Lennox Lennox Air Handler - Manual

Lennox Lennox Air Handler

Lennox Lennox Air Handler – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
Page: / 16

Table of Contents:

  • Page 3 – Requirements; WARNING; NOTES —; Installation Clearances; NON-DUCTED RETURN CLOSET INSTALLATION
  • Page 4 – Installation; IMPORTANT
  • Page 5 – RIGHT-HAND AIR DISCHARGE; Figure 4. Remove Main Drain Pan Mounting Bracket; Figure 5. Remove Horizontal and Main Drain Pan
  • Page 6 – Condensate Drain; Figure 9. Typical Main and Overflow Drain
  • Page 7 – Duct System and Filters; Model
  • Page 8 – INSTALLING DUCT SYSTEM; Connecting Refrigerant Lines; NOTE — Do not use soft solder.; Sealing the Unit
  • Page 9 – Electrical Connections; Electric Shock Hazard.; USE COPPER CONDUCTORS ONLY; GND; Using the wiring diagram located on the unit access
  • Page 10 – Airflow — Cooling Blower Speed; CHANGE BLOWER SPEED; Locate pin number 2 on the blower relay. Two black
  • Page 11 – CHANGING BLOWER SPEED; Figure 13. Changing Blower Speed; All data given while air handler is operating with a dry DX coil.
  • Page 12 – Motor ramps down to stop.
  • Page 13 – on the thermostat. They may also be; Maintenance; Cabinet Insulation; REPAIRING DAMAGED INSULATION
Loading the manual

10/2012

506757-01

(0659371-80)

*2P102012*

*P506757-01*

Page 1

E

2012 Lennox Industries Inc.

Dallas, Texas, USA

THIS MANUAL MUST BE LEFT WITH THE

HOMEOWNER FOR FUTURE REFERENCE

WARNING

Improper installation, adjustment, alteration, service or
maintenance can cause personal injury, loss of life, or
damage to property.

Installation and service must be performed by a licensed
professional installer (or equivalent) or a service agency.

IMPORTANT

The Clean Air Act of 1990 bans the intentional venting of
refrigerant (CFCs, HCFCs and HFCs) as of July 1, 1992.
Approved methods of recovery, recycling or reclaiming
must be followed. Fines and/or incarceration may be
levied for noncompliance.

WARNING

The State of California has determined that this product
may contain or produce a chemical or chemicals, in very
low doses, which may cause serious illness or death. It
may also cause cancer, birth defects, or reproductive
harm.

INSTALLATION
INSTRUCTIONS

Merit

®

CBX25UH Series

Units

AIR HANDLERS

506757-01 (0659371-80)
10/2012

Table of Contents

Shipping and Packing List

1

. . . . . . . . . . . . . . . . . . . . . .

CBX25UH Series Units

1

. . . . . . . . . . . . . . . . . . . . . . . . .

Requirements

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Installation Clearances

3

. . . . . . . . . . . . . . . . . . . . . . . . .

Installation

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Condensate Drain

6

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Duct System and Filters

7

. . . . . . . . . . . . . . . . . . . . . . . .

Connecting Refrigerant Lines

8

. . . . . . . . . . . . . . . . . . .

Sealing the Unit

8

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Electrical Connections

9

. . . . . . . . . . . . . . . . . . . . . . . . .

Airflow - Cooling Blower Speed

10

. . . . . . . . . . . . . . . . . .

Check-Out Procedures

12

. . . . . . . . . . . . . . . . . . . . . . . . .

Operation

12

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Maintenance

13

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Cabinet Insulation

13

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Shipping and Packing List

Package 1 of 1 contains the following:

1 - Assembled air handler unit for upflow or horizontal air

discharge application (includes upflow and horizontal
drain pans and

pre-installed air filter

).

Check equipment for shipping damage. If found,
immediately report damage to the last carrier. Check the
unit rating plate to confirm that delivered unit matches
order.

General

The CBX25UH air handler is designed for indoor
installation only. As shipped, the unit is ready for
installation in either upflow, horizontal left-hand and
right-hand air discharge applications. Electric heat, down
flow air discharge application kits, air filters and other
various accessories are available and listed in the

CBX25UH Product Specification bulletin

for ordering

.

All units come with a factory installed check/expansion
valve.

Litho U.S.A.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 3 - Requirements; WARNING; NOTES —; Installation Clearances; NON-DUCTED RETURN CLOSET INSTALLATION

Page 3 CBX25UH SERIES Requirements WARNING Excessive Weight Hazard - Use two or more peoplewhen moving and installing the unit. Failure to do so canresult in back or other type of injury. IMPORTANT The CBX25UH units are designed to match, and must beused with, outdoor units as rated. The indoor sect...

Page 4 - Installation; IMPORTANT

Page 4 If a return air plenum is used, the return air grille should beimmediately in front of the opening in the plenum to allowfor the free flow of return air. When not installed in front ofthe opening, there must be adequate clearance around theair handler to allow for the free flow of return air....

Page 5 - RIGHT-HAND AIR DISCHARGE; Figure 4. Remove Main Drain Pan Mounting Bracket; Figure 5. Remove Horizontal and Main Drain Pan

Page 5 CBX25UH SERIES 5. If the unit is suspended, the entire length of the cabinet must be supported. If you use a chain or strap, use apiece of angle iron or sheet metal attached to the unit(either above or below) to support the length of thecabinet. Use securing screws no longer than 1/2 inchto a...

Other Lennox Models

All Lennox Other