Front door 2 Optical drive bay 2 (with an optical drive ...
Page 28 - Use the front door handle to open the front door.
3 Optical drive bay 1 Your server comes with an optical drive installed in the 5.25-inch optical drive bay 1. 4 Optical drive eject/close button Press this button to eject or close the optical drive when the server power is on. 5 Optical drive status LED The optical drive status LED is blinking in g...
Page 29 - Power switch with power status LED
Front panel This topic provides information to help you locate the control, connectors, and LEDs on the front panel ofthe server. The following illustration shows the control, connectors, and LEDs on the front panel of the server. Note: Depending on the model, your server might look slightly differe...
Page 31 - Front USB connector 1; Intelligent diagnostics module; The IDM is only available in some models.
Potential system error (system error LED: amber) Solution A power cord has been disconnected or a redundantpower supply has been removed. 1. Ensure that the power supplies are installed securely. 2. Ensure that the power cords are connected securely to the power supplies. 3. Install a new power supp...
Page 33 - Rear view of the server
LED Status Description Action Solid off The system fans are operatingcorrectly. 3 System fan error LED Solid on (amber) One or more system fans arerunning at low speed or havebeen removed. Check the BMC for errors andrun the diagnostic programs. See“Using a diagnostic program” onpage 189. Note: To i...
Page 35 - on the rear of the server. For each hot-swap redundant power; Power cord connectors; Used to connect the power cords.; Serial connector; Used to attach a device that uses a 9-pin serial connector.; USB connectors
Your server model might have one or two hot-swap redundant power supplies. Each hot-swap redundantpower supply has one power cord connector 1 on the rear of the server. For each hot-swap redundant power supply, there might be one or two status LEDs on the power supply near the power cord connector. ...
Page 36 - Used to attach a VGA-compatible video device, such as a VGA monitor.; ID LED
4 5 Ethernet connectors (RJ-45) Used to attach an Ethernet cable for a LAN. Each Ethernet connector has two status LEDs to help youidentify the Ethernet connectivity, activity, and connection speed. Note: The Ethernet connector 1 (callout 4 ) marked with “MGMT” is for system management. If you want ...
Page 37 - Expansion card area; to avoid thermal problems. See “System board components” on page 48.; Front door key; Used to open or lock the front door.; Server locks
8 Expansion card area You server has six expansion slots on the system board for you to install appropriate PCI cards or PCIExpress cards. For detailed information, see “System board components” on page 48. Note: If a ThinkServer Host Bus Adapter is available, refer to its user guide and the table b...
Page 38 - Padlock
Padlock Your server comes with a padlock loop. When a padlock is installed, the server cover cannot be removed. Figure 9. Padlock 26 ThinkServer TD340 User Guide and Hardware Maintenance Manual
Page 40 - Front door lock; Server components
Front door lock You can remove the key attached on the rear of the server and use it to open or lock the front door of theserver. The front door protects the hard-disk-drive cages and prevents unauthorized access to the installedhard disk drives. Figure 11. Front door lock Server components This top...
Page 44 - CRU identification; Non-CRUs must be replaced only by trained service technicians.
1 Heat sink and fan assembly 2 11 Hard disk drive bay 0 2 CPU1 DIMMs (vary by model) 12 Front system fan 1 3 Heat sink and fan assembly 1 13 Front system fan 2 4 Intelligent Diagnostics Module (available in some models) 14 System board 5 Front panel 15 System board battery 6 Optical drive bay 2 (wit...
Page 45 - Hot-swap hard disk drive status LEDs
Description Self-service CRU Optional-serviceCRU Peripheral Component Interconnect (PCI) card (available in some models) Yes No Power distribution board and cage assembly (available in models withhot-swap redundant power supplies) No Yes Rear system fan Yes No System board No No System board battery...
Page 47 - RAID card
Figure 16. 2.5-inch hot-swap hard disk drive status LEDs 1 Hard disk drive activity LED 2 Hard disk drive RAID status LED Description Off Off The hard disk drive has failed or isnot present. On, green Off The hard disk drive is present but notin use. Blinking, green Off The hard disk drive is active...
Page 48 - ThinkServer RAID 500 Upgrade Key for Advanced RAID connector
Some server models come with a required RAID card to provide advanced SATA/SAS hardware RAIDfunctions. If your server does not come with a RAID card, you can purchase one from Lenovo. Note: The option kit for the RAID card is designed for different types of servers and might contain additional cable...
Page 49 - External connector
4 External connector Used to attach the cable that connects a RAID card to the system board hard disk drive LED connector. See“Connecting the cables” on page 43. ThinkServer RAID 700 Adapter (also known as ThinkServer 9260-8i SAS RAID Adapter) The following illustration shows the connectors on the T...
Page 50 - ThinkServer RAID 710 Adapter (also known as 9270CV-8i RAID adapter); Expander card
ThinkServer RAID 710 Adapter (also known as 9270CV-8i RAID adapter) The following illustration shows the connectors on the ThinkServer RAID 710 Adapter. Figure 19. ThinkServer RAID 710 Adapter 1 Port 1 2 Port 2 1 Port 1 2 Port 2 Used to connect a mini-SAS signal cable. See “Connecting the cables” on...
Page 52 - SAS hard disk drives with two backplanes
The following illustration shows the locations of the hot-swap hard-disk-drive backplanes. You need to openthe server cover and remove the front system fans to access the backplanes. See “Removing the servercover” on page 85 and “Replacing the front system fan 1” on page 168. Notes: 1. Depending on ...
Page 53 - -pin power connector
The following illustrations show the connectors on a 3.5-inch hot-swap hard-disk-drive backplane. Figure 22. Front view of the 3.5-inch hot-swap hard-disk-drive backplane 1 Slot 0 for a 3.5-inch SATA or SAS hot-swap hard disk drive 3 Slot 2 for a 3.5-inch SATA or SAS hot-swap hard disk drive 2 Slot ...
Page 54 - Used to connect the P5 power connector of the power supply.
2.5-inch hot-swap hard-disk-drive backplane This topic provides information to help you locate the connectors on the 2.5-inch hot-swap hard-disk-drivebackplane. The following illustrations show the connectors on the 2.5-inch hot-swap hard-disk-drive backplane. Figure 24. Front view of the 2.5-inch h...
Page 55 - Connecting the cables; b. Connect the four SATA ports
2 Mini-SAS signal cable connector 1 Used to connect the mini-SAS connector on one end of the mini-SAS signal cable. 3 Mini-SAS signal cable connector 0 Used to connect the mini-SAS connector on one end of the mini-SAS signal cable. Connecting the cables This topic provides instructions on the follow...
Page 60 - System board components
The following table provides information about the recommended power connector and system board SATAconnector for the non-hot-swap hard disk drive installed in each drive bay. See “Server components” onpage 28 and “System board components” on page 48 for the location information about the hard disk ...
Page 62 - Used to connect the heat sink and fan assembly 1 cable.
7 Power Management Bus (PMBus) connector The ThinkServer Management Module can read the power supply status registered through PMBus. You donot need to connect any device to the PMBus connector. This connector is kept for power management inmodels with redundant power supplies. The function of the P...
Page 64 - System board jumpers and switches
36 ThinkServer Management Module With the integrated ThinkServer Management Module (hereinafter referred to as the TMM), no matter whatcondition the server operating system is in and no matter if the server is on or off, as long as the serveris connected to network and an ac power source, the intera...
Page 65 - ThinkServer Management Module Enable/Disable jumper
The following illustration shows the status of the jumpers and switches on the system board of your server.You can configure, recover, enable, or disable some specific features of the system board by setting thejumpers or moving the switches. Figure 31. System board jumpers and switches Table 2. Sys...
Page 66 - Clear CMOS jumper; Rack Installation Instructions
2 Clear CMOS jumper Used to clear CMOS and recover your server to the factory default settings. Note: After clearing CMOS, your BIOS recovers to the factory default settings. To clear CMOS, do the following: 1. Remove all media from the drives and turn off all attached devices and the server. Then, ...
Page 67 - Switches; There are four switches on the system board of your server.; BIOS recovery switch
3 Switches There are four switches on the system board of your server. Figure 32. Switches Table 3. Switches 1 BIOS recovery switch 3 Management Engine (ME) in force update switch 2 Clear password switch 4 Reserved for the manufacturer 1 BIOS recovery switch Used to recover the BIOS if the power to ...
Page 68 - ME in force update switch; System board LEDs
2. If the server is installed in a rack cabinet, remove the server from the rack cabinet and place it on a flat, clean, and static-protective surface. See the Rack Installation Instructions that comes with the server. 3. Remove the server cover. See “Removing the server cover” on page 85. 4. Locate ...
Page 69 - System fan error LEDs
turned on. Many errors are first indicated by a lit error LED on the diagnostic panel of the server. If an LED islit, one or more LEDs elsewhere in the server might also be lit to direct you to the source of the error. The following illustration shows the ThinkServer Management Module status LED and...
Page 70 - ThinkServer Management Module status LED
6 ThinkServer Management Module status LED This LED indicates the ThinkServer Management Module (TMM) status of your server. ThinkServer Management Module status LED Color Description On Green The TMM is not ready. Off None The TMM has no power or has failed. Blinking Green The TMM is working. 58 Th...
Page 71 - Chapter 4. Turning on and turning off the server; Turning on the server; Turning off the server
Chapter 4. Turning on and turning off the server This chapter provides information about turning on and turning off the server. Turning on the server The server can be turned on in one of the following ways: • After you finish unpacking and setting up the server, connect it to an ac power source. Pr...
Page 72 - for the operating system.
• The server might be turned off as an automatic response to a critical system failure. Notes: 1. When you turn off the server and leave it connected to an ac power source, the server also can respond to a remote request to turn on the server. To remove all power from the server, you must disconnect...
Page 73 - Chapter 5. Configuring the server; Using the Setup Utility program; Main
Chapter 5. Configuring the server This chapter provides the following information to help you configure the server: • “Using the Setup Utility program” on page 61 • “Using the ThinkServer EasyStartup program” on page 69 • “Configuring RAID” on page 72 • “Configuring the Ethernet controllers” on page...
Page 74 - Setup Utility program interface; Main menu
– Select SATA/SAS Configuration and follow the instructions on the screen to view information about the installed SATA or SAS devices, such as a hard disk drive or an optical drive. • On the Server Management menu, select System Information to view information about your system. Setup Utility progra...
Page 76 - Setting the system date and time
• BMC Status : View the BMC status. • Erase SEL : Erase system event log (SEL). • System Information : View basic information about your server. • BMC Network Configuration : Set BMC configuration parameters. Boot Options menu The Boot Options menu in the Setup Utility program provides an interface ...
Page 77 - Using passwords; Setup Utility program password types; Administrator password; Password considerations
3. Use the Tab key to switch between data elements and type the numbers from the keyboard to set the system date and time. 4. Press F10 to save settings and exit the Setup Utility program. Using passwords By using the Setup Utility program, you can set a password to prevent unauthorized access to yo...
Page 79 - Exiting the Setup Utility program; Save Changes and Exit; Updating or recovering the BIOS; Save as User Defaults
4. Press F10 to save settings and exit the Setup Utility program. The server will restart to enable the TPM function. Exiting the Setup Utility program After you finish viewing or changing settings, press Esc to return to the Setup Utility program main interface.If you are on a nested submenu, press...
Page 80 - Defaults; Recovering from a BIOS update failure
Defaults on the Save & Exit menu in the Setup Utility program to restore the user default values after updating the BIOS. In this case, you can keep your previous BIOS settings and do not need to reconfigurethe settings after updating the BIOS. You also can record your specific BIOS settings bef...
Page 81 - Using the ThinkServer EasyStartup program; Features of the ThinkServer EasyStartup program; Starting the ThinkServer EasyStartup program; User Guide
Using the ThinkServer EasyStartup program This topic provides instructions on how to use the ThinkServer EasyStartup program to set up and configureyour server. The ThinkServer EasyStartup program simplifies the process of configuring RAID and installing supportedWindows and Linux operating systems ...
Page 85 - Configuring RAID using the ThinkServer EasyStartup program
• RAID 5 : block-level striping with distributed parity RAID 5 uses disk striping and parity data across all drives (distributed parity) to provide high datathroughput, especially for small random access. RAID 5 distributes parity along with the data and requiresall drives but one to be present to o...
Page 86 - Configuring the ThinkServer RAID 100 or RAID 300; RAID array status; The RAID array status can be one of the following:; Online; Starting the LSI Software RAID Configuration Utility program
insert the ThinkServer EasyStartup DVD into the optical drive. The installation packages for the programs are located in the Utilities and Others folder in the root directory of the DVD. The ThinkServer EasyStartup DVD is designed for different types of servers and the Utilities and Others folder mi...
Page 88 - Creating, adding, or deleting a RAID array
Table 4. LSI Software RAID Configuration Utility program menu items (continued) Menu item Submenu item Comments Adapter Set adapter-related parameters, suchas rebuild rate, consistency check rate,and so on. Virtual Drive Set virtual drive parameters. Objects Physical Drive Set physical drive paramet...
Page 89 - Initializing a virtual drive; Initialize; Setting a hot-spare drive; MegaRAID SAS Software User Guide; Objects; Rebuilding a physical drive
Initializing a virtual drive This topic provides instructions on how to initialize a virtual drive using the LSI Software RAID ConfigurationUtility program after completing the configuration process. Virtual drive initialization is the process of writing zeros to the data fields of a virtual drive a...
Page 90 - Rebuild; Running a consistency check; Check Consistency
detailed information about disk rebuild, refer to “Introduction to RAID” in the MegaRAID SAS Software User Guide on the documentation DVD that comes with your server. To rebuild a physical drive using the LSI Software RAID Configuration Utility program when a physical drivein a RAID array fails, do ...
Page 91 - Installing and using the MegaRAID Storage Manager program; Configuring the advanced SATA/SAS hardware RAID
Note: Using a consistency check rate of 0 or 100 percent is not recommended. The default value is 30 percent. 1. Start the LSI Software RAID Configuration Utility program. See “Starting the LSI Software RAID Configuration Utility program” on page 74. 2. On the main interface of the program, select O...
Page 92 - Configuring the Ethernet controllers; without encountering hardware problems.; Using the Lenovo ThinkServer EasyManage program
For instructions on how to configure and manage the advanced SATA/SAS hardware RAID, refer to the MegaRAID SAS Software User Guide on the documentation DVD that comes with your server. This document also is available on the Lenovo Web site at:http://www.lenovo.com/UserManuals Configuring the Etherne...
Page 96 - Handling static-sensitive devices; • Do not place the part on the server cover or other metal surface.
• Back up all important data before you make changes to drives. • Have a small flat-blade screwdriver available. • You do not have to turn off the server to install or replace a hot-swap redundant power supply, a hot-swap hard disk drive, or a hot-plug USB device. However, you must turn off the serv...
Page 97 - – Use the ground prong of the ac plug on ac-operated servers.; System reliability guidelines; • Ensure that you replace a failing fan within 48 hours.; Working inside the server with the power on; • Do not allow your necktie or scarf to hang inside the server.; Removing the server cover
Note: The use of a grounding system to guard against ESD damage is desirable but not necessary. – Attach the ESD ground clip to any frame ground, ground braid, or green-wire ground. – When working on a double-insulated or battery-operated system, use an ESD common ground or reference point. You can ...
Page 99 - Pivot the server cover outward to completely remove it.; Removing and reinstalling the front bezel; To remove and reinstall the front bezel, do the following:
6. Pivot the server cover outward to completely remove it. Figure 35. Removing the server cover Attention: For proper cooling and airflow, install the server cover before turning on the server. Operating the server for more than 30 minutes with the server cover removed might damage server components...
Page 101 - Go to “Completing the parts replacement” on page 185.; Removing and reinstalling the PCI card bracket assembly; Remove the server cover. See “Removing the server cover” on page 85.
4. To reinstall the front bezel, align the other three plastic tabs on the right side of the front bezel with the corresponding holes in the chassis, then pivot the front bezel inward until it snaps into positionon the left side. Figure 37. Installing the front bezel 5. Go to “Completing the parts r...
Page 104 - Go to “Completing the parts replacement” on page 185.; Installing, removing, or replacing hardware
b. Place the PCI card bracket assembly into the chassis so that the two mounting studs 2 on the bottom of the chassis are inserted into the corresponding holes in the PCI card bracket assembly.Ensure that the edge of the RAID card can be smoothly inserted into the slot 1 in the small low-profile PCI...
Page 105 - Installing or removing a memory module; Memory module installation rules
Installing or removing a memory module This topic provides instructions on how to install or remove a memory module. Note: The memory modules are sensitive to ESD. Ensure that you read and understand “Handling static-sensitive devices” on page 84 first and carefully perform the operation. Memory mod...
Page 108 - Memory module installation order in independent mode; Memory module installation order in mirroring mode; • In this mode, slots A1 and A2 cannot be populated.
Memory module installation order in independent mode This section explains the memory module installation order in independent mode. In this mode, the RASfeatures are not available. For more information about the RAS features, refer to the related section in“Features” on page 7. Note: All memory mod...
Page 109 - Memory module installation order in sparing mode; • At least three ranks are available in one channel.; Memory module installation order in lockstep mode
Memory module installation order in sparing mode This section explains the memory module installation order in sparing mode. The sparing mode providesmemory redundancy. In this mode, the RAS features are available. For more information about the RASfeatures, refer to the related section in “Features...
Page 110 - Installing a memory module; the instructions in this topic.
The following table explains the memory module installation order for servers that have two microprocessors(CPU1 and CPU2) installed. Table 14. Memory module installation order in lockstep mode for servers with two microprocessors CPU1 DIMM CPU2 DIMM A1 A2 B1 B2 C1 C2 D1 D2 E1 E2 F1 F2 DIMM installa...
Page 111 - Removing a memory module
7. Touch the static-protective package that contains the new memory module to any unpainted surface on the outside of the server. Then, take the new memory module out of the package. Note: Carefully handle the memory module by its edges. 8. Position the new memory module over the memory slot. Ensure...
Page 112 - packaging materials that are supplied to you for shipping.; Installing or removing the Ethernet card; devices” on page 84 first and carefully perform the operation.; Installing the Ethernet card
5. Remove any parts or disconnect any cables that might prevent your access to the memory slots. 6. Locate the memory module that you want to remove and open the retaining clips on both ends of the memory slot. Then, grasp the memory module by its edges and carefully pull it straight up to remove it...
Page 113 - Carefully handle the Ethernet card by its edges.
• If your server has one microprocessor installed, the Ethernet card can be installed into the PCI-E slot 2 or PCI-E slot 6. If your server has two microprocessors installed, the Ethernet card can be installed into thePCI-E slot 2, PCI-E slot 3, PCI-E slot 4, PCI-E slot 5, or PCI-E slot 6. To instal...
Page 114 - reinstalling the PCI card bracket assembly” on page 89.
9. Position the new Ethernet card over the PCI Express card slot for which you have removed the slot bracket, and then carefully press the Ethernet card straight down until it is securely seated in the slot.Install the screw to secure the Ethernet card in place. Figure 50. Installing the Ethernet ca...
Page 115 - Removing the Ethernet card
The most up-to-date device drivers for various server models are always available for download on theLenovo Support Web site at:http://www.lenovo.com/drivers Removing the Ethernet card Attention: Do not open your server or attempt any repair before reading and understanding “Safety information” on p...
Page 116 - carefully pull it out of the PCI Express card slot.; place. See “Installing the Ethernet card” on page 100.; Installing or removing the RAID card
7. Remove the screw that secures the Ethernet card. Then, grasp the Ethernet card by its edges and carefully pull it out of the PCI Express card slot. Note: The Ethernet card fits tightly into the PCI Express card slot. If necessary, alternate moving each side of the Ethernet card a small and equal ...
Page 117 - Installing the RAID card
Installing the RAID card Attention: Do not open your server or attempt any repair before reading and understanding “Safety information” on page iii and “Guidelines” on page 83. This topic provides instructions on how to install the RAID card. Before you begin, print all the related instructions or e...
Page 118 - Removing the RAID card
version of the Firmware Updater program does not contain the latest version of the driver you need,download that driver separately from the Web page and install it individually to your server. Removing the RAID card Attention: Do not open your server or attempt any repair before reading and understa...
Page 119 - Installing the TR 500 Key
• To work with another piece of hardware, go to the appropriate section. • To complete the removal procedure, go to “Completing the parts replacement” on page 185. Then, you need to reconfigure RAID for your server. See “Configuring RAID” on page 72. Installing or removing the ThinkServer RAID 500 U...
Page 120 - MegaRAID SAS; Removing the TR 500 Key; system after removing the TR 500 Key.
6. Locate the TR 500 Key connector on the ThinkServer RAID 500 Adapter, and then insert the TR 500 Key into the connector. You might need to remove the ThinkServer RAID 500 Adapter first, install theTR 500 Key on it, and then reinstall the ThinkServer RAID 500 Adapter. See “Installing or removingthe...
Page 121 - MegaRAID; Installing or removing the ThinkServer RAID 700 Battery
To remove the TR 500 Key from the RAID card, do the following: 1. Remove all media from the drives and turn off all attached devices and the server. Then, disconnect all power cords from electrical outlets and disconnect all cables that are connected to the server. 2. Remove the server cover. See “R...
Page 122 - Installing the TR 700 Battery
alternative to using an uninterruptible power supply, and a second level of fault tolerance when used inconjunction with an uninterruptible power supply. The temperature of the TR 700 Battery is generally 15-20°C (59-68°F) higher than the ambient temperatureduring fast charge. Therefore, to complete...
Page 123 - Removing the TR 700 Battery
7. Position the TR 700 Battery above the ThinkServer RAID 700 Adapter so that the board-to-board connector 1 on the bottom of the TR 700 Battery is aligned with the connector 2 on the ThinkServer RAID 700 Adapter; and the three mounting studs on the bottom of the TR 700 Battery are aligned withthe c...
Page 125 - addition to the instructions in this topic.
for the onboard SATA or SAS software RAID correspondingly. You can purchase a TR 100 or TR 300 Keyfrom Lenovo and install it to the iButton socket on the system board. This topic provides instructions on how to install or remove the TR 100 or TR 300 Key. Installing the TR 100 or TR 300 Key Attention...
Page 128 - Installing the TMM Premium
What to do next: • To work with another piece of hardware, go to the appropriate section. • To complete the removal procedure, go to “Completing the parts replacement” on page 185. As the onboard SATA or SAS software RAID 5 is not available without the TR 100 or TR 300 Key, you might needto reconfig...
Page 129 - refer to the; Removing the TMM Premium
5. Locate the TMM Premium connector on the system board, and then insert the TMM Premium into the TMM Premium connector. Note: Ensure that the TMM Premium is securely seated on the system board. Figure 58. Installing the TMM Premium What to do next: • To work with another piece of hardware, go to th...
Page 131 - Installing or removing the ThinkServer Trusted Platform Module; Installing the ThinkServer Trusted Platform Module; This topic provides instructions on how to install the TPM.
Installing or removing the ThinkServer Trusted Platform Module This topic provides instructions on how to install or remove the ThinkServer Trusted Platform Module(hereinafter referred to as the TPM). The TPM is a security chip designed by the Trusted Computing Group (TCG) to provide a hardware meth...
Page 132 - Removing the ThinkServer Trusted Platform Module; • If you remove the TPM, the TPM function will be unavailable.
5. Locate the TPM connector on the system board, and then insert the TPM into the TPM connector. Figure 60. Installing the TPM What to do next: • To work with another piece of hardware, go to the appropriate section. • To complete the installation, go to “Completing the parts replacement” on page 18...
Page 133 - materials that are supplied to you for shipping.
• Depending on the model, your server might look slightly different from the illustration in this topic. To remove the TPM, do the following: 1. Remove all media from the drives and turn off all attached devices and the server. Then, disconnect all power cords from electrical outlets and disconnect ...
Page 134 - Installing or removing the intelligent diagnostics module; Installing the intelligent diagnostics module; This topic provides instructions on how to install the IDM.
Installing or removing the intelligent diagnostics module This topic provides instructions on how to install or remove the intelligent diagnostics module (hereinafterreferred to as the IDM). The IDM, which is only available in some models, provides diagnostic LEDs through the IDM panel to helpyou ea...
Page 135 - in the
6. Route the signal cable of the IDM through the corresponding hole in the chassis and position the IDM on the chassis so that the screw hole in the IDM is aligned with the corresponding screw hole 1 in the chassis. Then, install the screw to secure the IDM in place. Figure 62. Installing the IDM 7....
Page 136 - Removing the intelligent diagnostics module
8. Connect the other end of the signal cable to the IDM connector on the system board. See “System board components” on page 48. Then, properly route the signal cable of the IDM. You might need tosecure the signal cable with cable clips or ties in the chassis. Figure 63. Cable routing 9. Reinstall t...
Page 137 - Disconnect the signal cable from the rear of the IDM.
1. Remove all media from the drives and turn off all attached devices and the server. Then, disconnect all power cords from electrical outlets and disconnect all cables that are connected to the server. 2. Remove the server cover. See “Removing the server cover” on page 85. 3. Remove the front bezel...
Page 138 - Installing or replacing an optical drive; might result in hazardous radiation exposure.
Installing or replacing an optical drive Attention: Do not open your server or attempt any repair before reading and understanding “Safety information” on page iii and “Guidelines” on page 83. This topic provides instructions on how to install or replace an optical drive. The EMI integrity and cooli...
Page 141 - Connect the power cable; board. See “System board components” on page 48.
6. Slide the new optical drive into the drive bay from the front until it snaps into position. Note: You do not need to remove the front bezel when replacing an optical drive. However, if you are adding a secondary optical drive in the upper optical drive bay, you need to remove the front bezelfirst...
Page 142 - Installing or replacing a hot-swap hard disk drive; on page 28 to locate the hard disk drive bays in your server.
• If you are installing an optical drive, save the removed EMI-protective shield from the chassis and plastic shield from the front bezel in the event that you later remove the drive and need the shields tocover the drive bay. • If you are replacing an optical drive and are instructed to return the ...
Page 145 - Do not touch the circuit board on the hard disk drive.
4. Pull the handle and carefully slide the hot-swap hard disk drive or the dummy tray out of the front of the chassis. Figure 71. Removing the hot-swap hard disk drive or the dummy tray 5. Touch the static-protective package that contains the new hot-swap hard disk drive to any unpainted surface on ...
Page 146 - and then completely close the handle.; • To configure RAID, go to “Configuring RAID” on page 72.; Installing or removing a non-hot-swap hard disk drive
6. Slide the new hot-swap hard disk drive into the drive bay from the front until it snaps into position, and then completely close the handle. Figure 72. Installing the hot-swap hard disk drive 7. Check the hot-swap hard disk drive status LEDs to ensure that the hard disk drive is operating correct...
Page 147 - Installing a non-hot-swap hard disk drive
For a list of ThinkServer hard disk drive options, go to:http://www.lenovo.com/thinkserver The EMI integrity and cooling of the server are protected by having all drive bays covered or occupied. Thenumber of the installed hard disk drives in your server varies depending on the server model. The vaca...
Page 148 - Remove the server cover. See “Removing the server cover” on page 85.
2. Use the front door key to unlock the front door, and then use the front door handle 1 to pivot the front door to the open position. Figure 73. Opening the front door of the server 3. Remove the server cover. See “Removing the server cover” on page 85. 136 ThinkServer TD340 User Guide and Hardware...
Page 151 - pivot the EMI-protective panel down until it snaps into position.
13. Align the top edge of the EMI-protective panel with the top side of the hard-disk-drive cage, and then pivot the EMI-protective panel down until it snaps into position. Figure 77. Installing the EMI-protective panel 14. Close and lock the front door. What to do next: • To work with another piece...
Page 154 - the bracket for future use.
7. Insert two fingers into the holes in the two tabs on the front of the blue bracket. Then, press the tabs towards each other and carefully slide the non-hot-swap hard disk drive out of the front of the chassis. Figure 80. Sliding the non-hot-swap hard disk drive out of the bay 8. Flex the sides of...
Page 155 - save the cable for future use.; Installing or replacing the microprocessor; Installing the second microprocessor
10. Align the top edge of the EMI-protective panel with the top side of the hard-disk-drive cage, and then pivot the EMI-protective panel down until it snaps into position. Figure 81. Installing the EMI-protective panel 11. Disconnect the SATA cable for the removed non-hot-swap hard disk drive from ...
Page 157 - be kept as clean as possible.
5. Press down the small handle on the microprocessor socket, and then pull the handle a little bit outward to release it from the secured position. Then, gently press the microprocessor retainer to open it. Ensurethat the small handle and the microprocessor retainer are in the fully open position. F...
Page 159 - “Replacing the heat sink and fan assembly 1” on page 173.; Replacing the microprocessor
10. Gently close the microprocessor retainer, press down the small handle, and then push the handle inward to lock the retainer into position and secure the new microprocessor in the socket. Figure 86. Securing the microprocessor in the socket 11. Install the new heat sink and fan assembly that come...
Page 163 - Installing or replacing a hot-swap redundant power supply
10. Gently close the microprocessor retainer, press down the small handle, and then push the handle inward to lock the retainer into position and secure the new microprocessor in the socket. Figure 91. Securing the microprocessor in the socket 11. Reinstall the heat sink and fan assembly. See “Repla...
Page 164 - instructions in addition to the instructions in this topic.
Some server models come with only one power supply. You can purchase a hot-swap redundant powersupply option from Lenovo. CAUTION:Hazardous moving parts. Keep fingers and other body parts away. CAUTION:Never remove the cover on a power supply or any part that has the following label attached. Hazard...
Page 166 - it snaps into position.
2. If you are replacing a hot-swap redundant power supply, press the release tab 1 in the direction as shown and carefully pull the handle 2 at the same time to slide the failing hot-swap redundant power supply out of the chassis. Figure 93. Removing a hot-swap redundant power supply 3. Touch the st...
Page 167 - Replacing the non-hot-swap power supply assembly
5. Connect the power cord to the power cord connector on the new hot-swap redundant power supply. Then, check the status LED near the power cord connector. When the LED is lit in green, it indicatesthat the hot-swap redundant power supply is working correctly. When the LED is lit in amber, it indica...
Page 172 - Carefully handle the backplane by its edges.
• For the 2.5-inch hot-swap hard-disk-drive backplane, remove the six screws or three screws that secure the backplane depending on the type of the backplane. Then, remove the backplane from thehard-disk-drive cage. Figure 99. Removing the 2.5-inch hot-swap hard-disk-drive backplane 10. Touch the st...
Page 174 - Replacing the power distribution board and cage assembly
12. Slide the hard-disk-drive cage into the chassis from the front until it snaps into position. Note: The following illustration shows the 3.5-inch hard-disk-drive cage. For the 2.5-inch hard-disk-drive cage, the installation procedure is the same. Figure 103. Installing the hard-disk-drive cage 13...
Page 177 - Use only screws provided by Lenovo.; Replacing the front panel board assembly
10. Install the new power distribution board and cage assembly into the chassis so that the two screw holes in the rear of the new power distribution board and cage assembly are aligned with the correspondingholes marked with R in the rear of the chassis. Meanwhile, ensure that the two screw holes i...
Page 179 - assembly and connect them to the rear of the new one.
8. Remove the screw 1 on the chassis that secures the front panel board assembly. Then, carefully remove the front panel board assembly from the chassis and pull the signal cables of the front panelboard assembly out of the chassis. Figure 106. Removing the front panel board assembly 9. Touch the st...
Page 180 - use any packaging materials that are supplied to you for shipping.; Replacing the front system fan 1
11. Route the signal cables of the new front panel board assembly through the corresponding hole in the chassis and position the new front panel board assembly on the chassis so that the screw hole in itis aligned with the corresponding screw hole 1 in the chassis. Then, install the screw to secure ...
Page 182 - “System board components” on page 48.; Replacing the rear system fan
6. Touch the static-protective package that contains the new front system fan 1 to any unpainted surface on the outside of the server. Then, remove the new front system fan 1 from the package. 7. Position the new front system fan 1 on the system fan 1 mounting area of the chassis so that the three t...
Page 185 - Replacing the heat sink and fan assembly 1
7. Position the new rear system fan, which has four new rubber mounts attached, on the chassis so that the four new rubber mounts are aligned with the corresponding holes in the chassis. Push the rubbermounts through the holes, and then pull on the tips of the rubber mounts from the other side of th...
Page 188 - Replacing the system board battery
10. Install the four screws to secure the new heat sink and fan assembly 1 on the system board. It is recommended that you carefully install the four screws using the following method to avoid any possibledamage to the system board. a. Partially tighten screw 1 , then firmly tighten screw 3 , and th...
Page 190 - Ethernet card” on page 100.; Replacing the system board
6. Remove the old system board battery. Figure 114. Removing the system board battery 7. Install a new system board battery. Figure 115. Installing the system board battery 8. Reinstall the PCI Express card (such as the Ethernet card) that has been removed. See “Installing the Ethernet card” on page...
Page 192 - board following the recommended numerical sequence as shown.
13. Disconnect all cables from the system board. Then, remove the ten screws that secure the system board following the recommended numerical sequence as shown. Figure 116. Removing the screws that secure the system board 180 ThinkServer TD340 User Guide and Hardware Maintenance Manual
Page 193 - Carefully handle the system board by its edges.
14. Gently lift each edge of the system board a little bit upward so that the system board is released from the mounting studs on the chassis. Then, move the system board to the front of the server and thencarefully pivot the system board upward to remove it out of the chassis. Note: Carefully handl...
Page 195 - system board on the chassis.; “Installing or replacing the microprocessor” on page 143.
17. Install the ten screws following the recommended numerical sequence as shown to secure the new system board on the chassis. Figure 119. Installing the screws to secure the system board 18. Remove the microprocessors from the old system board and install them on the new system board. See “Install...
Page 196 - handle inward to lock the retainer into position.
b. Position the microprocessor socket cover above the microprocessor socket so that the small triangle 1 on the socket cover faces the small triangle 2 on the microprocessor retainer. Then, carefully press the socket cover straight down into the socket until it snaps into position. Figure 120. Insta...
Page 197 - • After a system board is replaced, do the following:; Completing the parts replacement; left inside your server.
What to do next: • To work with another piece of hardware, go to the appropriate section. • To complete the replacement, go to “Completing the parts replacement” on page 185. • After a system board is replaced, do the following: 1. Start the Setup Utility program by pressing the F1 key, and then che...
Page 199 - Updating the server configuration; ThinkServer
6. Tighten the thumbscrew on the server cover to secure the server cover in place. Note: For safety consideration, ensure that you use a tool, for example a screwdriver, to tighten the thumbscrew and always ensure that the thumbscrew is securely installed. Also, do not over-tightenthe thumbscrew. 7....
Page 201 - Chapter 7. Troubleshooting and diagnostics; Troubleshooting procedure; functioning electrical outlets.; Viewing the status and diagnostic LEDs; To use a diagnostic program, do the following:
Chapter 7. Troubleshooting and diagnostics This chapter provides information about basic troubleshooting and diagnostic methods to help you solveproblems that might occur in the server. If you cannot diagnose and correct a problem by using the information in this chapter, see Chapter 8“Getting infor...
Page 202 - to start the program.; Viewing the system event log; For more information about viewing the SEL, refer to the; Basic troubleshooting tables
1. Go to http://www.lenovo.com/drivers and follow the instructions on the Web page to locate a diagnostic program. 2. Download and unzip the diagnostic program package to get the diagnostic program package folder. 3. Open the diagnostic program package folder and run the QTW.exe file. 4. Select the ...
Page 203 - Optical drive problems
Symptom Action through the program main interface. See “Startingthe ThinkServer EasyStartup program” on page 69. 2. Verify if the optical drive or the disc has problems. See “Optical drive problems” on page 191. Optical drive problems Follow the suggested actions for the corresponding symptom in the...
Page 204 - Hard disk drive problems
Symptom Action 8. Replace the signal cable for the optical drive. 9. Replace the optical drive. Hard disk drive problems Follow the suggested actions for the corresponding symptom in the order in which they are listed until theproblem is solved. If none of these actions solve the problem, see “Troub...
Page 205 - Memory module problems
Symptom Action 8. Reconnect the backplane signal cable and repeat step 1 through step 4. 9. If you suspect a problem with the backplane signal cable or the backplane: a. Replace the affected backplane signal cable. b. Replace the affected backplane. Multiple hard disk drives fail. 1. If you have any...
Page 207 - User Guide and; ThinkServer Web site; • Purchase additional services and software.; Lenovo Support Web site
Chapter 8. Getting information, help, and service This chapter contains information about help, service, and technical assistance for products manufacturedby Lenovo and where to go for additional information about Lenovo and Lenovo products. Information resources You can use the information in this ...
Page 208 - Problem determination
• Drivers and software • Diagnostic solutions • Product and service warranty • Product and parts details • User guides and manuals • Knowledge base and frequently asked questions Help and service This topic contains information about obtaining help and service. Before you call Before you call, do th...
Page 209 - Using other services; Warranty; the instructions on the screen.; Purchasing additional services
The warranty does not cover the following:• Replacement or use of parts not manufactured for or by Lenovo or non-warranted Lenovo parts• Identification of software problem sources• Configuration of the UEFI BIOS as part of an installation or upgrade• Changes, modifications, or upgrades to device dri...
Page 212 - Trademarks; Linux is a registered trademark of Linus Torvalds.; Important notes
Trademarks Lenovo, the Lenovo logo, and ThinkServer are trademarks of Lenovo in the United States, other countries, orboth. Intel, Intel Core, and Intel Xeon are trademarks of Intel Corporation in the United States, other countries, orboth. Linux is a registered trademark of Linus Torvalds. Microsof...
Page 213 - Polyvinyl Chloride (PVC) cable and cord notice; Wash hands after handling; Recycling information; Battery recycling information for the United States and Canada
or replacement of servers or parts on implementation of appropriate remedial measures to mitigate suchenvironmental contamination. Implementation of such remedial measures is a customer responsibility. Table 15. Limits for particulates and gases Contaminant Limits Particulate • The room air must be ...
Page 214 - Battery recycling information for the European Union; This mark applies only to countries within the European Union (EU).; Requirements for Batteries Containing Perchlorate; California Perchlorate Information:
Battery recycling information for the European Union Notice: This mark applies only to countries within the European Union (EU). Batteries or packaging for batteries are labeled in accordance with European Directive 2006/66/ECconcerning batteries and accumulators and waste batteries and accumulators...
Page 216 - Industry Canada Class A emission compliance statement; This Class A digital apparatus complies with Canadian ICES-003.; United Kingdom telecommunications safety requirement; Notice to Customers
Electronic emission notices The following information refers to the Lenovo ThinkServer machine types 70B4, 70B5, 70B6, and 70B7. Federal Communications Commission (FCC) Statement This equipment has been tested and found to comply with the limits for a Class A digital device, pursuantto Part 15 of th...
Page 217 - in which case the user may be required to take adequate measures.; German Class A compliance statement; Eurasian compliance mark
Warning: This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. German Class A compliance statement Deutschsprachiger EU Hinweis: Hinweis für Geräte der Klasse A EU-Richtlinie zur Elektromagneti...
Page 218 - ENERGY STAR model information; ENERGY STAR
ENERGY STAR model information ENERGY STAR ® is a joint program of the U.S. Environmental Protection Agency and the U.S. Department of Energy aimed at saving money and protecting the environment through energy efficient products andpractices. Lenovo is proud to offer our customers products with an EN...
Page 219 - Index
Index 2.5-inch hot-swap hard-disk-drive backplane locations 42 3.5-inch hot-swap hard-disk-drive backplane locations 40 A about RAID 72 Advanced menu Setup Utility program 62 advanced SATA/SAS hardware RAID configuring 79 ambient temperature limit LED 21 B BIOS and TMM update software 13 Boot Manage...